{"id":30541,"date":"2026-01-06T11:37:03","date_gmt":"2026-01-06T11:37:03","guid":{"rendered":"https:\/\/instrava.com\/?p=30541"},"modified":"2026-01-06T11:59:25","modified_gmt":"2026-01-06T11:59:25","slug":"jauge-de-niveau-magnetique-vs-jauge-de-niveau-hydrostatique-technologie-et-guide-de-selection","status":"publish","type":"post","link":"https:\/\/instrava.com\/fr\/jauge-de-niveau-magnetique-vs-jauge-de-niveau-hydrostatique-technologie-et-guide-de-selection\/","title":{"rendered":"Indicateur de niveau magn\u00e9tique vs indicateur de niveau hydrostatique : Technologie et guide de s\u00e9lection"},"content":{"rendered":"<h2 data-start=\"217\" data-end=\"236\"><strong data-start=\"220\" data-end=\"236\">Introduction<\/strong><\/h2>\n<p data-start=\"238\" data-end=\"488\">Les jauges de niveau magn\u00e9tiques et les jauges de niveau hydrostatiques sont deux instruments largement utilis\u00e9s pour la surveillance du niveau des liquides dans l'industrie. Les deux technologies sont matures et fiables, mais elles servent des objectifs diff\u00e9rents et conviennent \u00e0 des conditions de processus diff\u00e9rentes.<\/p>\n<p data-start=\"490\" data-end=\"808\">Du point de vue d'un fabricant OEM, il est essentiel de comprendre les diff\u00e9rences entre un indicateur de niveau magn\u00e9tique et un indicateur de niveau hydrostatique pour choisir la bonne solution de mesure de niveau. Cet article compare les deux types en termes de principe de fonctionnement, de performances, d'installation et d'ad\u00e9quation \u00e0 l'application.<\/p>\n<hr data-start=\"810\" data-end=\"813\" \/>\n<h2 data-start=\"815\" data-end=\"839\"><strong data-start=\"818\" data-end=\"839\">Principe de fonctionnement<\/strong><\/h2>\n<h3 data-start=\"841\" data-end=\"869\"><strong data-start=\"845\" data-end=\"869\">Indicateur de niveau magn\u00e9tique<\/strong><\/h3>\n<p data-start=\"871\" data-end=\"1160\">A <strong><a href=\"https:\/\/instrava.com\/product\/magnetic-level-oil-gas-storage-tank\/\">jauge de niveau magn\u00e9tique<\/a><\/strong> est un instrument visuel \u00e0 contact. Il se compose d'un flotteur contenant un aimant permanent qui monte et descend \u00e0 l'int\u00e9rieur d'une chambre scell\u00e9e lorsque le niveau de liquide change. Des volets indicateurs externes ou un affichage magn\u00e9tique suivent la position du flotteur pour indiquer le niveau en temps r\u00e9el.<\/p>\n<p data-start=\"1162\" data-end=\"1283\">Les indicateurs de niveau magn\u00e9tiques fournissent une indication directe et intuitive du niveau sans n\u00e9cessiter d'alimentation \u00e9lectrique ou de signaux \u00e9lectroniques.<\/p>\n<hr data-start=\"1285\" data-end=\"1288\" \/>\n<h3 data-start=\"1290\" data-end=\"1321\"><strong data-start=\"1294\" data-end=\"1321\">Jauge de niveau hydrostatique<\/strong><\/h3>\n<p data-start=\"1323\" data-end=\"1538\"><a href=\"https:\/\/instrava.com\/product\/hydrostatic-pressure-transmitter\/\"><strong>Indicateurs de niveau hydrostatique<\/strong><\/a> mesurer le niveau de liquide en fonction de la pression. L'appareil d\u00e9tecte la pression hydrostatique g\u00e9n\u00e9r\u00e9e par la hauteur de la colonne de liquide et la convertit en un signal de sortie standard tel que 4-20 mA.<\/p>\n<p data-start=\"1540\" data-end=\"1668\">Ce type de jauge de niveau est un instrument de mesure \u00e9lectronique et n\u00e9cessite une densit\u00e9 de liquide stable pour garantir des relev\u00e9s pr\u00e9cis.