{"id":30856,"date":"2026-01-10T13:12:20","date_gmt":"2026-01-10T13:12:20","guid":{"rendered":"https:\/\/instrava.com\/?p=30856"},"modified":"2026-01-22T07:38:13","modified_gmt":"2026-01-22T07:38:13","slug":"types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide","status":"publish","type":"post","link":"https:\/\/instrava.com\/id\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/","title":{"rendered":"Jenis Pengukur Level Magnetik untuk Aplikasi Industri | Panduan Teknik"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30856\" class=\"elementor elementor-30856\" data-elementor-post-type=\"post\">\n\t\t\t\t\r\n\t\t<div class=\"default no-position show_shadow rs-sticky-default elementor-element elementor-element-3248c67b e-flex e-con-boxed e-con e-parent\" data-id=\"3248c67b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\r\n\t\t\t\t<div class=\"elementor-element elementor-element-5a760f99 elementor-widget elementor-widget-text-editor\" data-id=\"5a760f99\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"273\" data-end=\"541\">Magnetic level gauge technology is often discussed as a single category, but in real industrial practice, magnetic level gauges are available in multiple configurations, each optimized for specific process conditions, installation constraints, and safety requirements.<\/p>\r\n<p data-start=\"543\" data-end=\"869\">Understanding the different types of magnetic level gauge is essential for engineers responsible for liquid level indication in oil &amp; gas, LNG\/LPG storage, chemical processing, and other demanding environments. Selecting the wrong configuration can lead to reduced accuracy, mechanical stress, or long-term reliability issues.<\/p>\r\n<p data-start=\"871\" data-end=\"1039\">This article provides a structured overview of the main magnetic level gauge types used in industry and explains how each type supports different application scenarios.<\/p>\r\n\r\n\r\n<hr data-start=\"1041\" data-end=\"1044\" \/>\r\n\r\n<h2 data-start=\"1046\" data-end=\"1091\">Standard Side-Mounted Magnetic Level Gauge<\/h2>\r\n<p data-start=\"1093\" data-end=\"1311\">The most common configuration is the side-mounted magnetic level gauge. It is installed externally on a vessel using upper and lower process connections, allowing the chamber to mirror the liquid level inside the tank.<\/p>\r\n\r\n<h3 data-start=\"1313\" data-end=\"1340\">Typical characteristics<\/h3>\r\n<ul data-start=\"1341\" data-end=\"1476\">\r\n \t<li data-start=\"1341\" data-end=\"1366\">\r\n<p data-start=\"1343\" data-end=\"1366\">External bypass chamber<\/p>\r\n<\/li>\r\n \t<li data-start=\"1367\" data-end=\"1405\">\r\n<p data-start=\"1369\" data-end=\"1405\">Suitable for medium to large vessels<\/p>\r\n<\/li>\r\n \t<li data-start=\"1406\" data-end=\"1442\">\r\n<p data-start=\"1408\" data-end=\"1442\">Continuous visual level indication<\/p>\r\n<\/li>\r\n \t<li data-start=\"1443\" data-end=\"1476\">\r\n<p data-start=\"1445\" data-end=\"1476\">Easy inspection and maintenance<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"1478\" data-end=\"1501\">Common applications<\/h3>\r\n<ul data-start=\"1502\" data-end=\"1575\">\r\n \t<li data-start=\"1502\" data-end=\"1526\">\r\n<p data-start=\"1504\" data-end=\"1526\">Oil and gas separators<\/p>\r\n<\/li>\r\n \t<li data-start=\"1527\" data-end=\"1551\">\r\n<p data-start=\"1529\" data-end=\"1551\">Chemical storage tanks<\/p>\r\n<\/li>\r\n \t<li data-start=\"1552\" data-end=\"1575\">\r\n<p data-start=\"1554\" data-end=\"1575\">Utility water systems<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"1577\" data-end=\"1693\">This type is widely used because it provides a good balance between mechanical simplicity and measurement stability.<\/p>\r\n\r\n\r\n<hr data-start=\"1695\" data-end=\"1698\" \/>\r\n\r\n<h2 data-start=\"1700\" data-end=\"1735\">Top-Mounted Magnetic Level Gauge<\/h2>\r\n<p data-start=\"1737\" data-end=\"1877\">Top-mounted magnetic level gauges are installed from the top nozzle of a vessel, with the float suspended inside the chamber or guided pipe.