Liquid Analysis

Conductivity Meter for Water

Engineered for Accurate Daily Water Analysis

Instrava Conductivity Meter for Water is designed for precise and efficient multi-parameter measurement in compact laboratory and educational environments.

With high-resolution detection from 0.0000 mS/cm up to 400.0 mS/cm, automatic range switching, HOLD auto-lock function, and temperature offset adjustment, the instrument delivers stable and repeatable measurement results.

Its compact structural design saves workspace while maintaining professional-level analytical performance.

Reliable, intuitive, and engineered for daily laboratory testing.

  وصف مفتاح تبديل مستوى السائل  

Conductivity Meter for Water-Applicable Scenarios

Instrava Conductivity Meter is suitable for:

  • Laboratory routine water analysis

  • School and university teaching laboratories

  • Environmental water testing

  • Aquaculture salinity monitoring

  • Industrial process water inspection

  • Quality control in food and beverage production

Designed for users requiring precision with operational simplicity.

Electrical conductivity meter, suitable for liquid conductivity testing.
pH conductivity meter with a display screen and control buttons, suitable for various water quality measurements.

Conductivity Meter for Water-Engineering Advantages

High-Resolution Multi-Parameter Capability

Supports:

  • Conductivity (EC)

  • إجمالي المواد الصلبة الذائبة (TDS)

  • Salinity

  • درجة الحرارة

Integrated measurement platform improves workflow efficiency.

نطاق قياس واسع

  • EC: 0.0000 – 400.0 mS/cm

  • TDS: 0.0000 ppm – 200.0 ppt

  • Salinity: 0.0 – 260.0 g/L

  • Temperature: -10.0 – 110.0°C

Covers ultrapure water through high-salinity industrial solutions.

Automatic Range Switching

The instrument automatically selects the optimal measurement range, ensuring:

  • Improved readability

  • Reduced manual configuration

  • Higher measurement reliability

Suitable for users with varying testing requirements.

Intelligent HOLD & Stability Lock

  • HOLD auto-lock captures stable readings

  • Calibrated point display ensures calibration visibility

  • Clear, easy-to-read data interface

Enhances repeatability and reduces reading error.

Temperature Compensation & Offset Adjustment

  • Automatic temperature compensation

  • Manual temperature offset adjustment

Ensures improved accuracy across different sample conditions.

Compact and Anti-Interference Design

  • Exquisite and space-saving structure

  • High-brightness backlight

  • Excellent anti-interference circuit design

  • Lightweight and portable

Optimized for desktop laboratory use and mobile testing.

Data Management

  • Stores up to 256 sets of measurement data

  • Multiple data recall capability

Supports structured documentation for daily testing.

  معلمة مفتاح تبديل مستوى السائل  

Conductivity Meter for Water-Technical Specifications

Conductivity (EC)

المعلمةالمواصفات
النطاق0.0000 – 400.0 mS/cm

TDS

المعلمةالمواصفات
النطاق0.0000 ppm – 200.0 ppt

Salinity

المعلمةالمواصفات
النطاق0.0 – 260.0 g/L

درجة الحرارة

المعلمةالمواصفات
النطاق-10.0 – 110.0°C

System Parameters

المعلمةالمواصفات
Data Storage256 groups
OperationSimple key operation
العرضHigh-brightness backlight screen
Working Environment-5°C – 60°C
الرطوبة< 90% RH

Designed for Reliable Everyday Measurement

Instrava Conductivity Meter for Water delivers stable multi-parameter analysis in a compact, easy-to-operate platform.

Whether used in laboratories, classrooms, or quality inspection environments, it provides accurate conductivity and salinity measurement with minimal setup complexity.

Instrava — Engineered for Practical Precision.

  إنسترافا OEM/ODM

دعم الهندسة والتخصيص من إنسترافا

في Instrava، يتم تطوير أدواتنا مع التركيز القوي على التطبيقات الصناعية الحقيقية. تم تصميم كل منتج ليعمل كعنصر موثوق به ضمن أنظمة القياس والتحكم والأتمتة، وليس كجهاز مستقل.

يقوم فريقنا الهندسي بدعم العملاء أثناء اختيار المنتج من خلال تقييم ظروف المعالجة وبيئات التشغيل ومتطلبات النظام، مما يضمن أداءً مستقرًا وطويل الأجل في الاستخدام الفعلي.

وبالإضافة إلى التكوينات القياسية، تقدم Instrava خيارات تخصيص مرنة، بما في ذلك نطاق القياس والمواد وإشارات الخرج وواجهات الاتصال وطرق التركيب. تم تصميم جميع الحلول المخصصة لتلبية المعايير الصناعية والمتطلبات الخاصة بالتطبيقات.

نحن ندعم أيضًا مشاريع تصنيع المعدات الأصلية وتكامل الأنظمة، ونوفر تصميمًا متسقًا للمنتجات، ووثائق فنية، وتوريدًا طويل الأجل لضمان التكامل السلس والتشغيل الموثوق به طوال دورة حياة المشروع.

ترمز إلى الثقة وبداية شراكة طويلة الأمد

  توصيات المنتجات ذات الصلة  

Automatic range switching is based on dynamic signal amplitude detection.