<\/p>\n<hr data-start=\"1670\" data-end=\"1673\" \/>\n<h2 data-start=\"1675\" data-end=\"1704\"><strong data-start=\"1678\" data-end=\"1704\">Comparaison des performances<\/strong><\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1706\" data-end=\"2285\">\n<thead data-start=\"1706\" data-end=\"1763\">\n<tr data-start=\"1706\" data-end=\"1763\">\n<th data-start=\"1706\" data-end=\"1713\" data-col-size=\"sm\">Objet<\/th>\n<th data-start=\"1713\" data-end=\"1736\" data-col-size=\"sm\">Indicateur de niveau magn\u00e9tique<\/th>\n<th data-start=\"1736\" data-end=\"1763\" data-col-size=\"sm\">Jauge de niveau hydrostatique<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1820\" data-end=\"2285\">\n<tr data-start=\"1820\" data-end=\"1897\">\n<td data-start=\"1820\" data-end=\"1841\" data-col-size=\"sm\">M\u00e9thode de mesure<\/td>\n<td data-col-size=\"sm\" data-start=\"1841\" data-end=\"1868\">Indication visuelle directe<\/td>\n<td data-col-size=\"sm\" data-start=\"1868\" data-end=\"1897\">\u00c9lectronique bas\u00e9e sur la pression<\/td>\n<\/tr>\n<tr data-start=\"1898\" data-end=\"1940\">\n<td data-start=\"1898\" data-end=\"1913\" data-col-size=\"sm\">Alimentation \u00e9lectrique<\/td>\n<td data-col-size=\"sm\" data-start=\"1913\" data-end=\"1928\">Pas n\u00e9cessaire<\/td>\n<td data-col-size=\"sm\" data-start=\"1928\" data-end=\"1940\">Exig\u00e9e<\/td>\n<\/tr>\n<tr data-start=\"1941\" data-end=\"2008\">\n<td data-start=\"1941\" data-end=\"1952\" data-col-size=\"sm\">Pr\u00e9cision<\/td>\n<td data-col-size=\"sm\" data-start=\"1952\" data-end=\"1980\">Haut pour l'indication locale<\/td>\n<td data-col-size=\"sm\" data-start=\"1980\" data-end=\"2008\">Densit\u00e9 \u00e9lev\u00e9e et stable<\/td>\n<\/tr>\n<tr data-start=\"2009\" data-end=\"2085\">\n<td data-start=\"2009\" data-end=\"2025\" data-col-size=\"sm\">Signal de sortie<\/td>\n<td data-col-size=\"sm\" data-start=\"2025\" data-end=\"2055\">Sortie de l'\u00e9metteur en option<\/td>\n<td data-col-size=\"sm\" data-start=\"2055\" data-end=\"2085\">Sortie \u00e9lectrique standard<\/td>\n<\/tr>\n<tr data-start=\"2086\" data-end=\"2113\">\n<td data-start=\"2086\" data-end=\"2100\" data-col-size=\"sm\">Maintenance<\/td>\n<td data-col-size=\"sm\" data-start=\"2100\" data-end=\"2106\">Faible<\/td>\n<td data-col-size=\"sm\" data-start=\"2106\" data-end=\"2113\">Faible<\/td>\n<\/tr>\n<tr data-start=\"2114\" data-end=\"2146\">\n<td data-start=\"2114\" data-end=\"2134\" data-col-size=\"sm\">Influence de la densit\u00e9<\/td>\n<td data-col-size=\"sm\" data-start=\"2134\" data-end=\"2139\">Non<\/td>\n<td data-col-size=\"sm\" data-start=\"2139\" data-end=\"2146\">Oui<\/td>\n<\/tr>\n<tr data-start=\"2147\" data-end=\"2209\">\n<td data-start=\"2147\" data-end=\"2171\" data-col-size=\"sm\">Tol\u00e9rance de temp\u00e9rature<\/td>\n<td data-col-size=\"sm\" data-start=\"2171\" data-end=\"2178\">Bon<\/td>\n<td data-col-size=\"sm\" data-start=\"2178\" data-end=\"2209\">Limit\u00e9 \u00e0 haute temp\u00e9rature<\/td>\n<\/tr>\n<tr data-start=\"2210\" data-end=\"2251\">\n<td data-start=\"2210\" data-end=\"2233\" data-col-size=\"sm\">Ad\u00e9quation de la pression<\/td>\n<td data-col-size=\"sm\" data-start=\"2233\" data-end=\"2240\">Bon<\/td>\n<td data-col-size=\"sm\" data-start=\"2240\" data-end=\"2251\">Limit\u00e9e<\/td>\n<\/tr>\n<tr data-start=\"2252\" data-end=\"2285\">\n<td data-start=\"2252\" data-end=\"2267\" data-col-size=\"sm\">Risque de d\u00e9faillance<\/td>\n<td data-col-size=\"sm\" data-start=\"2267\" data-end=\"2278\">Tr\u00e8s faible<\/td>\n<td data-col-size=\"sm\" data-start=\"2278\" data-end=\"2285\">Faible<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<hr data-start=\"2287\" data-end=\"2290\" \/>\n<h2 data-start=\"2292\" data-end=\"2322\"><strong data-start=\"2295\" data-end=\"2322\">Comparaison des installations<\/strong><\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2324\" data-end=\"2815\">\n<thead data-start=\"2324\" data-end=\"2396\">\n<tr data-start=\"2324\" data-end=\"2396\">\n<th data-start=\"2324\" data-end=\"2346\" data-col-size=\"sm\">Facteur d'installation<\/th>\n<th data-start=\"2346\" data-end=\"2369\" data-col-size=\"sm\">Indicateur de niveau magn\u00e9tique<\/th>\n<th data-start=\"2369\" data-end=\"2396\" data-col-size=\"sm\">Jauge