{"id":30560,"date":"2026-01-06T13:52:08","date_gmt":"2026-01-06T13:52:08","guid":{"rendered":"https:\/\/instrava.com\/?p=30560"},"modified":"2026-01-07T03:00:18","modified_gmt":"2026-01-07T03:00:18","slug":"indicador-de-nivel-magnetico-vs-indicador-de-nivel-radar-una-comparacion-exhaustiva","status":"publish","type":"post","link":"https:\/\/instrava.com\/es\/indicador-de-nivel-magnetico-vs-indicador-de-nivel-radar-una-comparacion-exhaustiva\/","title":{"rendered":"Medidor de nivel magn\u00e9tico frente a medidor de nivel por radar: Una comparaci\u00f3n exhaustiva"},"content":{"rendered":"<h2 data-start=\"227\" data-end=\"246\"><strong data-start=\"230\" data-end=\"246\">Introducci\u00f3n<\/strong><\/h2>\n<p data-start=\"248\" data-end=\"489\">Los indicadores de nivel magn\u00e9ticos y los indicadores de nivel por radar son dos de las tecnolog\u00edas m\u00e1s fiables para la medici\u00f3n industrial del nivel de l\u00edquidos. Ambas tienen ventajas \u00fanicas, pero est\u00e1n dise\u00f1adas para condiciones de proceso y requisitos de medici\u00f3n diferentes.<\/p>\n<p data-start=\"491\" data-end=\"766\">Desde la perspectiva de un fabricante, la selecci\u00f3n del indicador de nivel adecuado implica la evaluaci\u00f3n de los par\u00e1metros del proceso, las limitaciones de la instalaci\u00f3n y la fiabilidad a largo plazo. Este art\u00edculo ofrece una comparaci\u00f3n detallada para ayudar a los ingenieros y operarios de planta a realizar la selecci\u00f3n m\u00e1s informada.<\/p>\n<hr data-start=\"768\" data-end=\"771\" \/>\n<h2 data-start=\"773\" data-end=\"797\"><strong data-start=\"776\" data-end=\"797\">Principio de funcionamiento<\/strong><\/h2>\n<h3 data-start=\"799\" data-end=\"827\"><strong data-start=\"803\" data-end=\"827\">Medidor de nivel magn\u00e9tico<\/strong><\/h3>\n<p data-start=\"829\" data-end=\"1127\">A <a href=\"https:\/\/instrava.com\/product\/magnetic-level-oil-gas-storage-tank\/\"><strong>indicador magn\u00e9tico de nivel<\/strong><\/a> utiliza un flotador que contiene un im\u00e1n que sube y baja con el nivel del l\u00edquido dentro de una c\u00e1mara sellada. El movimiento del flotador acciona un indicador magn\u00e9tico externo o una pantalla para mostrar el nivel en tiempo real. Proporciona indicaci\u00f3n visual directa y salida electr\u00f3nica opcional.<\/p>\n<ul data-start=\"1129\" data-end=\"1210\">\n<li data-start=\"1129\" data-end=\"1157\">\n<p data-start=\"1131\" data-end=\"1157\">Medici\u00f3n por contacto<\/p>\n<\/li>\n<li data-start=\"1158\" data-end=\"1189\">\n<p data-start=\"1160\" data-end=\"1189\">Ideal para el control visual<\/p>\n<\/li>\n<li data-start=\"1190\" data-end=\"1210\">\n<p data-start=\"1192\" data-end=\"1210\">Bajo riesgo de fracaso<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1212\" data-end=\"1215\" \/>\n<h3 data-start=\"1217\" data-end=\"1242\"><strong data-start=\"1221\" data-end=\"1242\">Medidor de nivel de radar<\/strong><\/h3>\n<p data-start=\"1244\" data-end=\"1434\"><a href=\"https:\/\/instrava.com\/product\/radar-level-gauges\/\"><strong>Indicadores de nivel radar<\/strong><\/a> utilizan ondas electromagn\u00e9ticas de microondas para medir la distancia a la superficie del l\u00edquido. El tiempo de vuelo de la se\u00f1al reflejada se convierte en una lectura de nivel continua.