The instrument continuously evaluates electrode output voltage and automatically selects the optimal amplification range.

This ensures:

  • Maximum resolution within each measurement interval

  • Prevention of signal saturation

  • Reduced manual intervention

The result is consistent readability and improved measurement reliability across low and high conductivity samples.

Conductivity measurement is sensitive to electromagnetic noise and environmental fluctuations.

Instrava integrates:

  • Optimized shielding layout

  • Stable analog front-end circuitry

  • Digital signal filtering algorithms

  • Temperature-stabilized compensation logic

These elements reduce electrical noise influence, ensuring stable readings in laboratory and teaching environments.

At elevated conductivity levels, ion interaction increases and electrode polarization effects become more pronounced.

This may cause slight non-linear response characteristics, particularly near the upper measurement limits.

Automatic range optimization and calibrated slope correction minimize high-range deviation, maintaining ±1% FS performance under normal operating conditions.

The instrument applies a linear temperature compensation model by default, correcting conductivity values relative to a reference temperature.

Since ionic mobility increases with temperature, compensation ensures measurement comparability across varying sample conditions.

Manual temperature offset adjustment further refines measurement alignment when testing specialized solutions.

The HOLD auto-lock function detects endpoint stabilization before freezing the displayed value.

This prevents premature reading capture and improves repeatability during teaching demonstrations or routine lab workflows.

High resolution allows students and laboratory users to observe small conductivity variations during experiments.

This enhances understanding of dilution curves, ionic strength changes, and solution preparation accuracy.

It also enables early-stage contamination detection in low-conductivity samples.

لماذا تختار إنسترافا

باختيارك Instrava، ستحصل على شريك يتمتع بفهم عميق للتطبيقات الصناعية والخبرة اللازمة لمواجهة التحديات التشغيلية الحالية.
يمتد دورنا إلى ما هو أبعد من المنتجات - فنحن ندعم نجاحك من خلال حلول يمكن الاعتماد عليها والتزام طويل الأجل.

الابتكار المدفوع بالهندسة

يسترشد الابتكار في Instrava بالمتطلبات الصناعية الحقيقية. نحن نعمل باستمرار على تحسين تقنياتنا لمعالجة التحديات التشغيلية المتطورة، مما يضمن أداءً عمليًا وموثوقًا في البيئات الصعبة.

التخصيص الخاص بالتطبيق الخاص بالتطبيق

نحن نقدم التخصيص على المستوى الهندسي لمطابقة ظروف عملية محددة. بدءًا من نطاق القياس والمواد إلى إشارات الخرج وخيارات التثبيت، يتم تكوين حلولنا لتناسب التطبيقات الحقيقية.

جودة وموثوقية مثبتة

الجودة والموثوقية أمران أساسيان لكل منتج من منتجات إنسترافا. تُصنع أدواتنا تحت رقابة صارمة على الجودة ويتم اختبارها بدقة، وتوفر أداءً دقيقًا ومستقرًا وطويل الأجل.

القدرة العالمية مع الدعم المحلي

تجمع إنسترافا بين الخبرة الهندسية العالمية والدعم المحلي سريع الاستجابة، مما يضمن لشركائنا الاستفادة من التكنولوجيا المتوافقة دوليًا والخدمة الإقليمية في الوقت المناسب.

محفظة المنتجات الشاملة

تتيح لنا محفظتنا الواسعة من أدوات القياس والتحكم تلبية مجموعة واسعة من الاحتياجات الصناعية، مما يوفر حلولاً متكاملة من مصدر واحد وموثوق.

الدعم الهندسي الموجه للشركاء

نحن نعمل عن كثب مع شركائنا بدءاً من الاستشارات الفنية وحتى دعم ما بعد البيع. ينصب تركيزنا على تقديم حلول تخلق قيمة دائمة وتدعم النجاح التشغيلي على المدى الطويل.

Thermal vs Vortex vs Differential Pressure: How to Choose the Right Flow Measurement Technology

  • بواسطة إنسترافا
  • فبراير 25, 2026

Selecting a flow meter is rarely about accuracy alone. In industrial applications, the real challenges include: Variable flow rates Pressure...

  • 43دقيقة للقراءة

مقياس تدفق التروس البيضاوي: لماذا لا يزال يهيمن على قياس التدفق عالي اللزوجة في الأتمتة الحديثة

  • بواسطة إنسترافا
  • يناير 28, 2026

الثبات الهادئ لمقاييس تدفق التروس البيضاوية في عصر تهيمن فيه أجهزة الاستشعار الذكية والتوائم الرقمية والأجهزة التي تعتمد على الذكاء الاصطناعي...

  • 2قراءة 2 دقيقة

أجهزة قياس التدفق المحمولة بالموجات فوق الصوتية - قياس التدفق الصناعي الدقيق

  • بواسطة إنسترافا
  • يناير 22, 2026

عدادات التدفق المحمولة بالموجات فوق الصوتية - قياس التدفق الصناعي الدقيق | إنسترافا عدادات التدفق المحمولة بالموجات فوق الصوتية نظرة عامة عدادات التدفق المحمولة بالموجات فوق الصوتية...

  • قراءة 40 دقيقة
الصفحة الرئيسية
المنتجات
واتس آب