Оптический анализ

Fully Automatic UV Spectrophotometric Oil Analyzer

Transform Oil-in-Water Testing with True Full Automation

In modern environmental monitoring, accuracy alone is not enough—efficiency, safety, and consistency are equally critical. This fully automatic UV spectrophotometric oil analyzer redefines oil content testing by delivering a completely automated workflow, from sampling to final reporting.

No manual extraction. No operator exposure to solvents. No compromise on accuracy.

С UV 225nm detection aligned with environmental standards, the system ensures every measurement is traceable, repeatable, and compliant, making it the ideal solution for:

  • Станции экологического мониторинга
  • Wastewater treatment plants
  • Petrochemical and energy industries
  • Government compliance laboratories

  Optical Analysis Description  

Intelligent Automation Meets High-Precision UV Detection

At the core of this system is a high-performance UV optical platform, optimized for low detection limits and stable long-term operation.

Key performance advantages include:

  • UV 225nm spectrophotometric method for standardized oil detection
  • Automatic extraction, separation, dehydration, and measurement
  • High-sensitivity UV detector for trace-level oil detection (down to 0.01 mg/L)
  • Automatic wavelength calibration & zero correction to eliminate drift
  • Расширенный noise suppression circuit for enhanced signal clarity

The analyzer strictly follows the Lambert-Beer law, ensuring that absorbance correlates precisely with oil concentration, delivering high linearity (R > 0.999) even across varying sample conditions.

UV spectrophotometric oil analyzer for oil in water measurement system
Fully automatic UV spectrophotometric oil analyzer for water quality testing laboratory

Built for Real-World Industrial Applications

This is not just a lab instrument—it is a complete solution engineered for real working environments.

Designed with application-driven intelligence, it offers:

  • Fully automated batch processing (up to 10 samples) for high-throughput labs
  • Integrated solvent purity detection to prevent measurement errors
  • Magnesium silicate adsorption system to eliminate interference from non-petroleum oils
  • Real-time monitoring of adsorption column life with optional auto-switching backup
  • Oil-water separation membrane for longer lifespan and reduced maintenance

The embedded system provides:

  • Touchscreen control (no PC required)
  • Real-time display of concentration, absorbance, and wavelength
  • Data storage, statistical analysis, and report generation

This ensures consistent results, reduced labor cost, and improved operational safety, even in demanding industrial environments.

  Optical Analysis Parameter  

ПараметрТехнические характеристики
Detection MethodUV Spectrophotometry (225 nm)
Detection Limit0,01 мг/л
Диапазон измерений0–16 mg/L
Точность≤±10% (@1.0 mg/L)
ПовторяемостьRSD ≤3% (@1.0 mg/L)
LinearityR > 0.999
Wavelength Range190–1100 nm
Absorbance Range0.00000–3.00000 AU
Automatic SamplingUp to 10 samples
КалибровкаAutomatic wavelength & zero calibration
ОперацияFully automatic + touchscreen system

  Instrava OEM/ODM  

Reliable Instruments. Solutions That Fit Your Application.

Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.

By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

символизирует доверие и начало долгосрочного партнерства

  Рекомендации по сопутствующим товарам  

A fully automatic UV spectrophotometric oil analyzer is used to measure petroleum hydrocarbons in water with minimal human intervention. It is critical for environmental compliance, wastewater monitoring, and industrial discharge control, ensuring accurate and standardized oil detection.

Automation eliminates human errors in:

  • Sample handling
  • Solvent extraction
  • Measurement timing

This results in:

  • Higher repeatability (RSD ≤3%)
  • Reduced contamination risk
  • Faster multi-sample processing

This analyzer is widely used in:

  • Агентства по мониторингу окружающей среды
  • Wastewater treatment facilities
  • Oil & gas and petrochemical industries
  • Power plants and steel manufacturing

These sectors require reliable oil content measurement for regulatory compliance.

With a detection limit of 0,01 мг/л, the analyzer can detect trace oil contamination, which is essential for:

  • Clean water compliance
  • Early pollution detection
  • High-precision laboratory analysis

The analyzer uses a magnesium silicate adsorption column to remove animal and vegetable oils, ensuring that only petroleum hydrocarbons are measured. This significantly improves accuracy and compliance with standard methods.

Yes. The system is designed for maximum safety, featuring:

  • Fully enclosed extraction process
  • No direct contact with organic solvents
  • Automatic cleaning to prevent cross-contamination

This makes it ideal for continuous industrial and laboratory operation.

Тепловые, вихревые, дифференциальные: как выбрать правильную технологию измерения расхода

  • По ссылке Instrava
  • 25 Фев, 2026

Выбор расходомера редко сводится только к точности. В промышленных приложениях реальные проблемы включают в себя: Переменные расходы Давление...

  • 1Min Read

Расходомер с овальной шестерней: Почему он по-прежнему доминирует в современной автоматизации при измерении высоковязких потоков

  • По ссылке Instrava
  • 28 января 2026 года

В эпоху, когда умные датчики, цифровые двойники и приборы, управляемые искусственным интеллектом, доминируют...

  • 2Мин Чтение

Портативные ультразвуковые расходомеры - точное измерение расхода в промышленности

  • По ссылке Instrava
  • 22 января 2026 года

Портативные ультразвуковые расходомеры - точные промышленные измерения расхода | Instrava Портативные ультразвуковые расходомеры Обзор Портативные ультразвуковые расходомеры...

  • 1Min Read

Почему стоит выбрать Instrava

Built on Consistency, Not Claims

Focused on Industrial Applications

We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.

Strict Product Selection Criteria

Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.

Reliable Supply & Quality Consistency

We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.

Practical, Experience-Based Support

Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.

Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.

Сцена промышленного измерения, на которой рабочий использует точный измерительный прибор для измерения и маркировки материала на верстаке, демонстрирует практическое применение измерительных приборов в производстве и обработке.
Главная
Продукция
Whatsapp