<\/p>\n<ul data-start=\"1436\" data-end=\"1552\">\n<li data-start=\"1436\" data-end=\"1463\">\n<p data-start=\"1438\" data-end=\"1463\">Medici\u00f3n sin contacto<\/p>\n<\/li>\n<li data-start=\"1464\" data-end=\"1519\">\n<p data-start=\"1466\" data-end=\"1519\">Resistente a la temperatura, la presi\u00f3n, la espuma y el vapor<\/p>\n<\/li>\n<li data-start=\"1520\" data-end=\"1552\">\n<p data-start=\"1522\" data-end=\"1552\">Requiere un mantenimiento m\u00ednimo<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1554\" data-end=\"1557\" \/>\n<h2 data-start=\"1559\" data-end=\"1588\"><strong data-start=\"1562\" data-end=\"1588\">Comparaci\u00f3n de resultados<\/strong><\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1590\" data-end=\"2203\">\n<thead data-start=\"1590\" data-end=\"1644\">\n<tr data-start=\"1590\" data-end=\"1644\">\n<th data-start=\"1590\" data-end=\"1600\" data-col-size=\"sm\">Caracter\u00edstica<\/th>\n<th data-start=\"1600\" data-end=\"1623\" data-col-size=\"sm\">Medidor de nivel magn\u00e9tico<\/th>\n<th data-start=\"1623\" data-end=\"1644\" data-col-size=\"sm\">Medidor de nivel de radar<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1695\" data-end=\"2203\">\n<tr data-start=\"1695\" data-end=\"1739\">\n<td data-start=\"1695\" data-end=\"1714\" data-col-size=\"sm\">Tipo de medici\u00f3n<\/td>\n<td data-col-size=\"sm\" data-start=\"1714\" data-end=\"1724\">P\u00f3ngase en contacto con<\/td>\n<td data-col-size=\"sm\" data-start=\"1724\" data-end=\"1739\">Sin contacto<\/td>\n<\/tr>\n<tr data-start=\"1740\" data-end=\"1800\">\n<td data-start=\"1740\" data-end=\"1760\" data-col-size=\"sm\">Indicaci\u00f3n visual<\/td>\n<td data-col-size=\"sm\" data-start=\"1760\" data-end=\"1766\">S\u00ed<\/td>\n<td data-col-size=\"sm\" data-start=\"1766\" data-end=\"1800\">Opcional con pantalla externa<\/td>\n<\/tr>\n<tr data-start=\"1801\" data-end=\"1867\">\n<td data-start=\"1801\" data-end=\"1812\" data-col-size=\"sm\">Precisi\u00f3n<\/td>\n<td data-col-size=\"sm\" data-start=\"1812\" data-end=\"1840\">Alta para la supervisi\u00f3n local<\/td>\n<td data-col-size=\"sm\" data-start=\"1840\" data-end=\"1867\">Alta para todas las condiciones<\/td>\n<\/tr>\n<tr data-start=\"1868\" data-end=\"1912\">\n<td data-start=\"1868\" data-end=\"1892\" data-col-size=\"sm\">Tolerancia t\u00e9rmica<\/td>\n<td data-col-size=\"sm\" data-start=\"1892\" data-end=\"1899\">Bien<\/td>\n<td data-col-size=\"sm\" data-start=\"1899\" data-end=\"1912\">Excelente<\/td>\n<\/tr>\n<tr data-start=\"1913\" data-end=\"1954\">\n<td data-start=\"1913\" data-end=\"1934\" data-col-size=\"sm\">Tolerancia de presi\u00f3n<\/td>\n<td data-col-size=\"sm\" data-start=\"1934\" data-end=\"1941\">Bien<\/td>\n<td data-col-size=\"sm\" data-start=\"1941\" data-end=\"1954\">Excelente<\/td>\n<\/tr>\n<tr data-start=\"1955\" data-end=\"2037\">\n<td data-start=\"1955\" data-end=\"1973\" data-col-size=\"sm\">Medios corrosivos<\/td>\n<td data-col-size=\"sm\" data-start=\"1973\" data-end=\"2003\">Requiere selecci\u00f3n de material<\/td>\n<td data-col-size=\"sm\" data-start=\"2003\" data-end=\"2037\">Excelente soluci\u00f3n sin contacto<\/td>\n<\/tr>\n<tr data-start=\"2038\" data-end=\"2070\">\n<td data-start=\"2038\" data-end=\"2052\" data-col-size=\"sm\">Mantenimiento<\/td>\n<td data-col-size=\"sm\" data-start=\"2052\" data-end=\"2058\">Bajo<\/td>\n<td data-col-size=\"sm\" data-start=\"2058\" data-end=\"2070\">Muy bajo<\/td>\n<\/tr>\n<tr data-start=\"2071\" data-end=\"2136\">\n<td data-start=\"2071\" data-end=\"2091\" data-col-size=\"sm\">Requisitos de potencia<\/td>\n<td data-col-size=\"sm\" data-start=\"2091\" data-end=\"2106\">No es necesario<\/td>\n<td data-col-size=\"sm\" data-start=\"2106\" data-end=\"2136\">Necesario para la salida de se\u00f1al<\/td>\n<\/tr>\n<tr data-start=\"2137\" data-end=\"2203\">\n<td data-start=\"2137\" data-end=\"2157\" data-col-size=\"sm\">Control remoto<\/td>\n<td data-col-size=\"sm\" data-start=\"2157\" data-end=\"2168\">Opcional<\/td>\n<td data-col-size=\"sm\" data-start=\"2168\" data-end=\"2203\">Salida est\u00e1ndar (4-20 mA, HART)<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<hr data-start=\"2205\" data-end=\"2208\" \/>\n<h2 data-start=\"2210\" data-end=\"2240\"><strong data-start=\"2213\" data-end=\"2240\">Comparaci\u00f3n de instalaciones<\/strong><\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2242\" data-end=\"2671\">\n<thead