{"id":30541,"date":"2026-01-06T11:37:03","date_gmt":"2026-01-06T11:37:03","guid":{"rendered":"https:\/\/instrava.com\/?p=30541"},"modified":"2026-01-06T11:59:25","modified_gmt":"2026-01-06T11:59:25","slug":"magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide","status":"publish","type":"post","link":"https:\/\/instrava.com\/id\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/","title":{"rendered":"Pengukur Level Magnetik vs Pengukur Level Hidrostatik: Panduan Teknologi dan Pemilihan"},"content":{"rendered":"<h2 data-start=\"217\" data-end=\"236\"><strong data-start=\"220\" data-end=\"236\">Pendahuluan<\/strong><\/h2>\n<p data-start=\"238\" data-end=\"488\">Pengukur level magnetik dan pengukur level hidrostatis adalah dua instrumen yang banyak digunakan untuk pemantauan level cairan industri. Kedua teknologi ini sudah matang dan dapat diandalkan, tetapi keduanya memiliki tujuan yang berbeda dan cocok untuk kondisi proses yang berbeda.<\/p>\n<p data-start=\"490\" data-end=\"808\">Dari sudut pandang produsen OEM, memahami perbedaan antara pengukur level magnetik dan pengukur level hidrostatik sangat penting untuk memilih solusi pengukuran level yang tepat. Artikel ini membandingkan kedua jenis tersebut dalam hal prinsip kerja, kinerja, pemasangan, dan kesesuaian aplikasi.<\/p>\n<hr data-start=\"810\" data-end=\"813\" \/>\n<h2 data-start=\"815\" data-end=\"839\"><strong data-start=\"818\" data-end=\"839\">Prinsip Kerja<\/strong><\/h2>\n<h3 data-start=\"841\" data-end=\"869\"><strong data-start=\"845\" data-end=\"869\">Pengukur Level Magnetik<\/strong><\/h3>\n<p data-start=\"871\" data-end=\"1160\">A <strong><a href=\"https:\/\/instrava.com\/product\/magnetic-level-oil-gas-storage-tank\/\">pengukur level magnetik<\/a><\/strong> adalah instrumen tipe kontak visual. Alat ini terdiri dari pelampung yang berisi magnet permanen yang bergerak naik dan turun di dalam ruang tertutup saat level cairan berubah. Penutup indikator eksternal atau layar magnetik melacak posisi pelampung untuk menunjukkan level waktu nyata.<\/p>\n<p data-start=\"1162\" data-end=\"1283\">Pengukur level magnetik memberikan indikasi level secara langsung dan intuitif tanpa memerlukan catu daya atau sinyal elektronik.<\/p>\n<hr data-start=\"1285\" data-end=\"1288\" \/>\n<h3 data-start=\"1290\" data-end=\"1321\"><strong data-start=\"1294\" data-end=\"1321\">Pengukur Tingkat Hidrostatik<\/strong><\/h3>\n<p data-start=\"1323\" data-end=\"1538\"><a href=\"https:\/\/instrava.com\/product\/hydrostatic-pressure-transmitter\/\"><strong>Pengukur level hidrostatis<\/strong><\/a> mengukur level cairan berdasarkan tekanan. Perangkat mendeteksi tekanan hidrostatik yang dihasilkan oleh ketinggian kolom cairan dan mengubahnya menjadi sinyal output standar seperti 4-20 mA.<\/p>\n<p data-start=\"1540\" data-end=\"1668\">Pengukur level jenis ini adalah instrumen pengukuran elektronik dan memerlukan kepadatan cairan yang stabil untuk memastikan pembacaan yang akurat.<\/p>\n<hr data-start=\"1670\" data-end=\"1673\" \/>\n<h2 data-start=\"1675\" data-end=\"1704\"><strong data-start=\"1678\" data-end=\"1704\">Perbandingan Kinerja<\/strong><\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1706\" data-end=\"2285\">\n<thead data-start=\"1706\" data-end=\"1763\">\n<tr data-start=\"1706\" data-end=\"1763\">\n<th data-start=\"1706\" data-end=\"1713\" data-col-size=\"sm\">Item<\/th>\n<th data-start=\"1713\" data-end=\"1736\" data-col-size=\"sm\">Pengukur Level Magnetik<\/th>\n<th data-start=\"1736\" data-end=\"1763\" data-col-size=\"sm\">Pengukur Tingkat Hidrostatik<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1820\" data-end=\"2285\">\n<tr