<\/p>\r\n\r\n<h3 data-start=\"1879\" data-end=\"1921\">When top-mounted designs are preferred<\/h3>\r\n<ul data-start=\"1922\" data-end=\"2029\">\r\n \t<li data-start=\"1922\" data-end=\"1954\">\r\n<p data-start=\"1924\" data-end=\"1954\">Limited side nozzles available<\/p>\r\n<\/li>\r\n \t<li data-start=\"1955\" data-end=\"1987\">\r\n<p data-start=\"1957\" data-end=\"1987\">High-pressure vertical vessels<\/p>\r\n<\/li>\r\n \t<li data-start=\"1988\" data-end=\"2029\">\r\n<p data-start=\"1990\" data-end=\"2029\">Applications with internal obstructions<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"2031\" data-end=\"2166\">Because installation access differs from side-mounted designs, careful attention must be paid to float guidance and vertical alignment.<\/p>\r\n\r\n\r\n<hr data-start=\"2168\" data-end=\"2171\" \/>\r\n\r\n<h2 data-start=\"2173\" data-end=\"2222\">Magnetic Level Gauge with High-Pressure Design<\/h2>\r\n<p data-start=\"2224\" data-end=\"2365\">In high-pressure service, magnetic level gauges are engineered with reinforced chambers, pressure-rated flanges, and high-strength materials.<\/p>\r\n\r\n<h3 data-start=\"2367\" data-end=\"2398\">Typical pressure conditions<\/h3>\r\n<ul data-start=\"2399\" data-end=\"2484\">\r\n \t<li data-start=\"2399\" data-end=\"2420\">\r\n<p data-start=\"2401\" data-end=\"2420\">LNG and LPG storage<\/p>\r\n<\/li>\r\n \t<li data-start=\"2421\" data-end=\"2452\">\r\n<p data-start=\"2423\" data-end=\"2452\">Gas-liquid separation vessels<\/p>\r\n<\/li>\r\n \t<li data-start=\"2453\" data-end=\"2484\">\r\n<p data-start=\"2455\" data-end=\"2484\">Pressurized hydrocarbon tanks<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"2486\" data-end=\"2644\">High-pressure magnetic level gauges are often selected as a mechanical reference in systems where electronic instruments may be exposed to signal instability.<\/p>\r\n\r\n\r\n<hr data-start=\"2646\" data-end=\"2649\" \/>\r\n\r\n<h2 data-start=\"2651\" data-end=\"2684\">Cryogenic Magnetic Level Gauge<\/h2>\r\n<p data-start=\"2686\" data-end=\"2826\">Cryogenic magnetic level gauges are designed specifically for extremely low-temperature applications such as LNG or liquid nitrogen storage.<\/p>\r\n\r\n<h3 data-start=\"2828\" data-end=\"2851\">Key design features<\/h3>\r\n<ul data-start=\"2852\" data-end=\"2967\">\r\n \t<li data-start=\"2852\" data-end=\"2884\">\r\n<p data-start=\"2854\" data-end=\"2884\">Cryogenic-compatible materials<\/p>\r\n<\/li>\r\n \t<li data-start=\"2885\" data-end=\"2917\">\r\n<p data-start=\"2887\" data-end=\"2917\">Special float magnet selection<\/p>\r\n<\/li>\r\n \t<li data-start=\"2918\" data-end=\"2967\">\r\n<p data-start=\"2920\" data-end=\"2967\">Thermal isolation between process and indicator<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"2969\" data-end=\"3101\">At cryogenic temperatures, magnetic stability and material contraction must be carefully considered to maintain reliable indication.<\/p>\r\n\r\n\r\n<hr data-start=\"3103\" data-end=\"3106\" \/>\r\n\r\n<h2 data-start=\"3108\" data-end=\"3157\">Magnetic Level Gauge with Remote Signal Output<\/h2>\r\n<p data-start=\"3159\" data-end=\"3317\">While magnetic level gauges are inherently mechanical, many industrial installations require remote level signals for control systems or monitoring platforms.<\/p>\r\n<p data-start=\"3319\" data-end=\"3349\">This configuration integrates:<\/p>\r\n\r\n<ul data-start=\"3350\" data-end=\"3432\">\r\n \t<li data-start=\"3350\" data-end=\"3370\">\r\n<p data-start=\"3352\" data-end=\"3370\">Reed switch chains<\/p>\r\n<\/li>\r\n \t<li data-start=\"3371\" data-end=\"3397\">\r\n<p data-start=\"3373\" data-end=\"3397\">Sensor magnetostriktif<\/p>\r\n<\/li>\r\n \t<li data-start=\"3398\" data-end=\"3432\">\r\n<p data-start=\"3400\" data-end=\"3432\">Analog or digital signal outputs<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3434\" data-end=\"3577\">In these systems, the magnetic level gauge provides local visual confirmation, while the remote signal supports automation and alarm functions.<\/p>\r\n<p data-start=\"3579\" data-end=\"3742\">Instrava supports measurement architectures where mechanical indication and remote monitoring coexist, ensuring both operational visibility and system integration.