data-start=\"2242\" data-end=\"2308\">\n<tr data-start=\"2242\" data-end=\"2308\">\n<th data-start=\"2242\" data-end=\"2264\" data-col-size=\"sm\">Factor de instalaci\u00f3n<\/th>\n<th data-start=\"2264\" data-end=\"2287\" data-col-size=\"sm\">Medidor de nivel magn\u00e9tico<\/th>\n<th data-start=\"2287\" data-end=\"2308\" data-col-size=\"sm\">Medidor de nivel de radar<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2371\" data-end=\"2671\">\n<tr data-start=\"2371\" data-end=\"2429\">\n<td data-start=\"2371\" data-end=\"2391\" data-col-size=\"sm\">Posici\u00f3n de montaje<\/td>\n<td data-col-size=\"sm\" data-start=\"2391\" data-end=\"2414\">Montaje lateral en el dep\u00f3sito<\/td>\n<td data-col-size=\"sm\" data-start=\"2414\" data-end=\"2429\">Montaje superior<\/td>\n<\/tr>\n<tr data-start=\"2430\" data-end=\"2487\">\n<td data-start=\"2430\" data-end=\"2447\" data-col-size=\"sm\">Contacto medio<\/td>\n<td data-col-size=\"sm\" data-start=\"2447\" data-end=\"2473\">Flotador en contacto directo<\/td>\n<td data-col-size=\"sm\" data-start=\"2473\" data-end=\"2487\">Sin contacto<\/td>\n<\/tr>\n<tr data-start=\"2488\" data-end=\"2556\">\n<td data-start=\"2488\" data-end=\"2508\" data-col-size=\"sm\">Obstrucciones del dep\u00f3sito<\/td>\n<td data-col-size=\"sm\" data-start=\"2508\" data-end=\"2523\">No afectados<\/td>\n<td data-col-size=\"sm\" data-start=\"2523\" data-end=\"2556\">Debe evitar los obst\u00e1culos internos<\/td>\n<\/tr>\n<tr data-start=\"2557\" data-end=\"2620\">\n<td data-start=\"2557\" data-end=\"2582\" data-col-size=\"sm\">Acceso para mantenimiento<\/td>\n<td data-col-size=\"sm\" data-start=\"2582\" data-end=\"2601\">F\u00e1cil acceso lateral<\/td>\n<td data-col-size=\"sm\" data-start=\"2601\" data-end=\"2620\">F\u00e1cil acceso superior<\/td>\n<\/tr>\n<tr data-start=\"2621\" data-end=\"2671\">\n<td data-start=\"2621\" data-end=\"2630\" data-col-size=\"sm\">Cableado<\/td>\n<td data-col-size=\"sm\" data-start=\"2630\" data-end=\"2641\">Opcional<\/td>\n<td data-col-size=\"sm\" data-start=\"2641\" data-end=\"2671\">Necesario para la salida de se\u00f1al<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<hr data-start=\"2673\" data-end=\"2676\" \/>\n<h2 data-start=\"2678\" data-end=\"2705\"><strong data-start=\"2681\" data-end=\"2705\">Aplicaciones t\u00edpicas<\/strong><\/h2>\n<h3 data-start=\"2707\" data-end=\"2748\"><strong data-start=\"2711\" data-end=\"2748\">Aplicaciones del medidor de nivel magn\u00e9tico<\/strong><\/h3>\n<ul data-start=\"2750\" data-end=\"2898\">\n<li data-start=\"2750\" data-end=\"2778\">\n<p data-start=\"2752\" data-end=\"2778\">Calderas de alta temperatura<\/p>\n<\/li>\n<li data-start=\"2779\" data-end=\"2809\">\n<p data-start=\"2781\" data-end=\"2809\">Dep\u00f3sitos qu\u00edmicos presurizados<\/p>\n<\/li>\n<li data-start=\"2810\" data-end=\"2842\">\n<p data-start=\"2812\" data-end=\"2842\">Medios corrosivos o peligrosos<\/p>\n<\/li>\n<li data-start=\"2843\" data-end=\"2898\">\n<p data-start=\"2845\" data-end=\"2898\">Procesos cr\u00edticos para la seguridad que requieren supervisi\u00f3n visual<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2900\" data-end=\"2938\"><strong data-start=\"2904\" data-end=\"2938\">Aplicaciones del medidor de nivel radar<\/strong><\/h3>\n<ul data-start=\"2940\" data-end=\"3092\">\n<li data-start=\"2940\" data-end=\"2963\">\n<p data-start=\"2942\" data-end=\"2963\">Grandes tanques de almacenamiento<\/p>\n<\/li>\n<li data-start=\"2964\" data-end=\"3004\">\n<p data-start=\"2966\" data-end=\"3004\">Dep\u00f3sitos con vapor, espuma o agitaci\u00f3n<\/p>\n<\/li>\n<li data-start=\"3005\" data-end=\"3050\">\n<p data-start=\"3007\" data-end=\"3050\">Recipientes de alta presi\u00f3n o alta temperatura<\/p>\n<\/li>\n<li data-start=\"3051\" data-end=\"3092\">\n<p data-start=\"3053\" data-end=\"3092\">Supervisi\u00f3n remota mediante sistemas de