{"id":30615,"date":"2026-01-07T07:25:11","date_gmt":"2026-01-07T07:25:11","guid":{"rendered":"https:\/\/instrava.com\/?p=30615"},"modified":"2026-01-22T07:32:33","modified_gmt":"2026-01-22T07:32:33","slug":"how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants","status":"publish","type":"post","link":"https:\/\/instrava.com\/ru\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/","title":{"rendered":"\u041a\u0430\u043a \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u0439 \u0440\u0430\u0441\u0445\u043e\u0434\u043e\u043c\u0435\u0440 \u0434\u043b\u044f \u043d\u0435\u0444\u0442\u044f\u043d\u044b\u0445, \u0433\u0430\u0437\u043e\u0432\u044b\u0445 \u0438\u043b\u0438 \u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0437\u0430\u0432\u043e\u0434\u043e\u0432?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30615\" class=\"elementor elementor-30615\" data-elementor-post-type=\"post\">\n\t\t\t\t\r\n\t\t<div class=\"default no-position show_shadow rs-sticky-default elementor-element elementor-element-73d97e8e e-flex e-con-boxed e-con e-parent\" data-id=\"73d97e8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\r\n\t\t\t\t<div class=\"elementor-element elementor-element-44fc79c elementor-widget elementor-widget-text-editor\" data-id=\"44fc79c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2 data-start=\"287\" data-end=\"742\">Flow Meter Selection Guide | Oil, Gas &amp; Chemical Plant Applications<\/h2>\n<p data-start=\"287\" data-end=\"742\">Accurate flow measurement is a critical component of industrial process control. In oil, gas, and chemical plants, flow meters are essential for monitoring liquids, gases, and slurries to ensure process efficiency, safety, and compliance with environmental standards. Selecting the right flow meter for your application requires careful consideration of fluid properties, process conditions, installation requirements, and operational goals.<\/p>\n<p data-start=\"744\" data-end=\"903\">This guide provides a structured approach to selecting flow meters for industrial applications, helping engineers and process managers make informed decisions.<\/p>\n\n\n<hr data-start=\"905\" data-end=\"908\" \/>\n\n<h2 data-start=\"910\" data-end=\"955\">Why Selecting the Right Flow Meter Matters<\/h2>\n<p data-start=\"957\" data-end=\"1057\">Flow measurement is the backbone of industrial automation. A poorly chosen flow meter can lead to:<\/p>\n\n<ul data-start=\"1059\" data-end=\"1193\">\n \t<li data-start=\"1059\" data-end=\"1087\">\n<p data-start=\"1061\" data-end=\"1087\">Inaccurate flow readings<\/p>\n<\/li>\n \t<li data-start=\"1088\" data-end=\"1118\">\n<p data-start=\"1090\" data-end=\"1118\">\u0421\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430<\/p>\n<\/li>\n \t<li data-start=\"1119\" data-end=\"1150\">\n<p data-start=\"1121\" data-end=\"1150\">Increased operational costs<\/p>\n<\/li>\n \t<li data-start=\"1151\" data-end=\"1193\">\n<p data-start=\"1153\" data-end=\"1193\">Safety risks in hazardous environments<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1195\" data-end=\"1476\">In industries such as oil refining, chemical processing, and natural gas distribution, flow meters are used for custody transfer, inventory management, chemical dosing, and process optimization. Selecting the correct meter ensures reliable operation and long-term cost savings.<\/p>\n\n\n<hr data-start=\"1478\" data-end=\"1481\" \/>\n\n<h2 data-start=\"1483\" data-end=\"1537\">Key Factors to Consider When Selecting a Flow Meter<\/h2>\n<h3 data-start=\"1539\" data-end=\"1571\">1. Fluid Type and Properties<\/h3>\n<p data-start=\"1573\" data-end=\"1650\">The first step in selection is understanding the <strong data-start=\"1622\" data-end=\"1647\">fluid characteristics<\/strong>:<\/p>\n\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1652\" data-end=\"2140\">\n<thead data-start=\"1652\" data-end=\"1678\">\n<tr data-start=\"1652\" data-end=\"1678\">\n<th