<\/p>\r\n\r\n\r\n<hr data-start=\"3744\" data-end=\"3747\" \/>\r\n\r\n<h2 data-start=\"3749\" data-end=\"3805\">Magnetic Level Gauge for Corrosive or Hazardous Media<\/h2>\r\n<p data-start=\"3807\" data-end=\"3953\">For corrosive or toxic fluids, magnetic level gauges are constructed using specialized materials such as stainless steel alloys or lined chambers.<\/p>\r\n\r\n<h3 data-start=\"3955\" data-end=\"3977\">Key considerations<\/h3>\r\n<ul data-start=\"3978\" data-end=\"4097\">\r\n \t<li data-start=\"3978\" data-end=\"4021\">\r\n<p data-start=\"3980\" data-end=\"4021\">Material compatibility with process media<\/p>\r\n<\/li>\r\n \t<li data-start=\"4022\" data-end=\"4064\">\r\n<p data-start=\"4024\" data-end=\"4064\">Seal integrity under temperature cycling<\/p>\r\n<\/li>\r\n \t<li data-start=\"4065\" data-end=\"4097\">\r\n<p data-start=\"4067\" data-end=\"4097\">Long-term corrosion resistance<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"4099\" data-end=\"4223\">In hazardous environments, magnetic level gauges are often chosen to minimize direct operator exposure to the process fluid.<\/p>\r\n\r\n\r\n<hr data-start=\"4225\" data-end=\"4228\" \/>\r\n\r\n<h2 data-start=\"4230\" data-end=\"4273\">Comparison of Magnetic Level Gauge Types<\/h2>\r\n<div class=\"TyagGW_tableContainer\">\r\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\r\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4275\" data-end=\"4738\">\r\n<thead data-start=\"4275\" data-end=\"4327\">\r\n<tr data-start=\"4275\" data-end=\"4327\">\r\n<th data-start=\"4275\" data-end=\"4288\" data-col-size=\"sm\">Gauge Type<\/th>\r\n<th data-start=\"4288\" data-end=\"4310\" data-col-size=\"sm\">Aplikasi Khas<\/th>\r\n<th data-start=\"4310\" data-end=\"4327\" data-col-size=\"sm\">Key Advantage<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody data-start=\"4376\" data-end=\"4738\">\r\n<tr data-start=\"4376\" data-end=\"4428\">\r\n<td data-start=\"4376\" data-end=\"4391\" data-col-size=\"sm\">Side-mounted<\/td>\r\n<td data-start=\"4391\" data-end=\"4407\" data-col-size=\"sm\">Storage tanks<\/td>\r\n<td data-start=\"4407\" data-end=\"4428\" data-col-size=\"sm\">Instalasi mudah<\/td>\r\n<\/tr>\r\n<tr data-start=\"4429\" data-end=\"4488\">\r\n<td data-start=\"4429\" data-end=\"4443\" data-col-size=\"sm\">Dipasang di atas<\/td>\r\n<td data-start=\"4443\" data-end=\"4462\" data-col-size=\"sm\">Vertical vessels<\/td>\r\n<td data-start=\"4462\" data-end=\"4488\" data-col-size=\"sm\">No side nozzles needed<\/td>\r\n<\/tr>\r\n<tr data-start=\"4489\" data-end=\"4546\">\r\n<td data-start=\"4489\" data-end=\"4505\" data-col-size=\"sm\">High-pressure<\/td>\r\n<td data-start=\"4505\" data-end=\"4523\" data-col-size=\"sm\">LPG\/LNG systems<\/td>\r\n<td data-start=\"4523\" data-end=\"4546\" data-col-size=\"sm\">Mechanical strength<\/td>\r\n<\/tr>\r\n<tr data-start=\"4547\" data-end=\"4600\">\r\n<td data-start=\"4547\" data-end=\"4559\" data-col-size=\"sm\">Cryogenic<\/td>\r\n<td data-start=\"4559\" data-end=\"4571\" data-col-size=\"sm\">LNG tanks<\/td>\r\n<td data-start=\"4571\" data-end=\"4600\" data-col-size=\"sm\">Low-temperature stability<\/td>\r\n<\/tr>\r\n<tr data-start=\"4601\" data-end=\"4670\">\r\n<td data-start=\"4601\" data-end=\"4622\" data-col-size=\"sm\">With remote output<\/td>\r\n<td data-start=\"4622\" data-end=\"4641\" data-col-size=\"sm\">Automated plants<\/td>\r\n<td data-col-size=\"sm\" data-start=\"4641\" data-end=\"4670\">Local + remote indication<\/td>\r\n<\/tr>\r\n<tr data-start=\"4671\" data-end=\"4738\">\r\n<td data-start=\"4671\" data-end=\"4693\" data-col-size=\"sm\">Corrosion-resistant<\/td>\r\n<td data-start=\"4693\" data-end=\"4715\" data-col-size=\"sm\">Pemrosesan kimia<\/td>\r\n<td data-start=\"4715\" data-end=\"4738\" data-col-size=\"sm\">Media compatibility<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table><\/div>\r\n<\/div>\r\n<\/div>\r\n\r\n<hr data-start=\"4740\" data-end=\"4743\" \/>\r\n\r\n<h2 data-start=\"4745\" data-end=\"4791\">Selection Challenges Across Different Types<\/h2>\r\n<p data-start=\"4793\" data-end=\"4892\">Although magnetic level gauges are robust, selection errors still occur. Common challenges include:<\/p>\r\n\r\n<ul data-start=\"4893\" data-end=\"5089\">\r\n \t<li data-start=\"4893\" data-end=\"4935\">\r\n<p