control<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"3094\" data-end=\"3097\" \/>\n<h2 data-start=\"3099\" data-end=\"3145\"><strong data-start=\"3102\" data-end=\"3145\">Recomendaci\u00f3n de selecci\u00f3n del fabricante<\/strong><\/h2>\n<p data-start=\"3147\" data-end=\"3186\">Desde la perspectiva de un fabricante OEM:<\/p>\n<ul data-start=\"3188\" data-end=\"3523\">\n<li data-start=\"3188\" data-end=\"3373\">\n<p data-start=\"3190\" data-end=\"3373\"><strong data-start=\"3190\" data-end=\"3215\">Indicadores magn\u00e9ticos de nivel<\/strong> son ideales para procesos que requieren <strong data-start=\"3253\" data-end=\"3310\">indicaci\u00f3n visual directa, sencillez y fiabilidad<\/strong>, especialmente en entornos con disponibilidad limitada de energ\u00eda.<\/p>\n<\/li>\n<li data-start=\"3374\" data-end=\"3523\">\n<p data-start=\"3376\" data-end=\"3523\"><strong data-start=\"3376\" data-end=\"3398\">Indicadores de nivel radar<\/strong> se prefieren para <strong data-start=\"3417\" data-end=\"3471\">aplicaciones de medici\u00f3n complejas, dif\u00edciles o remotas<\/strong>, proporcionando una gran precisi\u00f3n y un mantenimiento m\u00ednimo.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3525\" data-end=\"3676\">La selecci\u00f3n del indicador de nivel adecuado suele implicar consultar a los fabricantes para determinar los materiales adecuados, el rango de medici\u00f3n y la configuraci\u00f3n de la instalaci\u00f3n.<\/p>\n<hr data-start=\"3678\" data-end=\"3681\" \/>\n<h2 data-start=\"3683\" data-end=\"3700\"><strong data-start=\"3686\" data-end=\"3700\">Conclusi\u00f3n<\/strong><\/h2>\n<p data-start=\"3702\" data-end=\"3979\">Tanto los indicadores de nivel magn\u00e9ticos como los de radar son soluciones probadas para la medici\u00f3n de nivel industrial. Los indicadores de nivel magn\u00e9ticos ofrecen supervisi\u00f3n visual directa y simplicidad, mientras que los indicadores de nivel de radar destacan en entornos duros o exigentes que requieren alta precisi\u00f3n y fiabilidad a largo plazo.<\/p>\n<p data-start=\"3981\" data-end=\"4106\">Consultar con fabricantes experimentados garantiza una selecci\u00f3n adecuada, un rendimiento \u00f3ptimo y una estabilidad operativa a largo plazo.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Magnetic level gauges and radar level gauges are two of the most reliable technologies for industrial liquid level measurement. Both have unique advantages, but they are designed for different process conditions and measurement requirements. From a manufacturer\u2019s perspective, selecting the right level gauge involves evaluating process parameters, installation constraints, and long-term reliability. This article&#8230;<\/p>","protected":false},"author":1,"featured_media":30566,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[295],"tags":[310,332,324,331,325,330,307,309],"class_list":["post-30560","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-level-gauge","tag-4-20ma-signal","tag-atex","tag-ce","tag-intrinsically-safe","tag-rohs","tag-selection-guide","tag-ultrasonic","tag-working-principle"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Magnetic Level Gauge vs Radar Level Gauge - Instrava<\/title>\n<meta name=\"description\" content=\"Compare magnetic and radar level gauges and see how OEM manufacturers select the right solution for reliable industrial level measurement.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrava.com\/es\/indicador-de-nivel-magnetico-vs-indicador-de-nivel-radar-una-comparacion-exhaustiva\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Magnetic Level Gauge vs Radar Level Gauge - Instrava\" \/>\n<meta property=\"og:description\" content=\"Compare magnetic and radar level gauges and see how OEM manufacturers select the right solution for reliable industrial level measurement.