de niveau hydrostatique<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2467\" data-end=\"2815\">\n<tr data-start=\"2467\" data-end=\"2533\">\n<td data-start=\"2467\" data-end=\"2487\" data-col-size=\"sm\">Position de montage<\/td>\n<td data-col-size=\"sm\" data-start=\"2487\" data-end=\"2510\">Montage lat\u00e9ral sur le r\u00e9servoir<\/td>\n<td data-col-size=\"sm\" data-start=\"2510\" data-end=\"2533\">Fond ou immerg\u00e9<\/td>\n<\/tr>\n<tr data-start=\"2534\" data-end=\"2605\">\n<td data-start=\"2534\" data-end=\"2555\" data-col-size=\"sm\">Connexion au processus<\/td>\n<td data-col-size=\"sm\" data-start=\"2555\" data-end=\"2583\">N\u00e9cessite une chambre externe<\/td>\n<td data-col-size=\"sm\" data-start=\"2583\" data-end=\"2605\">Filet\u00e9e ou \u00e0 bride<\/td>\n<\/tr>\n<tr data-start=\"2606\" data-end=\"2677\">\n<td data-start=\"2606\" data-end=\"2623\" data-col-size=\"sm\">Contact moyen<\/td>\n<td data-col-size=\"sm\" data-start=\"2623\" data-end=\"2649\">Flotteur en contact direct<\/td>\n<td data-col-size=\"sm\" data-start=\"2649\" data-end=\"2677\">Capteur en contact direct<\/td>\n<\/tr>\n<tr data-start=\"2678\" data-end=\"2710\">\n<td data-start=\"2678\" data-end=\"2687\" data-col-size=\"sm\">C\u00e2blage<\/td>\n<td data-col-size=\"sm\" data-start=\"2687\" data-end=\"2700\">Pas n\u00e9cessaire<\/td>\n<td data-col-size=\"sm\" data-start=\"2700\" data-end=\"2710\">Besoin d'aide<\/td>\n<\/tr>\n<tr data-start=\"2711\" data-end=\"2750\">\n<td data-start=\"2711\" data-end=\"2735\" data-col-size=\"sm\">Influence de l'obstruction<\/td>\n<td data-col-size=\"sm\" data-start=\"2735\" data-end=\"2742\">Aucun<\/td>\n<td data-col-size=\"sm\" data-start=\"2742\" data-end=\"2750\">Aucun<\/td>\n<\/tr>\n<tr data-start=\"2751\" data-end=\"2815\">\n<td data-start=\"2751\" data-end=\"2772\" data-col-size=\"sm\">Acc\u00e8s \u00e0 la maintenance<\/td>\n<td data-col-size=\"sm\" data-start=\"2772\" data-end=\"2791\">Acc\u00e8s lat\u00e9ral facile<\/td>\n<td data-col-size=\"sm\" data-start=\"2791\" data-end=\"2815\">Acc\u00e8s par le bas n\u00e9cessaire<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<hr data-start=\"2817\" data-end=\"2820\" \/>\n<h2 data-start=\"2822\" data-end=\"2849\"><strong data-start=\"2825\" data-end=\"2849\">Applications typiques<\/strong><\/h2>\n<h3 data-start=\"2851\" data-end=\"2892\"><strong data-start=\"2855\" data-end=\"2892\">Applications de la jauge de niveau magn\u00e9tique<\/strong><\/h3>\n<p data-start=\"2894\" data-end=\"2930\">Les jauges de niveau magn\u00e9tiques sont id\u00e9ales pour :<\/p>\n<ul data-start=\"2931\" data-end=\"3121\">\n<li data-start=\"2931\" data-end=\"2959\">\n<p data-start=\"2933\" data-end=\"2959\">Chaudi\u00e8res \u00e0 haute temp\u00e9rature<\/p>\n<\/li>\n<li data-start=\"2960\" data-end=\"2983\">\n<p data-start=\"2962\" data-end=\"2983\">R\u00e9cipients sous pression<\/p>\n<\/li>\n<li data-start=\"2984\" data-end=\"3012\">\n<p data-start=\"2986\" data-end=\"3012\">R\u00e9servoirs de produits chimiques corrosifs<\/p>\n<\/li>\n<li data-start=\"3013\" data-end=\"3064\">\n<p data-start=\"3015\" data-end=\"3064\">Situations n\u00e9cessitant un affichage visuel local du niveau<\/p>\n<\/li>\n<li data-start=\"3065\" data-end=\"3121\">\n<p data-start=\"3067\" data-end=\"3121\">Processus critiques en mati\u00e8re de s\u00e9curit\u00e9 sans disponibilit\u00e9 de l'\u00e9nergie<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3123\" data-end=\"3254\">Ils sont couramment utilis\u00e9s dans les usines p\u00e9trochimiques, les r\u00e9servoirs de stockage et les cuves de traitement o\u00f9 les op\u00e9rateurs ont besoin d'une surveillance intuitive du niveau.