data-start=\"1820\" data-end=\"1897\">\n<td data-start=\"1820\" data-end=\"1841\" data-col-size=\"sm\">Metode Pengukuran<\/td>\n<td data-col-size=\"sm\" data-start=\"1841\" data-end=\"1868\">Indikasi visual langsung<\/td>\n<td data-col-size=\"sm\" data-start=\"1868\" data-end=\"1897\">Elektronik berbasis tekanan<\/td>\n<\/tr>\n<tr data-start=\"1898\" data-end=\"1940\">\n<td data-start=\"1898\" data-end=\"1913\" data-col-size=\"sm\">Catu Daya<\/td>\n<td data-col-size=\"sm\" data-start=\"1913\" data-end=\"1928\">Tidak diperlukan<\/td>\n<td data-col-size=\"sm\" data-start=\"1928\" data-end=\"1940\">Diperlukan<\/td>\n<\/tr>\n<tr data-start=\"1941\" data-end=\"2008\">\n<td data-start=\"1941\" data-end=\"1952\" data-col-size=\"sm\">Akurasi<\/td>\n<td data-col-size=\"sm\" data-start=\"1952\" data-end=\"1980\">Tinggi untuk indikasi lokal<\/td>\n<td data-col-size=\"sm\" data-start=\"1980\" data-end=\"2008\">Tinggi dengan kepadatan yang stabil<\/td>\n<\/tr>\n<tr data-start=\"2009\" data-end=\"2085\">\n<td data-start=\"2009\" data-end=\"2025\" data-col-size=\"sm\">Sinyal Keluaran<\/td>\n<td data-col-size=\"sm\" data-start=\"2025\" data-end=\"2055\">Output pemancar opsional<\/td>\n<td data-col-size=\"sm\" data-start=\"2055\" data-end=\"2085\">Output listrik standar<\/td>\n<\/tr>\n<tr data-start=\"2086\" data-end=\"2113\">\n<td data-start=\"2086\" data-end=\"2100\" data-col-size=\"sm\">Pemeliharaan<\/td>\n<td data-col-size=\"sm\" data-start=\"2100\" data-end=\"2106\">Rendah<\/td>\n<td data-col-size=\"sm\" data-start=\"2106\" data-end=\"2113\">Rendah<\/td>\n<\/tr>\n<tr data-start=\"2114\" data-end=\"2146\">\n<td data-start=\"2114\" data-end=\"2134\" data-col-size=\"sm\">Pengaruh Kepadatan<\/td>\n<td data-col-size=\"sm\" data-start=\"2134\" data-end=\"2139\">Tidak.<\/td>\n<td data-col-size=\"sm\" data-start=\"2139\" data-end=\"2146\">Ya.<\/td>\n<\/tr>\n<tr data-start=\"2147\" data-end=\"2209\">\n<td data-start=\"2147\" data-end=\"2171\" data-col-size=\"sm\">Toleransi Suhu<\/td>\n<td data-col-size=\"sm\" data-start=\"2171\" data-end=\"2178\">Bagus.<\/td>\n<td data-col-size=\"sm\" data-start=\"2178\" data-end=\"2209\">Terbatas pada suhu tinggi<\/td>\n<\/tr>\n<tr data-start=\"2210\" data-end=\"2251\">\n<td data-start=\"2210\" data-end=\"2233\" data-col-size=\"sm\">Kesesuaian Tekanan<\/td>\n<td data-col-size=\"sm\" data-start=\"2233\" data-end=\"2240\">Bagus.<\/td>\n<td data-col-size=\"sm\" data-start=\"2240\" data-end=\"2251\">Terbatas<\/td>\n<\/tr>\n<tr data-start=\"2252\" data-end=\"2285\">\n<td data-start=\"2252\" data-end=\"2267\" data-col-size=\"sm\">Risiko Kegagalan<\/td>\n<td data-col-size=\"sm\" data-start=\"2267\" data-end=\"2278\">Sangat rendah<\/td>\n<td data-col-size=\"sm\" data-start=\"2278\" data-end=\"2285\">Rendah<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<hr data-start=\"2287\" data-end=\"2290\" \/>\n<h2 data-start=\"2292\" data-end=\"2322\"><strong data-start=\"2295\" data-end=\"2322\">Perbandingan Instalasi<\/strong><\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2324\" data-end=\"2815\">\n<thead data-start=\"2324\" data-end=\"2396\">\n<tr data-start=\"2324\" data-end=\"2396\">\n<th data-start=\"2324\" data-end=\"2346\" data-col-size=\"sm\">Faktor Instalasi<\/th>\n<th data-start=\"2346\" data-end=\"2369\" data-col-size=\"sm\">Pengukur Level Magnetik<\/th>\n<th data-start=\"2369\" data-end=\"2396\" data-col-size=\"sm\">Pengukur Tingkat Hidrostatik<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2467\" data-end=\"2815\">\n<tr data-start=\"2467\" data-end=\"2533\">\n<td data-start=\"2467\" data-end=\"2487\" data-col-size=\"sm\">Posisi