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrava.com\/es\/indicador-de-nivel-magnetico-vs-indicador-de-nivel-radar-una-comparacion-exhaustiva\/\" \/>\n<meta property=\"og:site_name\" content=\"Instrava\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-06T13:52:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-07T03:00:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/guided-wave-radar-level-sensor.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Instrava\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Instrava\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/\"},\"author\":{\"name\":\"Instrava\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\"},\"headline\":\"Magnetic Level Gauge vs Radar Level Gauge: A Comprehensive Comparison\",\"datePublished\":\"2026-01-06T13:52:08+00:00\",\"dateModified\":\"2026-01-07T03:00:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/\"},\"wordCount\":460,\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/guided-wave-radar-level-sensor.webp\",\"keywords\":[\"4\u201320mA Signal\",\"ATEX\",\"CE\",\"Intrinsically Safe\",\"RoHS\",\"Selection Guide\",\"Ultrasonic\",\"Working Principle\"],\"articleSection\":[\"Level Gauge\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/\",\"name\":\"Magnetic Level Gauge vs Radar Level Gauge - Instrava\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/guided-wave-radar-level-sensor.webp\",\"datePublished\":\"2026-01-06T13:52:08+00:00\",\"dateModified\":\"2026-01-07T03:00:18+00:00\",\"description\":\"Compare magnetic and radar level gauges and see how OEM manufacturers select the right solution for reliable industrial level measurement.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/guided-wave-radar-level-sensor.webp\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/guided-wave-radar-level-sensor.webp\",\"width\":1200,\"height\":650,\"caption\":\"Guided wave radar level sensor testing in industrial application Industrial radar level transmitter measurement and calibration\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrava.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Level Gauge\",\"item\":\"https:\\\/\\\/instrava.com\\\/category\\\/level-gauge\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Magnetic Level Gauge vs Radar Level Gauge: A Comprehensive Comparison\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"name\":\"instrava.com\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrava.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\",\"name\":\"instrava.com\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"width\":288,\"height\":59,\"caption\":\"instrava.com\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\",\"name\":\"Instrava\",\"sameAs\":[\"https:\\\/\\\/instrava.com\"],\"url\":\"https:\\\/\\\/instrava.com\\\/es\\\/author\\\/matrinpolergmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Medidor de nivel magn\u00e9tico vs Medidor de nivel radar - Instrava","description":"Compare los indicadores de nivel magn\u00e9ticos y de radar y vea c\u00f3mo los fabricantes de equipos originales seleccionan la soluci\u00f3n adecuada para una medici\u00f3n fiable del nivel industrial.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrava.com\/es\/indicador-de-nivel-magnetico-vs-indicador-de-nivel-radar-una-comparacion-exhaustiva\/","og_locale":"es_ES","og_type":"article","og_title":"Magnetic Level Gauge vs Radar Level Gauge - Instrava","og_description":"Compare magnetic and radar level gauges and see how OEM manufacturers select the right solution for reliable industrial level measurement.","og_url":"https:\/\/instrava.com\/es\/indicador-de-nivel-magnetico-vs-indicador-de-nivel-radar-una-comparacion-exhaustiva\/","og_site_name":"Instrava","article_published_time":"2026-01-06T13:52:08+00:00","article_modified_time":"2026-01-07T03:00:18+00:00","og_image":[{"width":1200,"height":650,"url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/guided-wave-radar-level-sensor.webp","type":"image\/webp"}],"author":"Instrava","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Instrava","Tiempo