data-start=\"1652\" data-end=\"1661\" data-col-size=\"sm\">\u0424\u0430\u043a\u0442\u043e\u0440<\/th>\n<th data-start=\"1661\" data-end=\"1678\" data-col-size=\"md\">\u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0435\u043d\u0438\u0435<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1706\" data-end=\"2140\">\n<tr data-start=\"1706\" data-end=\"1740\">\n<td data-start=\"1706\" data-end=\"1714\" data-col-size=\"sm\">Phase<\/td>\n<td data-start=\"1714\" data-end=\"1740\" data-col-size=\"md\">Liquid, gas, or slurry<\/td>\n<\/tr>\n<tr data-start=\"1741\" data-end=\"1831\">\n<td data-start=\"1741\" data-end=\"1753\" data-col-size=\"sm\">\u0412\u044f\u0437\u043a\u043e\u0441\u0442\u044c<\/td>\n<td data-start=\"1753\" data-end=\"1831\" data-col-size=\"md\">High viscosity fluids may require Coriolis or positive displacement meters<\/td>\n<\/tr>\n<tr data-start=\"1832\" data-end=\"1907\">\n<td data-start=\"1832\" data-end=\"1847\" data-col-size=\"sm\">\u041f\u0440\u043e\u0432\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c<\/td>\n<td data-start=\"1847\" data-end=\"1907\" data-col-size=\"md\">Required for electromagnetic meters (must be conductive)<\/td>\n<\/tr>\n<tr data-start=\"1908\" data-end=\"1985\">\n<td data-start=\"1908\" data-end=\"1924\" data-col-size=\"sm\">Corrosiveness<\/td>\n<td data-start=\"1924\" data-end=\"1985\" data-col-size=\"md\">Material compatibility with chemical or aggressive fluids<\/td>\n<\/tr>\n<tr data-start=\"1986\" data-end=\"2071\">\n<td data-start=\"1986\" data-end=\"2000\" data-col-size=\"sm\">\u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430<\/td>\n<td data-start=\"2000\" data-end=\"2071\" data-col-size=\"md\">Extreme temperatures may require high-grade materials or insulation<\/td>\n<\/tr>\n<tr data-start=\"2072\" data-end=\"2140\">\n<td data-start=\"2072\" data-end=\"2083\" data-col-size=\"sm\">\u0414\u0430\u0432\u043b\u0435\u043d\u0438\u0435<\/td>\n<td data-start=\"2083\" data-end=\"2140\" data-col-size=\"md\">Operating pressure affects meter selection and safety<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n\n<hr data-start=\"2142\" data-end=\"2145\" \/>\n\n<h3 data-start=\"2147\" data-end=\"2173\">2. Flow Rate and Range<\/h3>\n<p data-start=\"2175\" data-end=\"2261\">The flow meter must operate accurately across the expected flow range. Consider:<\/p>\n\n<ul data-start=\"2263\" data-end=\"2366\">\n \t<li data-start=\"2263\" data-end=\"2297\">\n<p data-start=\"2265\" data-end=\"2297\">\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0441\u0445\u043e\u0434<\/p>\n<\/li>\n \t<li data-start=\"2298\" data-end=\"2329\">\n<p data-start=\"2300\" data-end=\"2329\">Flow profile and turbulence<\/p>\n<\/li>\n \t<li data-start=\"2330\" data-end=\"2366\">\n<p data-start=\"2332\" data-end=\"2366\">Intermittent vs. continuous flow<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2368\" data-end=\"2563\">For example, a turbine flow meter may work well for clean, consistent liquid flow, but Coriolis meters are better for fluctuating flow rates or mass flow measurement in chemical reactors.<\/p>\n\n\n<hr data-start=\"2565\" data-end=\"2568\" \/>\n\n<h3 data-start=\"2570\" data-end=\"2609\">3. Pipe Size and Installation Space<\/h3>\n<ul data-start=\"2611\" data-end=\"2826\">\n \t<li data-start=\"2611\" data-end=\"2675\">\n<p data-start=\"2613\" data-end=\"2675\">Verify pipe diameter compatibility with the flow meter type.<\/p>\n<\/li>\n \t<li data-start=\"2676\" data-end=\"2768\">\n<p data-start=\"2678\" data-end=\"2768\">Ensure there is sufficient straight pipe upstream and downstream to minimize turbulence.<\/p>\n<\/li>\n \t<li data-start=\"2769\" data-end=\"2826\">\n<p data-start=\"2771\" data-end=\"2826\">Consider accessibility for maintenance and calibration.