<\/p>\n<hr data-start=\"3256\" data-end=\"3259\" \/>\n<h3 data-start=\"3261\" data-end=\"3305\"><strong data-start=\"3265\" data-end=\"3305\">Applications des indicateurs de niveau hydrostatiques<\/strong><\/h3>\n<p data-start=\"3307\" data-end=\"3349\">Les indicateurs de niveau hydrostatiques conviennent pour :<\/p>\n<ul data-start=\"3350\" data-end=\"3499\">\n<li data-start=\"3350\" data-end=\"3371\">\n<p data-start=\"3352\" data-end=\"3371\">R\u00e9servoirs atmosph\u00e9riques<\/p>\n<\/li>\n<li data-start=\"3372\" data-end=\"3399\">\n<p data-start=\"3374\" data-end=\"3399\">Syst\u00e8mes de traitement des eaux<\/p>\n<\/li>\n<li data-start=\"3400\" data-end=\"3426\">\n<p data-start=\"3402\" data-end=\"3426\">R\u00e9servoirs souterrains<\/p>\n<\/li>\n<li data-start=\"3427\" data-end=\"3457\">\n<p data-start=\"3429\" data-end=\"3457\">R\u00e9servoirs de stockage de carburant et d'huile<\/p>\n<\/li>\n<li data-start=\"3458\" data-end=\"3499\">\n<p data-start=\"3460\" data-end=\"3499\">Surveillance \u00e0 distance via des syst\u00e8mes de contr\u00f4le<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3501\" data-end=\"3581\">Cette technologie est souvent choisie lorsqu'une sortie \u00e9lectronique continue est n\u00e9cessaire.<\/p>\n<hr data-start=\"3583\" data-end=\"3586\" \/>\n<h2 data-start=\"3588\" data-end=\"3642\"><strong data-start=\"3591\" data-end=\"3642\">Guide de s\u00e9lection du point de vue du fabricant<\/strong><\/h2>\n<p data-start=\"3644\" data-end=\"3723\">Lorsqu'ils choisissent entre ces deux indicateurs de niveau, les fabricants prennent g\u00e9n\u00e9ralement en compte les \u00e9l\u00e9ments suivants :<\/p>\n<ul data-start=\"3725\" data-end=\"3912\">\n<li data-start=\"3725\" data-end=\"3772\">\n<p data-start=\"3727\" data-end=\"3772\">Si une indication visuelle locale est n\u00e9cessaire<\/p>\n<\/li>\n<li data-start=\"3773\" data-end=\"3809\">\n<p data-start=\"3775\" data-end=\"3809\">Temp\u00e9rature et pression du processus<\/p>\n<\/li>\n<li data-start=\"3810\" data-end=\"3849\">\n<p data-start=\"3812\" data-end=\"3849\">N\u00e9cessit\u00e9 d'une transmission \u00e0 distance des signaux<\/p>\n<\/li>\n<li data-start=\"3850\" data-end=\"3878\">\n<p data-start=\"3852\" data-end=\"3878\">Stabilit\u00e9 de la densit\u00e9 du liquide<\/p>\n<\/li>\n<li data-start=\"3879\" data-end=\"3912\">\n<p data-start=\"3881\" data-end=\"3912\">Espace d'installation et budget<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3914\" data-end=\"4080\">Les jauges de niveau magn\u00e9tiques sont pr\u00e9f\u00e9r\u00e9es pour les environnements difficiles et l'indication directe, tandis que les jauges de niveau hydrostatiques sont choisies pour les projets \u00e9conomiques de surveillance \u00e0 distance.<\/p>\n<hr data-start=\"4082\" data-end=\"4085\" \/>\n<h2 data-start=\"4087\" data-end=\"4104\"><strong data-start=\"4090\" data-end=\"4104\">Conclusion<\/strong><\/h2>\n<p data-start=\"4106\" data-end=\"4416\">Les jauges de niveau magn\u00e9tiques et les jauges de niveau hydrostatiques pr\u00e9sentent chacune des avantages uniques dans la mesure du niveau industriel. La jauge de niveau magn\u00e9tique offre une indication visuelle simple, s\u00fbre et tr\u00e8s fiable. La jauge de niveau hydrostatique fournit une sortie \u00e9lectronique pr\u00e9cise et rentable pour les applications conventionnelles.<\/p>\n<p data-start=\"4418\" data-end=\"4601\">En comprenant leurs diff\u00e9rences et en consultant des fabricants exp\u00e9riment\u00e9s de jauges de niveau OEM, les utilisateurs peuvent choisir la solution de mesure de niveau la plus adapt\u00e9e \u00e0 leurs r\u00e9servoirs et cuves.