de lectura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/#article","isPartOf":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/"},"author":{"name":"Instrava","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6"},"headline":"Magnetic Level Gauge vs Radar Level Gauge: A Comprehensive Comparison","datePublished":"2026-01-06T13:52:08+00:00","dateModified":"2026-01-07T03:00:18+00:00","mainEntityOfPage":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/"},"wordCount":460,"publisher":{"@id":"https:\/\/instrava.com\/#organization"},"image":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/guided-wave-radar-level-sensor.webp","keywords":["4\u201320mA Signal","ATEX","CE","Intrinsically Safe","RoHS","Selection Guide","Ultrasonic","Working Principle"],"articleSection":["Level Gauge"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/","url":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/","name":"Medidor de nivel magn\u00e9tico vs Medidor de nivel radar - Instrava","isPartOf":{"@id":"https:\/\/instrava.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/#primaryimage"},"image":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/guided-wave-radar-level-sensor.webp","datePublished":"2026-01-06T13:52:08+00:00","dateModified":"2026-01-07T03:00:18+00:00","description":"Compare los indicadores de nivel magn\u00e9ticos y de radar y vea c\u00f3mo los fabricantes de equipos originales seleccionan la soluci\u00f3n adecuada para una medici\u00f3n fiable del nivel industrial.","breadcrumb":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/#primaryimage","url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/guided-wave-radar-level-sensor.webp","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/guided-wave-radar-level-sensor.webp","width":1200,"height":650,"caption":"Guided wave radar level sensor testing in industrial application Industrial radar level transmitter measurement and calibration"},{"@type":"BreadcrumbList","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-radar-level-gauge-a-comprehensive-comparison\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrava.com\/"},{"@type":"ListItem","position":2,"name":"Level Gauge","item":"https:\/\/instrava.com\/category\/level-gauge\/"},{"@type":"ListItem","position":3,"name":"Magnetic Level Gauge vs Radar Level Gauge: A Comprehensive Comparison"}]},{"@type":"WebSite","@id":"https:\/\/instrava.com\/#website","url":"https:\/\/instrava.com\/","name":"instrava.com","description":"","publisher":{"@id":"https:\/\/instrava.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrava.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/instrava.com\/#organization","name":"instrava.com","url":"https:\/\/instrava.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","width":288,"height":59,"caption":"instrava.com"},"image":{"@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6","name":"Instrava","sameAs":["https:\/\/instrava.com"],"url":"https:\/\/instrava.com\/es\/author\/matrinpolergmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/posts\/30560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/comments?post=30560"}],"version-history":[{"count":0,"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/posts\/30560\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/media\/30566"}],"wp:attachment":[{"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/media?parent=30560"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/categories?post=30560"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrava.com\/es\/wp-json\/wp\/v2\/tags?post=30560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}