data-start=\"4895\" data-end=\"4935\">Incorrect float design for fluid density<\/p>\r\n<\/li>\r\n \t<li data-start=\"4936\" data-end=\"4995\">\r\n<p data-start=\"4938\" data-end=\"4995\">Underestimating temperature effects on magnet performance<\/p>\r\n<\/li>\r\n \t<li data-start=\"4996\" data-end=\"5038\">\r\n<p data-start=\"4998\" data-end=\"5038\">Choosing inappropriate chamber materials<\/p>\r\n<\/li>\r\n \t<li data-start=\"5039\" data-end=\"5089\">\r\n<p data-start=\"5041\" data-end=\"5089\">Overlooking installation orientation constraints<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"5091\" data-end=\"5184\">Addressing these factors early in the design phase helps ensure reliable long-term operation.<\/p>\r\n\r\n\r\n<hr data-start=\"5186\" data-end=\"5189\" \/>\r\n\r\n<h2 data-start=\"5191\" data-end=\"5252\">Why Multiple Magnetic Level Gauge Types Are Still Relevant<\/h2>\r\n<p data-start=\"5254\" data-end=\"5475\">Modern industrial plants rarely rely on a single measurement technology. Different magnetic level gauge types allow engineers to adapt the same core principle to a wide range of conditions without sacrificing reliability.<\/p>\r\n<p data-start=\"5477\" data-end=\"5571\">Rather than competing with electronic level instruments, magnetic level gauges often serve as:<\/p>\r\n\r\n<ul data-start=\"5572\" data-end=\"5674\">\r\n \t<li data-start=\"5572\" data-end=\"5603\">\r\n<p data-start=\"5574\" data-end=\"5603\">Independent visual references<\/p>\r\n<\/li>\r\n \t<li data-start=\"5604\" data-end=\"5633\">\r\n<p data-start=\"5606\" data-end=\"5633\">Redundant safety indicators<\/p>\r\n<\/li>\r\n \t<li data-start=\"5634\" data-end=\"5674\">\r\n<p data-start=\"5636\" data-end=\"5674\">Stable benchmarks during system upsets<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"5676\" data-end=\"5892\">Instrava approaches level measurement with a focus on process conditions, long-term reliability, and engineering collaboration, ensuring that the selected magnetic level gauge type aligns with real operational needs.<\/p>\r\n\r\n\r\n<hr data-start=\"5894\" data-end=\"5897\" \/>\r\n\r\n<h2 data-start=\"5899\" data-end=\"5912\">Kesimpulan<\/h2>\r\n<p data-start=\"5914\" data-end=\"6099\">Magnetic level gauge technology is not one-size-fits-all. Side-mounted, top-mounted, high-pressure, cryogenic, and signal-integrated designs each address specific industrial challenges.<\/p>\r\n<p data-start=\"6101\" data-end=\"6333\">By understanding the different types of magnetic level gauge and their intended applications, engineers can improve safety, reduce maintenance risk, and ensure consistent level indication across a wide range of industrial processes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Magnetic level gauge technology is often discussed as a single category, but in real industrial practice, magnetic level gauges are available in multiple configurations, each optimized for specific process conditions, installation constraints, and safety requirements. Understanding the different types of magnetic level gauge is essential for engineers responsible for liquid level indication in oil &amp;&#8230;<\/p>","protected":false},"author":1,"featured_media":30857,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[295],"tags":[513,510,514,511,512,343,515,367,415],"class_list":["post-30856","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-level-gauge","tag-chemical-process-measurement","tag-industrial-level-measurement","tag-level-gauge-selection","tag-liquid-level-indication","tag-lng-lpg-level-gauge","tag-magnetic-level-gauge","tag-mechanical-level-gauge","tag-oil-and-gas-instrumentation","tag-process-safety-instrumentation"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Types of Magnetic Level Gauge for Industrial Applications - Instrava<\/title>\n<meta name=\"description\" content=\"Explore different magnetic level gauge types and how they support safe, reliable level measurement in oil, gas, LNG, and chemical processes. Instrava focuses on practical engineering solutions built for long-term operation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrava.com\/id\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Types of Magnetic Level