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Magnetic level gauges and hydrostatic level gauges are two widely used instruments for industrial liquid level monitoring. Both technologies are mature and reliable, but they serve different purposes and are suitable for different process conditions. From an OEM manufacturer\u2019s perspective, understanding the differences between a magnetic level gauge and a hydrostatic level gauge is&#8230;<\/p>","protected":false},"author":1,"featured_media":30542,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[295],"tags":[310,324,326,306,331,325,309],"class_list":["post-30541","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-level-gauge","tag-4-20ma-signal","tag-ce","tag-chemical-industry","tag-hydrostatic-pressure","tag-intrinsically-safe","tag-rohs","tag-working-principle"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava<\/title>\n<meta name=\"description\" content=\"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrava.com\/fr\/jauge-de-niveau-magnetique-vs-jauge-de-niveau-hydrostatique-technologie-et-guide-de-selection\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava\" \/>\n<meta property=\"og:description\" content=\"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrava.com\/fr\/jauge-de-niveau-magnetique-vs-jauge-de-niveau-hydrostatique-technologie-et-guide-de-selection\/\" \/>\n<meta property=\"og:site_name\" content=\"Instrava\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-06T11:37:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-06T11:59:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Instrava\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Instrava\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\"},\"author\":{\"name\":\"Instrava\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\"},\"headline\":\"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide\",\"datePublished\":\"2026-01-06T11:37:03+00:00\",\"dateModified\":\"2026-01-06T11:59:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\"},\"wordCount\":542,\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"keywords\":[\"4\u201320mA Signal\",\"CE\",\"Chemical Industry\",\"Hydrostatic Pressure\",\"Intrinsically Safe\",\"RoHS\",\"Working Principle\"],\"articleSection\":[\"Level Gauge\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\",\"name\":\"Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"datePublished\":\"2026-01-06T11:37:03+00:00\",\"dateModified\":\"2026-01-06T11:59:25+00:00\",\"description\":\"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"width\":1200,\"height\":650,\"caption\":\"Magnetic level gauge vs hydrostatic level gauge comparison image, showing a magnetic level gauge on the left and a hydrostatic level transmitter on the right, highlighting differences in structure and level measurement methods.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrava.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Level Gauge\",\"item\":\"https:\\\/\\\/instrava.com\\\/category\\\/level-gauge\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"name\":\"instrava.com\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrava.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\",\"name\":\"instrava.com\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"width\":288,\"height\":59,\"caption\":\"instrava.com\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\",\"name\":\"Instrava\",\"sameAs\":[\"https:\\\/\\\/instrava.com\"],\"url\":\"https:\\\/\\\/instrava.com\\\/fr\\\/author\\\/matrinpolergmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Indicateur de niveau magn\u00e9tique vs indicateur de niveau hydrostatique - Instrava","description":"Comparez les jauges de niveau magn\u00e9tiques et les jauges de niveau hydrostatiques, et d\u00e9couvrez comment les fabricants OEM choisissent la bonne jauge de niveau pour les r\u00e9servoirs industriels.