Pemasangan<\/td>\n<td data-col-size=\"sm\" data-start=\"2487\" data-end=\"2510\">Sisi dipasang pada tangki<\/td>\n<td data-col-size=\"sm\" data-start=\"2510\" data-end=\"2533\">Bawah atau terendam<\/td>\n<\/tr>\n<tr data-start=\"2534\" data-end=\"2605\">\n<td data-start=\"2534\" data-end=\"2555\" data-col-size=\"sm\">Koneksi Proses<\/td>\n<td data-col-size=\"sm\" data-start=\"2555\" data-end=\"2583\">Membutuhkan ruang eksternal<\/td>\n<td data-col-size=\"sm\" data-start=\"2583\" data-end=\"2605\">Berulir atau flensa<\/td>\n<\/tr>\n<tr data-start=\"2606\" data-end=\"2677\">\n<td data-start=\"2606\" data-end=\"2623\" data-col-size=\"sm\">Kontak Sedang<\/td>\n<td data-col-size=\"sm\" data-start=\"2623\" data-end=\"2649\">Mengapung dalam kontak langsung<\/td>\n<td data-col-size=\"sm\" data-start=\"2649\" data-end=\"2677\">Sensor dalam kontak langsung<\/td>\n<\/tr>\n<tr data-start=\"2678\" data-end=\"2710\">\n<td data-start=\"2678\" data-end=\"2687\" data-col-size=\"sm\">Pengkabelan<\/td>\n<td data-col-size=\"sm\" data-start=\"2687\" data-end=\"2700\">Tidak diperlukan<\/td>\n<td data-col-size=\"sm\" data-start=\"2700\" data-end=\"2710\">Dibutuhkan<\/td>\n<\/tr>\n<tr data-start=\"2711\" data-end=\"2750\">\n<td data-start=\"2711\" data-end=\"2735\" data-col-size=\"sm\">Pengaruh Obstruksi<\/td>\n<td data-col-size=\"sm\" data-start=\"2735\" data-end=\"2742\">Tidak ada<\/td>\n<td data-col-size=\"sm\" data-start=\"2742\" data-end=\"2750\">Tidak ada<\/td>\n<\/tr>\n<tr data-start=\"2751\" data-end=\"2815\">\n<td data-start=\"2751\" data-end=\"2772\" data-col-size=\"sm\">Akses Pemeliharaan<\/td>\n<td data-col-size=\"sm\" data-start=\"2772\" data-end=\"2791\">Akses samping yang mudah<\/td>\n<td data-col-size=\"sm\" data-start=\"2791\" data-end=\"2815\">Akses bawah diperlukan<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<hr data-start=\"2817\" data-end=\"2820\" \/>\n<h2 data-start=\"2822\" data-end=\"2849\"><strong data-start=\"2825\" data-end=\"2849\">Aplikasi Khas<\/strong><\/h2>\n<h3 data-start=\"2851\" data-end=\"2892\"><strong data-start=\"2855\" data-end=\"2892\">Aplikasi Pengukur Level Magnetik<\/strong><\/h3>\n<p data-start=\"2894\" data-end=\"2930\">Pengukur level magnetik sangat ideal untuk:<\/p>\n<ul data-start=\"2931\" data-end=\"3121\">\n<li data-start=\"2931\" data-end=\"2959\">\n<p data-start=\"2933\" data-end=\"2959\">Ketel suhu tinggi<\/p>\n<\/li>\n<li data-start=\"2960\" data-end=\"2983\">\n<p data-start=\"2962\" data-end=\"2983\">Kapal bertekanan<\/p>\n<\/li>\n<li data-start=\"2984\" data-end=\"3012\">\n<p data-start=\"2986\" data-end=\"3012\">Tangki bahan kimia korosif<\/p>\n<\/li>\n<li data-start=\"3013\" data-end=\"3064\">\n<p data-start=\"3015\" data-end=\"3064\">Situasi yang membutuhkan tampilan tingkat visual lokal<\/p>\n<\/li>\n<li data-start=\"3065\" data-end=\"3121\">\n<p data-start=\"3067\" data-end=\"3121\">Proses yang sangat penting bagi keselamatan tanpa ketersediaan daya<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3123\" data-end=\"3254\">Mereka biasanya digunakan di pabrik petrokimia, tangki penyimpanan, dan kapal proses di mana operator membutuhkan pemantauan level yang intuitif.