Gauge for Industrial Applications - Instrava\" \/>\n<meta property=\"og:description\" content=\"Explore different magnetic level gauge types and how they support safe, reliable level measurement in oil, gas, LNG, and chemical processes. Instrava focuses on practical engineering solutions built for long-term operation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrava.com\/id\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Instrava\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-10T13:12:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-22T07:38:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/magnetic-level-gauges.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Instrava\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ditulis oleh\" \/>\n\t<meta name=\"twitter:data1\" content=\"Instrava\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/\"},\"author\":{\"name\":\"Instrava\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\"},\"headline\":\"Types of Magnetic Level Gauge for Industrial Applications | Engineering Guide\",\"datePublished\":\"2026-01-10T13:12:20+00:00\",\"dateModified\":\"2026-01-22T07:38:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/\"},\"wordCount\":757,\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/magnetic-level-gauges.webp\",\"keywords\":[\"chemical process measurement\",\"industrial level measurement\",\"level gauge selection\",\"liquid level indication\",\"LNG LPG level gauge\",\"magnetic level gauge\",\"mechanical level gauge\",\"oil and gas instrumentation\",\"process safety instrumentation\"],\"articleSection\":[\"Level Gauge\"],\"inLanguage\":\"id\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/\",\"name\":\"Types of Magnetic Level Gauge for Industrial Applications - Instrava\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/magnetic-level-gauges.webp\",\"datePublished\":\"2026-01-10T13:12:20+00:00\",\"dateModified\":\"2026-01-22T07:38:13+00:00\",\"description\":\"Explore different magnetic level gauge types and how they support safe, reliable level measurement in oil, gas, LNG, and chemical processes. Instrava focuses on practical engineering solutions built for long-term operation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/magnetic-level-gauges.webp\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/magnetic-level-gauges.webp\",\"width\":1200,\"height\":650,\"caption\":\"Magnetic level gauge - Rope type - Side mounted - Top mounted\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrava.com\\\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrava.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Level Gauge\",\"item\":\"https:\\\/\\\/instrava.com\\\/category\\\/level-gauge\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Types of Magnetic Level Gauge for Industrial Applications | Engineering Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"name\":\"instrava.com\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrava.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\",\"name\":\"instrava.com\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"width\":288,\"height\":59,\"caption\":\"instrava.com\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\",\"name\":\"Instrava\",\"sameAs\":[\"https:\\\/\\\/instrava.com\"],\"url\":\"https:\\\/\\\/instrava.com\\\/id\\\/author\\\/matrinpolergmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Types of Magnetic Level Gauge for Industrial Applications - Instrava","description":"Explore different magnetic level gauge types and how they support safe, reliable level measurement in oil, gas, LNG, and chemical processes. Instrava focuses on practical engineering solutions built for long-term operation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrava.com\/id\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/","og_locale":"id_ID","og_type":"article","og_title":"Types of Magnetic Level Gauge for Industrial Applications - Instrava","og_description":"Explore different magnetic level gauge types and how they support safe, reliable level measurement in oil, gas, LNG, and chemical processes. Instrava focuses on practical engineering solutions built for long-term