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrava.com\/fr\/jauge-de-niveau-magnetique-vs-jauge-de-niveau-hydrostatique-technologie-et-guide-de-selection\/","og_locale":"fr_FR","og_type":"article","og_title":"Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava","og_description":"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.","og_url":"https:\/\/instrava.com\/fr\/jauge-de-niveau-magnetique-vs-jauge-de-niveau-hydrostatique-technologie-et-guide-de-selection\/","og_site_name":"Instrava","article_published_time":"2026-01-06T11:37:03+00:00","article_modified_time":"2026-01-06T11:59:25+00:00","og_image":[{"width":1200,"height":650,"url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","type":"image\/webp"}],"author":"Instrava","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Instrava","Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#article","isPartOf":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/"},"author":{"name":"Instrava","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6"},"headline":"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide","datePublished":"2026-01-06T11:37:03+00:00","dateModified":"2026-01-06T11:59:25+00:00","mainEntityOfPage":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/"},"wordCount":542,"publisher":{"@id":"https:\/\/instrava.com\/#organization"},"image":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","keywords":["4\u201320mA Signal","CE","Chemical Industry","Hydrostatic Pressure","Intrinsically Safe","RoHS","Working Principle"],"articleSection":["Level Gauge"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/","url":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/","name":"Indicateur de niveau magn\u00e9tique vs indicateur de niveau hydrostatique - Instrava","isPartOf":{"@id":"https:\/\/instrava.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage"},"image":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","datePublished":"2026-01-06T11:37:03+00:00","dateModified":"2026-01-06T11:59:25+00:00","description":"Comparez les jauges de niveau magn\u00e9tiques et les jauges de niveau hydrostatiques, et d\u00e9couvrez comment les fabricants OEM choisissent la bonne jauge de niveau pour les r\u00e9servoirs industriels.","breadcrumb":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage","url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","width":1200,"height":650,"caption":"Magnetic level gauge vs hydrostatic level gauge comparison image, showing a magnetic level gauge on the left and a hydrostatic level transmitter on the right, highlighting differences in structure and level measurement methods."},{"@type":"BreadcrumbList","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrava.com\/"},{"@type":"ListItem","position":2,"name":"Level Gauge","item":"https:\/\/instrava.com\/category\/level-gauge\/"},{"@type":"ListItem","position":3,"name":"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/instrava.com\/#website","url":"https:\/\/instrava.com\/","name":"instrava.com","description":"","publisher":{"@id":"https:\/\/instrava.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrava.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/instrava.com\/#organization","name":"instrava.com","url":"https:\/\/instrava.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","width":288,"height":59,"caption":"instrava.com"},"image":{"@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6","name":"Instrava","sameAs":["https:\/\/instrava.com"],"url":"https:\/\/instrava.com\/fr\/author\/matrinpolergmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/posts\/30541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/comments?post=30541"}],"version-history":[{"count":0,"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/posts\/30541\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/media\/30542"}],"wp:attachment":[{"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/media?parent=30541"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/categories?post=30541"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrava.com\/fr\/wp-json\/wp\/v2\/tags?post=30541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}