<\/p>\n<hr data-start=\"3256\" data-end=\"3259\" \/>\n<h3 data-start=\"3261\" data-end=\"3305\"><strong data-start=\"3265\" data-end=\"3305\">Aplikasi Pengukur Level Hidrostatik<\/strong><\/h3>\n<p data-start=\"3307\" data-end=\"3349\">Pengukur level hidrostatis cocok untuk:<\/p>\n<ul data-start=\"3350\" data-end=\"3499\">\n<li data-start=\"3350\" data-end=\"3371\">\n<p data-start=\"3352\" data-end=\"3371\">Tangki atmosfer<\/p>\n<\/li>\n<li data-start=\"3372\" data-end=\"3399\">\n<p data-start=\"3374\" data-end=\"3399\">Sistem pengolahan air<\/p>\n<\/li>\n<li data-start=\"3400\" data-end=\"3426\">\n<p data-start=\"3402\" data-end=\"3426\">Waduk bawah tanah<\/p>\n<\/li>\n<li data-start=\"3427\" data-end=\"3457\">\n<p data-start=\"3429\" data-end=\"3457\">Tangki penyimpanan bahan bakar dan minyak<\/p>\n<\/li>\n<li data-start=\"3458\" data-end=\"3499\">\n<p data-start=\"3460\" data-end=\"3499\">Pemantauan jarak jauh melalui sistem kontrol<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3501\" data-end=\"3581\">Teknologi ini sering dipilih apabila diperlukan output elektronik yang terus menerus.<\/p>\n<hr data-start=\"3583\" data-end=\"3586\" \/>\n<h2 data-start=\"3588\" data-end=\"3642\"><strong data-start=\"3591\" data-end=\"3642\">Panduan Pemilihan dari Perspektif Produsen<\/strong><\/h2>\n<p data-start=\"3644\" data-end=\"3723\">Ketika memilih di antara kedua pengukur level ini, produsen biasanya mempertimbangkan:<\/p>\n<ul data-start=\"3725\" data-end=\"3912\">\n<li data-start=\"3725\" data-end=\"3772\">\n<p data-start=\"3727\" data-end=\"3772\">Apakah indikasi lokal visual diperlukan<\/p>\n<\/li>\n<li data-start=\"3773\" data-end=\"3809\">\n<p data-start=\"3775\" data-end=\"3809\">Suhu dan tekanan proses<\/p>\n<\/li>\n<li data-start=\"3810\" data-end=\"3849\">\n<p data-start=\"3812\" data-end=\"3849\">Kebutuhan untuk transmisi sinyal jarak jauh<\/p>\n<\/li>\n<li data-start=\"3850\" data-end=\"3878\">\n<p data-start=\"3852\" data-end=\"3878\">Stabilitas kepadatan cairan<\/p>\n<\/li>\n<li data-start=\"3879\" data-end=\"3912\">\n<p data-start=\"3881\" data-end=\"3912\">Ruang instalasi dan anggaran<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3914\" data-end=\"4080\">Pengukur level magnetik lebih disukai untuk lingkungan yang keras dan indikasi langsung, sedangkan pengukur level hidrostatis dipilih untuk proyek pemantauan jarak jauh yang ekonomis.<\/p>\n<hr data-start=\"4082\" data-end=\"4085\" \/>\n<h2 data-start=\"4087\" data-end=\"4104\"><strong data-start=\"4090\" data-end=\"4104\">Kesimpulan<\/strong><\/h2>\n<p data-start=\"4106\" data-end=\"4416\">Pengukur level magnetik dan pengukur level hidrostatik masing-masing memiliki keunggulan unik dalam pengukuran level industri. Pengukur level magnetik menawarkan indikasi visual yang sederhana, aman, dan sangat andal. Pengukur level hidrostatis memberikan output elektronik yang akurat dan hemat biaya untuk aplikasi konvensional.<\/p>\n<p data-start=\"4418\" data-end=\"4601\">Dengan memahami perbedaannya dan berkonsultasi dengan produsen pengukur level OEM yang berpengalaman, pengguna dapat memilih solusi pengukuran level yang paling sesuai untuk tangki dan bejana mereka.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Magnetic level gauges and hydrostatic level gauges are two widely used instruments for industrial liquid level monitoring. Both technologies are mature and reliable, but they serve different purposes and are suitable for different process conditions. From an OEM manufacturer\u2019s perspective, understanding the differences between a magnetic level gauge and a hydrostatic level gauge is&#8230;<\/p>","protected":false},"author":1,"featured_media":30542,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[295],"tags":[310,324,326,306,331,325,309],"class_list":["post-30541","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-level-gauge","tag-4-20ma-signal","tag-ce","tag-chemical-industry","tag-hydrostatic-pressure","tag-intrinsically-safe","tag-rohs","tag-working-principle"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava<\/title>\n<meta