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2828\" data-end=\"2895\"><strong data-start=\"2828\" data-end=\"2895\">Recommended Straight Pipe Lengths for Common Flow Meters<\/strong><\/p>\n\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2897\" data-end=\"3134\">\n<thead data-start=\"2897\" data-end=\"2940\">\n<tr data-start=\"2897\" data-end=\"2940\">\n<th data-start=\"2897\" data-end=\"2915\" data-col-size=\"sm\">Flow Meter Type<\/th>\n<th data-start=\"2915\" data-end=\"2926\" data-col-size=\"sm\">Upstream<\/th>\n<th data-start=\"2926\" data-end=\"2940\" data-col-size=\"sm\">Downstream<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2986\" data-end=\"3134\">\n<tr data-start=\"2986\" data-end=\"3024\">\n<td data-start=\"2986\" data-end=\"3010\" data-col-size=\"sm\">Differential Pressure<\/td>\n<td data-start=\"3010\" data-end=\"3017\" data-col-size=\"sm\">10\u00d7D<\/td>\n<td data-start=\"3017\" data-end=\"3024\" data-col-size=\"sm\">5\u00d7D<\/td>\n<\/tr>\n<tr data-start=\"3025\" data-end=\"3056\">\n<td data-start=\"3025\" data-end=\"3043\" data-col-size=\"sm\">\u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439<\/td>\n<td data-start=\"3043\" data-end=\"3049\" data-col-size=\"sm\">5\u00d7D<\/td>\n<td data-start=\"3049\" data-end=\"3056\" data-col-size=\"sm\">3\u00d7D<\/td>\n<\/tr>\n<tr data-start=\"3057\" data-end=\"3084\">\n<td data-start=\"3057\" data-end=\"3070\" data-col-size=\"sm\">\u0423\u043b\u044c\u0442\u0440\u0430\u0437\u0432\u0443\u043a\u043e\u0432\u043e\u0439<\/td>\n<td data-start=\"3070\" data-end=\"3077\" data-col-size=\"sm\">10\u00d7D<\/td>\n<td data-start=\"3077\" data-end=\"3084\" data-col-size=\"sm\">5\u00d7D<\/td>\n<\/tr>\n<tr data-start=\"3085\" data-end=\"3109\">\n<td data-start=\"3085\" data-end=\"3096\" data-col-size=\"sm\">\u041a\u043e\u0440\u0438\u043e\u043b\u0438\u0441<\/td>\n<td data-start=\"3096\" data-end=\"3102\" data-col-size=\"sm\">3\u00d7D<\/td>\n<td data-start=\"3102\" data-end=\"3109\" data-col-size=\"sm\">3\u00d7D<\/td>\n<\/tr>\n<tr data-start=\"3110\" data-end=\"3134\">\n<td data-start=\"3110\" data-end=\"3120\" data-col-size=\"sm\">Turbine<\/td>\n<td data-start=\"3120\" data-end=\"3127\" data-col-size=\"sm\">10\u00d7D<\/td>\n<td data-start=\"3127\" data-end=\"3134\" data-col-size=\"sm\">5\u00d7D<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<blockquote data-start=\"3136\" data-end=\"3155\">\n<p data-start=\"3138\" data-end=\"3155\">D = Pipe Diameter<\/p>\n<\/blockquote>\n\n<hr data-start=\"3157\" data-end=\"3160\" \/>\n\n<h3 data-start=\"3162\" data-end=\"3190\">4. Accuracy Requirements<\/h3>\n<p data-start=\"3192\" data-end=\"3352\">Industrial processes often demand high accuracy to ensure proper dosing, quality, and energy efficiency. Typical accuracy ranges for industrial flow meters:<\/p>\n\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3354\" data-end=\"3538\">\n<thead data-start=\"3354\" data-end=\"3379\">\n<tr data-start=\"3354\" data-end=\"3379\">\n<th data-start=\"3354\" data-end=\"3367\" data-col-size=\"sm\">Meter Type<\/th>\n<th data-start=\"3367\" data-end=\"3379\" data-col-size=\"sm\">\u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3406\" data-end=\"3538\">\n<tr data-start=\"3406\" data-end=\"3430\">\n<td data-start=\"3406\" data-end=\"3417\" data-col-size=\"sm\">\u041a\u043e\u0440\u0438\u043e\u043b\u0438\u0441<\/td>\n<td data-start=\"3417\" data-end=\"3430\" data-col-size=\"sm\">\u00b10,1-0,2%<\/td>\n<\/tr>\n<tr data-start=\"3431\" data-end=\"3467\">\n<td data-start=\"3431\" data-end=\"3455\" data-col-size=\"sm\">Differential Pressure<\/td>\n<td data-start=\"3455\" data-end=\"3467\" data-col-size=\"sm\">\u00b10.25\u20131%<\/td>\n<\/tr>\n<tr data-start=\"3468\" data-end=\"3497\">\n<td data-start=\"3468\" data-end=\"3486\" data-col-size=\"sm\">\u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439<\/td>\n<td data-start=\"3486\" data-end=\"3497\" data-col-size=\"sm\">\u00b10,5-1%<\/td>\n<\/tr>\n<tr data-start=\"3498\" data-end=\"3518\">\n<td data-start=\"3498\" data-end=\"3511\" data-col-size=\"sm\">\u0423\u043b\u044c\u0442\u0440\u0430\u0437\u0432\u0443\u043a\u043e\u0432\u043e\u0439<\/td>\n<td data-start=\"3511\" data-end=\"3518\" data-col-size=\"sm\">\u00b11%<\/td>\n<\/tr>\n<tr data-start=\"3519\" data-end=\"3538\">\n<td data-start=\"3519\" data-end=\"3529\" data-col-size=\"sm\">Turbine<\/td>\n<td data-start=\"3529\" data-end=\"3538\" data-col-size=\"sm\">\u00b10.5%<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n<p data-start=\"3540\" data-end=\"3642\">Choose a meter type that meets your process requirements without overpaying for unnecessary precision.