operation.","og_url":"https:\/\/instrava.com\/id\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/","og_site_name":"Instrava","article_published_time":"2026-01-10T13:12:20+00:00","article_modified_time":"2026-01-22T07:38:13+00:00","og_image":[{"width":1200,"height":650,"url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/magnetic-level-gauges.webp","type":"image\/webp"}],"author":"Instrava","twitter_card":"summary_large_image","twitter_misc":{"Ditulis oleh":"Instrava","Estimasi waktu membaca":"5 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/#article","isPartOf":{"@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/"},"author":{"name":"Instrava","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6"},"headline":"Types of Magnetic Level Gauge for Industrial Applications | Engineering Guide","datePublished":"2026-01-10T13:12:20+00:00","dateModified":"2026-01-22T07:38:13+00:00","mainEntityOfPage":{"@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/"},"wordCount":757,"publisher":{"@id":"https:\/\/instrava.com\/#organization"},"image":{"@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/magnetic-level-gauges.webp","keywords":["chemical process measurement","industrial level measurement","level gauge selection","liquid level indication","LNG LPG level gauge","magnetic level gauge","mechanical level gauge","oil and gas instrumentation","process safety instrumentation"],"articleSection":["Level Gauge"],"inLanguage":"id"},{"@type":"WebPage","@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/","url":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/","name":"Types of Magnetic Level Gauge for Industrial Applications - Instrava","isPartOf":{"@id":"https:\/\/instrava.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/#primaryimage"},"image":{"@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/magnetic-level-gauges.webp","datePublished":"2026-01-10T13:12:20+00:00","dateModified":"2026-01-22T07:38:13+00:00","description":"Explore different magnetic level gauge types and how they support safe, reliable level measurement in oil, gas, LNG, and chemical processes. Instrava focuses on practical engineering solutions built for long-term operation.","breadcrumb":{"@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/#primaryimage","url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/magnetic-level-gauges.webp","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/magnetic-level-gauges.webp","width":1200,"height":650,"caption":"Magnetic level gauge - Rope type - Side mounted - Top mounted"},{"@type":"BreadcrumbList","@id":"https:\/\/instrava.com\/types-of-magnetic-level-gauge-for-industrial-applications-engineering-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrava.com\/"},{"@type":"ListItem","position":2,"name":"Level Gauge","item":"https:\/\/instrava.com\/category\/level-gauge\/"},{"@type":"ListItem","position":3,"name":"Types of Magnetic Level Gauge for Industrial Applications | Engineering Guide"}]},{"@type":"WebSite","@id":"https:\/\/instrava.com\/#website","url":"https:\/\/instrava.com\/","name":"instrava.com","description":"","publisher":{"@id":"https:\/\/instrava.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrava.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/instrava.com\/#organization","name":"instrava.com","url":"https:\/\/instrava.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","width":288,"height":59,"caption":"instrava.com"},"image":{"@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6","name":"Instrava","sameAs":["https:\/\/instrava.com"],"url":"https:\/\/instrava.com\/id\/author\/matrinpolergmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/posts\/30856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/comments?post=30856"}],"version-history":[{"count":0,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/posts\/30856\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/media\/30857"}],"wp:attachment":[{"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/media?parent=30856"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/categories?post=30856"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrava.com\/id\/wp-json\/wp\/v2\/tags?post=30856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}