name=\"description\" content=\"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrava.com\/id\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava\" \/>\n<meta property=\"og:description\" content=\"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrava.com\/id\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Instrava\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-06T11:37:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-06T11:59:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Instrava\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ditulis oleh\" \/>\n\t<meta name=\"twitter:data1\" content=\"Instrava\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\"},\"author\":{\"name\":\"Instrava\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\"},\"headline\":\"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide\",\"datePublished\":\"2026-01-06T11:37:03+00:00\",\"dateModified\":\"2026-01-06T11:59:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\"},\"wordCount\":542,\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"keywords\":[\"4\u201320mA Signal\",\"CE\",\"Chemical Industry\",\"Hydrostatic Pressure\",\"Intrinsically Safe\",\"RoHS\",\"Working Principle\"],\"articleSection\":[\"Level Gauge\"],\"inLanguage\":\"id\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\",\"name\":\"Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"datePublished\":\"2026-01-06T11:37:03+00:00\",\"dateModified\":\"2026-01-06T11:59:25+00:00\",\"description\":\"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp\",\"width\":1200,\"height\":650,\"caption\":\"Magnetic level gauge vs hydrostatic level gauge comparison image, showing a magnetic level gauge on the left and a hydrostatic level transmitter on the right, highlighting differences in structure and level measurement methods.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrava.com\\\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrava.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Level Gauge\",\"item\":\"https:\\\/\\\/instrava.com\\\/category\\\/level-gauge\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"name\":\"instrava.com\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrava.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\",\"name\":\"instrava.com\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"width\":288,\"height\":59,\"caption\":\"instrava.com\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\",\"name\":\"Instrava\",\"sameAs\":[\"https:\\\/\\\/instrava.com\"],\"url\":\"https:\\\/\\\/instrava.com\\\/id\\\/author\\\/matrinpolergmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pengukur Level Magnetik vs Pengukur Level Hidrostatis - Instrava","description":"Bandingkan pengukur level magnetik dan pengukur level hidrostatik, dan pelajari bagaimana produsen OEM memilih pengukur level yang tepat untuk tangki industri.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrava.com\/id\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/","og_locale":"id_ID","og_type":"article","og_title":"Magnetic Level Gauge vs Hydrostatic Level Gauge - Instrava","og_description":"Compare magnetic level gauges and hydrostatic level gauges, and learn how OEM manufacturers choose the right level gauge for industrial tanks.","og_url":"https:\/\/instrava.com\/id\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/","og_site_name":"Instrava","article_published_time":"2026-01-06T11:37:03+00:00","article_modified_time":"2026-01-06T11:59:25+00:00","og_image":[{"width":1200,"height":650,"url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","type":"image\/webp"}],"author":"Instrava","twitter_card":"summary_large_image","twitter_misc":{"Ditulis