<\/p>\n\n\n<hr data-start=\"3644\" data-end=\"3647\" \/>\n\n<h3 data-start=\"3649\" data-end=\"3695\">5. Environmental and Safety Considerations<\/h3>\n<p data-start=\"3697\" data-end=\"3757\">Industrial environments can be harsh. Key factors include:<\/p>\n\n<ul data-start=\"3759\" data-end=\"3911\">\n \t<li data-start=\"3759\" data-end=\"3783\">\n<p data-start=\"3761\" data-end=\"3783\">\u042d\u043a\u0441\u0442\u0440\u0435\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b<\/p>\n<\/li>\n \t<li data-start=\"3784\" data-end=\"3806\">\n<p data-start=\"3786\" data-end=\"3806\">Vibration or shock<\/p>\n<\/li>\n \t<li data-start=\"3807\" data-end=\"3851\">\n<p data-start=\"3809\" data-end=\"3851\">Dust, moisture, or corrosive atmospheres<\/p>\n<\/li>\n \t<li data-start=\"3852\" data-end=\"3911\">\n<p data-start=\"3854\" data-end=\"3911\">Hazardous area requirements (ATEX, IECEx certification)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3913\" data-end=\"4029\"><strong data-start=\"3913\" data-end=\"3925\">\u041f\u0440\u0438\u043c\u0435\u0440:<\/strong> Oil &amp; gas pipelines often require explosion-proof flow meters certified for flammable gases or liquids.<\/p>\n\n\n<hr data-start=\"4031\" data-end=\"4034\" \/>\n\n<h3 data-start=\"4036\" data-end=\"4072\">6. Communication and Integration<\/h3>\n<p data-start=\"4074\" data-end=\"4151\">Modern industrial automation relies on digital communication protocols:<\/p>\n\n<ul data-start=\"4153\" data-end=\"4270\">\n \t<li data-start=\"4153\" data-end=\"4178\">\n<p data-start=\"4155\" data-end=\"4178\">4\u201320 mA analog output<\/p>\n<\/li>\n \t<li data-start=\"4179\" data-end=\"4196\">\n<p data-start=\"4181\" data-end=\"4196\">\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b HART<\/p>\n<\/li>\n \t<li data-start=\"4197\" data-end=\"4228\">\n<p data-start=\"4199\" data-end=\"4228\">Modbus, FOUNDATION Fieldbus<\/p>\n<\/li>\n \t<li data-start=\"4229\" data-end=\"4270\">\n<p data-start=\"4231\" data-end=\"4270\">Integration with SCADA or DCS systems<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4272\" data-end=\"4392\">Smart flow meters can also provide diagnostics, alerts, and remote calibration, reducing downtime and maintenance costs.<\/p>\n\n\n<hr data-start=\"4394\" data-end=\"4397\" \/>\n\n<h2 data-start=\"4399\" data-end=\"4469\">Types of Flow Meters Commonly Used in Oil, Gas, and Chemical Plants<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<div class=\"table-responsive\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4471\" data-end=\"5167\">\n<thead data-start=\"4471\" data-end=\"4523\">\n<tr data-start=\"4471\" data-end=\"4523\">\n<th data-start=\"4471\" data-end=\"4489\" data-col-size=\"sm\">Flow Meter Type<\/th>\n<th data-start=\"4489\" data-end=\"4508\" data-col-size=\"sm\">Best Application<\/th>\n<th data-start=\"4508\" data-end=\"4515\" data-col-size=\"sm\">\u041f\u043b\u044e\u0441\u044b<\/th>\n<th data-start=\"4515\" data-end=\"4523\" data-col-size=\"md\">Cons<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4575\" data-end=\"5167\">\n<tr data-start=\"4575\" data-end=\"4715\">\n<td data-start=\"4575\" data-end=\"4608\" data-col-size=\"sm\"><strong data-start=\"4577\" data-end=\"4607\">Differential Pressure (DP)<\/strong><\/td>\n<td data-start=\"4608\" data-end=\"4637\" data-col-size=\"sm\">Steam, water, hydrocarbons<\/td>\n<td data-start=\"4637\" data-end=\"4674\" data-col-size=\"sm\">Simple, reliable, widely available<\/td>\n<td data-start=\"4674\" data-end=\"4715\" data-col-size=\"md\">Pressure drop, requires straight pipe<\/td>\n<\/tr>\n<tr