oleh":"Instrava","Estimasi waktu membaca":"4 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#article","isPartOf":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/"},"author":{"name":"Instrava","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6"},"headline":"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide","datePublished":"2026-01-06T11:37:03+00:00","dateModified":"2026-01-06T11:59:25+00:00","mainEntityOfPage":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/"},"wordCount":542,"publisher":{"@id":"https:\/\/instrava.com\/#organization"},"image":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","keywords":["4\u201320mA Signal","CE","Chemical Industry","Hydrostatic Pressure","Intrinsically Safe","RoHS","Working Principle"],"articleSection":["Level Gauge"],"inLanguage":"id"},{"@type":"WebPage","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/","url":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/","name":"Pengukur Level Magnetik vs Pengukur Level Hidrostatis - Instrava","isPartOf":{"@id":"https:\/\/instrava.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage"},"image":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","datePublished":"2026-01-06T11:37:03+00:00","dateModified":"2026-01-06T11:59:25+00:00","description":"Bandingkan pengukur level magnetik dan pengukur level hidrostatik, dan pelajari bagaimana produsen OEM memilih pengukur level yang tepat untuk tangki industri.","breadcrumb":{"@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#primaryimage","url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/Magnetic-Level-Gauge-vs-Hydrostatic-Level-Gauge.webp","width":1200,"height":650,"caption":"Magnetic level gauge vs hydrostatic level gauge comparison image, showing a magnetic level gauge on the left and a hydrostatic level transmitter on the right, highlighting differences in structure and level measurement methods."},{"@type":"BreadcrumbList","@id":"https:\/\/instrava.com\/magnetic-level-gauge-vs-hydrostatic-level-gauge-technology-and-selection-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrava.com\/"},{"@type":"ListItem","position":2,"name":"Level Gauge","item":"https:\/\/instrava.com\/category\/level-gauge\/"},{"@type":"ListItem","position":3,"name":"Magnetic Level Gauge vs Hydrostatic Level Gauge: Technology and Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/instrava.com\/#website","url":"https:\/\/instrava.com\/","name":"instrava.com","description":"","publisher":{"@id":"https:\/\/instrava.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrava.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/instrava.com\/#organization","name":"instrava.com","url":"https:\/\/instrava.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","width":288,"height":59,"caption":"instrava.com"},"image":{"@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6","name":"Instrava","sameAs":["https:\/\/instrava.com"],"url":"https:\/\/instrava.com\/id\/author\/matrinpolergmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/posts\/30541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/comments?post=30541"}],"version-history":[{"count":0,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/posts\/30541\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/media\/30542"}],"wp:attachment":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/media?parent=30541"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/categories?post=30541"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/tags?post=30541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}