data-start=\"4716\" data-end=\"4823\">\n<td data-start=\"4716\" data-end=\"4731\" data-col-size=\"sm\"><strong data-start=\"4718\" data-end=\"4730\">\u041a\u043e\u0440\u0438\u043e\u043b\u0438\u0441<\/strong><\/td>\n<td data-start=\"4731\" data-end=\"4760\" data-col-size=\"sm\">Mass flow, chemical dosing<\/td>\n<td data-start=\"4760\" data-end=\"4801\" data-col-size=\"sm\">High accuracy, direct mass measurement<\/td>\n<td data-start=\"4801\" data-end=\"4823\" data-col-size=\"md\">\u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c, \u0442\u044f\u0436\u0435\u043b\u044b\u0435<\/td>\n<\/tr>\n<tr data-start=\"4824\" data-end=\"4942\">\n<td data-start=\"4824\" data-end=\"4846\" data-col-size=\"sm\"><strong data-start=\"4826\" data-end=\"4845\">\u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439<\/strong><\/td>\n<td data-start=\"4846\" data-end=\"4867\" data-col-size=\"sm\">\u041f\u0440\u043e\u0432\u043e\u0434\u044f\u0449\u0438\u0435 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438<\/td>\n<td data-start=\"4867\" data-end=\"4902\" data-col-size=\"sm\">\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0434\u0432\u0438\u0436\u0443\u0449\u0438\u0445\u0441\u044f \u0447\u0430\u0441\u0442\u0435\u0439, \u043d\u0438\u0437\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<\/td>\n<td data-start=\"4902\" data-end=\"4942\" data-col-size=\"md\">Cannot measure non-conductive fluids<\/td>\n<\/tr>\n<tr data-start=\"4943\" data-end=\"5053\">\n<td data-start=\"4943\" data-end=\"4960\" data-col-size=\"sm\"><strong data-start=\"4945\" data-end=\"4959\">\u0423\u043b\u044c\u0442\u0440\u0430\u0437\u0432\u0443\u043a\u043e\u0432\u043e\u0439<\/strong><\/td>\n<td data-start=\"4960\" data-end=\"4988\" data-col-size=\"sm\">\u0411\u043e\u043b\u044c\u0448\u0438\u0435 \u0442\u0440\u0443\u0431\u044b, \u043d\u0435\u0438\u043d\u0432\u0430\u0437\u0438\u0432\u043d\u044b\u0435<\/td>\n<td data-start=\"4988\" data-end=\"5019\" data-col-size=\"sm\">Non-intrusive, easy retrofit<\/td>\n<td data-start=\"5019\" data-end=\"5053\" data-col-size=\"md\">Sensitive to bubbles or solids<\/td>\n<\/tr>\n<tr data-start=\"5054\" data-end=\"5167\">\n<td data-start=\"5054\" data-end=\"5068\" data-col-size=\"sm\"><strong data-start=\"5056\" data-end=\"5067\">Turbine<\/strong><\/td>\n<td data-start=\"5068\" data-end=\"5090\" data-col-size=\"sm\">Clean liquids, fuel<\/td>\n<td data-start=\"5090\" data-end=\"5122\" data-col-size=\"sm\">High accuracy, good linearity<\/td>\n<td data-start=\"5122\" data-end=\"5167\" data-col-size=\"md\">Not suitable for slurry or viscous fluids<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<\/div>\n\n<hr data-start=\"5169\" data-end=\"5172\" \/>\n\n<h2 data-start=\"5174\" data-end=\"5204\">Installation Best Practices<\/h2>\n<ol data-start=\"5206\" data-end=\"5602\">\n \t<li data-start=\"5206\" data-end=\"5293\">\n<p data-start=\"5209\" data-end=\"5293\"><strong data-start=\"5209\" data-end=\"5232\">Correct orientation<\/strong>: Follow manufacturer guidelines (horizontal vs. vertical).<\/p>\n<\/li>\n \t<li data-start=\"5294\" data-end=\"5363\">\n<p data-start=\"5297\" data-end=\"5363\"><strong data-start=\"5297\" data-end=\"5317\">Avoid turbulence<\/strong>: Install with proper straight pipe lengths.<\/p>\n<\/li>\n \t<li data-start=\"5364\" data-end=\"5436\">\n<p data-start=\"5367\" data-end=\"5436\"><strong data-start=\"5367\" data-end=\"5398\">Impulse lines for DP meters<\/strong>: Ensure proper filling and venting.<\/p>\n<\/li>\n \t<li data-start=\"5437\" data-end=\"5524\">\n<p data-start=\"5440\" data-end=\"5524\"><strong data-start=\"5440\" data-end=\"5468\">Environmental protection<\/strong>: Use enclosures or insulation for extreme conditions.<\/p>\n<\/li>\n \t<li data-start=\"5525\" data-end=\"5602\">\n<p data-start=\"5528\" data-end=\"5602\"><strong data-start=\"5528\" data-end=\"5550\">Calibration access<\/strong>: Install in locations accessible for maintenance.<\/p>\n<\/li>\n<\/ol>\n\n<hr data-start=\"5604\" data-end=\"5607\" \/>\n\n<h2 data-start=\"5609\" data-end=\"5628\">Maintenance Tips<\/h2>\n<ul data-start=\"5630\" data-end=\"5892\">\n \t<li data-start=\"5630\" data-end=\"5701\">\n<p data-start=\"5632\" data-end=\"5701\">Schedule routine calibration (6\u201312 months depending on criticality)<\/p>\n<\/li>\n \t<li data-start=\"5702\" data-end=\"5757\">\n<p data-start=\"5704\" data-end=\"5757\">Inspect for deposits, corrosion, or mechanical wear<\/p>\n<\/li>\n \t<li data-start=\"5758\" data-end=\"5826\">\n<p data-start=\"5760\" data-end=\"5826\">Clean strainers and filters upstream to protect sensitive meters<\/p>\n<\/li>\n \t<li data-start=\"5827\" data-end=\"5892\">\n<p data-start=\"5829\" data-end=\"5892\">Monitor flow meter diagnostics for early warning of anomalies<\/p>\n<\/li>\n<\/ul>\n\n<hr data-start=\"5894\" data-end=\"5897\" \/>\n\n<h2 data-start=\"5899\" data-end=\"5912\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\n<p data-start=\"5914\" data-end=\"6367\">Selecting the right flow meter for oil, gas, or chemical plants is a multi-factor decision. By evaluating fluid properties, flow range, accuracy, environmental conditions, and communication needs, you ensure reliable measurement, process efficiency, and safety. Proper selection, installation, and maintenance help industrial plants achieve accurate flow monitoring, reduce operational costs, and maintain compliance with industry standards.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Flow Meter Selection Guide | Oil, Gas &amp; Chemical Plant Applications Accurate flow measurement is a critical component of industrial process control. In oil, gas, and chemical plants, flow meters are essential for monitoring liquids, gases, and slurries to ensure process efficiency, safety, and compliance with environmental standards. Selecting the right flow meter for your&#8230;<\/p>","protected":false},"author":1,"featured_media":30616,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[296],"tags":[390,378,389,380,375,391,388,384,392,382,376,385,369,381,379],"class_list":["post-30615","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-meter","tag-chemical-plant-instrumentation","tag-coriolis-flow-meter","tag-dp-flow-meter","tag-electromagnetic-flow-meter","tag-flow-meter","tag-flow-meter-calibration","tag-flow-meter-installation","tag-flow-meter-selection","tag-hazardous-area-flow-meter","tag-industrial-flow-measurement","tag-industrial-flow-meter","tag-oil-and-gas-flow-monitoring","tag-process-automation-instrumentation","tag-turbine-flow-meter","tag-ultrasonic-flow-meter"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants? - Instrava<\/title>\n<meta name=\"description\" content=\"Learn how to select the right flow meter for oil, gas, and chemical plants. Explore meter types, selection criteria, installation tips, and industrial applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrava.com\/ru\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants? - Instrava\" \/>\n<meta property=\"og:description\" content=\"Learn how to select the right flow meter for oil, gas, and chemical plants. Explore meter types, selection criteria, installation tips, and industrial applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrava.com\/ru\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/\" \/>\n<meta property=\"og:site_name\" content=\"Instrava\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-07T07:25:11+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-22T07:32:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/water-flow-meter.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Instrava\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"Instrava\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u043c\u0438\u043d\u0443\u0442\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/\"},\"author\":{\"name\":\"Instrava\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\"},\"headline\":\"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants?\",\"datePublished\":\"2026-01-07T07:25:11+00:00\",\"dateModified\":\"2026-01-22T07:32:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/\"},\"wordCount\":728,\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/water-flow-meter.webp\",\"keywords\":[\"chemical plant instrumentation\",\"Coriolis flow meter\",\"DP flow meter\",\"electromagnetic flow meter\",\"flow meter\",\"flow meter calibration\",\"flow meter installation\",\"flow meter selection\",\"hazardous area flow meter\",\"industrial flow measurement\",\"industrial flow meter\",\"oil and gas flow monitoring\",\"process automation instrumentation\",\"turbine flow meter\",\"ultrasonic flow meter\"],\"articleSection\":[\"Flow Meter\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/\",\"name\":\"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants? - Instrava\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/water-flow-meter.webp\",\"datePublished\":\"2026-01-07T07:25:11+00:00\",\"dateModified\":\"2026-01-22T07:32:33+00:00\",\"description\":\"Learn how to select the right flow meter for oil, gas, and chemical plants. Explore meter types, selection criteria, installation tips, and industrial applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/water-flow-meter.webp\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/water-flow-meter.webp\",\"width\":1200,\"height\":650,\"caption\":\"This image shows a water flow meter positioned in a large industrial plant, suitable for precise liquid flow measurement in industrial environments.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrava.com\\\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrava.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Flow Meter\",\"item\":\"https:\\\/\\\/instrava.com\\\/category\\\/flow-meter\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#website\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"name\":\"instrava.com\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrava.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#organization\",\"name\":\"instrava.com\",\"url\":\"https:\\\/\\\/instrava.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"contentUrl\":\"https:\\\/\\\/instrava.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/in-strava-Instruments-and-meters.png\",\"width\":288,\"height\":59,\"caption\":\"instrava.com\"},\"image\":{\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrava.com\\\/#\\\/schema\\\/person\\\/5a2cb70825977eb9d0591b5629aa11a6\",\"name\":\"Instrava\",\"sameAs\":[\"https:\\\/\\\/instrava.com\"],\"url\":\"https:\\\/\\\/instrava.com\\\/ru\\\/author\\\/matrinpolergmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants? - Instrava","description":"Learn how to select the right flow meter for oil, gas, and chemical plants. Explore meter types, selection criteria, installation tips, and industrial applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrava.com\/ru\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/","og_locale":"ru_RU","og_type":"article","og_title":"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants? - Instrava","og_description":"Learn how to select the right flow meter for oil, gas, and chemical plants. Explore meter types, selection criteria, installation tips, and industrial applications.","og_url":"https:\/\/instrava.com\/ru\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/","og_site_name":"Instrava","article_published_time":"2026-01-07T07:25:11+00:00","article_modified_time":"2026-01-22T07:32:33+00:00","og_image":[{"width":1200,"height":650,"url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/water-flow-meter.webp","type":"image\/webp"}],"author":"Instrava","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"Instrava","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"5 \u043c\u0438\u043d\u0443\u0442"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/#article","isPartOf":{"@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/"},"author":{"name":"Instrava","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6"},"headline":"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants?","datePublished":"2026-01-07T07:25:11+00:00","dateModified":"2026-01-22T07:32:33+00:00","mainEntityOfPage":{"@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/"},"wordCount":728,"publisher":{"@id":"https:\/\/instrava.com\/#organization"},"image":{"@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/water-flow-meter.webp","keywords":["chemical plant instrumentation","Coriolis flow meter","DP flow meter","electromagnetic flow meter","flow meter","flow meter calibration","flow meter installation","flow meter selection","hazardous area flow meter","industrial flow measurement","industrial flow meter","oil and gas flow monitoring","process automation instrumentation","turbine flow meter","ultrasonic flow meter"],"articleSection":["Flow Meter"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/","url":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/","name":"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants? - Instrava","isPartOf":{"@id":"https:\/\/instrava.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/#primaryimage"},"image":{"@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/#primaryimage"},"thumbnailUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/water-flow-meter.webp","datePublished":"2026-01-07T07:25:11+00:00","dateModified":"2026-01-22T07:32:33+00:00","description":"Learn how to select the right flow meter for oil, gas, and chemical plants. Explore meter types, selection criteria, installation tips, and industrial applications.","breadcrumb":{"@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/#primaryimage","url":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/water-flow-meter.webp","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2026\/01\/water-flow-meter.webp","width":1200,"height":650,"caption":"This image shows a water flow meter positioned in a large industrial plant, suitable for precise liquid flow measurement in industrial environments."},{"@type":"BreadcrumbList","@id":"https:\/\/instrava.com\/how-do-you-select-the-right-flow-meter-for-oil-gas-or-chemical-plants\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrava.com\/"},{"@type":"ListItem","position":2,"name":"Flow Meter","item":"https:\/\/instrava.com\/category\/flow-meter\/"},{"@type":"ListItem","position":3,"name":"How Do You Select the Right Flow Meter for Oil, Gas, or Chemical Plants?"}]},{"@type":"WebSite","@id":"https:\/\/instrava.com\/#website","url":"https:\/\/instrava.com\/","name":"instrava.com","description":"","publisher":{"@id":"https:\/\/instrava.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrava.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Organization","@id":"https:\/\/instrava.com\/#organization","name":"instrava.com","url":"https:\/\/instrava.com\/","logo":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","contentUrl":"https:\/\/instrava.com\/wp-content\/uploads\/2024\/03\/in-strava-Instruments-and-meters.png","width":288,"height":59,"caption":"instrava.com"},"image":{"@id":"https:\/\/instrava.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/instrava.com\/#\/schema\/person\/5a2cb70825977eb9d0591b5629aa11a6","name":"Instrava","sameAs":["https:\/\/instrava.com"],"url":"https:\/\/instrava.com\/ru\/author\/matrinpolergmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/posts\/30615","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/comments?post=30615"}],"version-history":[{"count":0,"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/posts\/30615\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/media\/30616"}],"wp:attachment":[{"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/media?parent=30615"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/categories?post=30615"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrava.com\/ru\/wp-json\/wp\/v2\/tags?post=30615"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}