Pengukur Aliran

V-Cone Flow Meter

High-Accuracy Differential Pressure Flow Measurement for Harsh Process Conditions

The V-Cone flow meter is an advanced differential pressure (DP) flow measurement device designed for accurate and repeatable measurement of liquids, gases, and steam under demanding process conditions. By placing a cone-shaped obstruction in the center of the pipe, the V-Cone creates a stable differential pressure that is less sensitive to upstream flow disturbances.

Instrava V-Cone flow meters are engineered for applications where space is limited, flow profiles are unstable, or traditional DP meters struggle to maintain accuracy. With no moving parts and strong resistance to erosion and vibration, the V-Cone meter delivers long-term reliability in high-pressure, high-temperature, and multiphase environments.

  Flow Meter Description  

V-Cone Flow Meter-Key Features 1

  • Minimal installation requirements
    Built-in flow conditioning reshapes velocity distribution, eliminating eddies and dead zones. Straight pipe requirements are greatly reduced: upstream 0–3D (up to 30D depending on application), downstream 0–1D.

  • Wide turndown ratio
    Typical turndown ratio of 10:1, with a maximum up to 50:1, enabling accurate measurement across wide flow ranges.

  • Low permanent pressure loss with stable signal
    For the same β ratio, pressure loss is only 1/3–1/5 of an orifice plate, while signal fluctuation is reduced to approximately 1/10, ensuring superior measurement stability.

  • Excellent wear resistance
    The streamlined V-cone geometry creates a localized vacuum effect on the cone surface, significantly reducing direct particle impingement and extending service life.

  • Self-cleaning, non-clogging design
    Full purging flow pattern prevents sediment deposition, particle accumulation, and media adhesion—ideal for dirty and particulate-laden fluids.

V-cone flow meter for industrial flow measurement
V-cone flow meter manufacturer for industrial applications

V-Cone Flow Meter-Key Features 2

  • Long-term measurement stability
    The β ratio remains stable over extended operation, ensuring consistent accuracy and repeatability throughout the product lifecycle.

  • High accuracy and repeatability
    Measurement accuracy up to ±0.5% F.S, with repeatability of ±0.1% F.S, suitable for demanding process control applications.

  • Wide β ratio selection
    The unique V-cone geometry allows a broad range of β values, enabling flexible design for various flow rates and operating conditions.

  • Multiple installation configurations
    Available in pipeline type, flanged tapping, wafer type, and insertion (plug-in) configurations to suit different installation requirements.

  • Broad nominal diameter coverage
    Nominal sizes from DN15 to DN2000 (1/2″–120″), with larger or customized sizes available upon request.

V-Cone Flow Meter-Key Features 3

  • High-temperature and high-pressure capability
    Designed for extreme conditions with maximum working temperature up to 700 °C and maximum pressure up to 42 MPa.

  • Suitable for dirty and abrasive media
    Proven performance in challenging media such as coke-oven gas, blast furnace gas, feedstock oil, and residual oil.

  • Capable of multiphase measurement
    Reliable measurement of gas–liquid two-phase flows, including moisture-laden gas and fluids containing condensed water.

V-cone flow meter internal structure
V-cone flow meter working principle diagram

V-Cone Flow Meter Working Principle

The V-Cone flow meter is a differential pressure flow measurement device operating on the principle of energy conversion in a closed pipeline. As fluid flows through the pipe, its velocity and static pressure change according to Bernoulli’s principle.

When the medium approaches the upstream section of the V-cone, the static pressure is P₁. As the flow passes around the cone, the effective flow area is reduced, causing the fluid velocity to increase and the static pressure to decrease to P₂ at the throttling region. The pressure difference ΔP = P₁ − P₂ is generated.

This differential pressure is transmitted to a differential pressure transmitter through upstream and downstream pressure tapping ports. Because the differential pressure is proportional to the square of the flow velocity, the actual flow rate can be accurately calculated from the measured ΔP value.

As the flow rate increases or decreases, the differential pressure changes correspondingly, enabling continuous, stable, and repeatable flow measurement for liquids, gases, steam, and multiphase media.

  Flow Meter Parameter  

ParameterSpesifikasi
ModelVCF 121
Accuracy Class0.5
Long-term Stability±0.1% F.S / year
Pengulangan±0.1%
Minimum Flow Velocity≥ 0.1 m/s
Turndown RatioTypical 15:1; Maximum 50:1
Reynolds Number Range8 × 10³ ~ 5 × 10⁶
Operating Pressure≤ 16 MPa (up to 42 MPa maximum)
Suhu Pengoperasian-160 °C ~ 700 °C
Nominal DiameterDN15 ~ DN2000 (1/2″ ~ 120″)
Ambient Temperature≤ 80 °C
Kelembaban Relatif5% ~ 85%
Output Signal4 ~ 20 mA
Catu Daya24 V DC
DP Transmitter Supply Voltage24 V DC
DP Transmitter Output Current4 ~ 20 mA
Intelligent Flow Totalizer Voltage220 V AC
Intelligent Flow Totalizer Output4 ~ 20 mA
DP Transmitter CommunicationHART / BRAIN
Flow Computation Indicator CommunicationRS232 / RS485
Installation TypesFlanged type, welded type, clamped type, insertion type

Applicable Conditions

  • Nominal diameter: DN15 ~ DN2000

  • Flow velocity: ≥ 0.1 m/s

  • Working pressure: -0.1 MPa ~ 42 MPa

  • Working temperature: -160 °C ~ 700 °C

  • Ambient temperature: ≤ 85 °C

In addition to standard gas, liquid, and steam measurement, the V-Cone flow meter is suitable for challenging media, including high-dust gases, fluids with high suspended solids, high-viscosity media, strongly corrosive fluids, crystallizing media, and supersaturated process conditions.

  Instrava OEM / ODM

Layanan Kustomisasi & OEM

Instrava is a partner focused on providing equipment, solutions, and services for industrial measurement and control instruments used in safety-critical and process control applications. We are committed to providing reliable and long-lasting solutions based on trust, communication, and collaboration, helping customers improve process efficiency and measurement accuracy.

As a trusted long-term partner for customers and OEM partners in China, Instrava provides professional OEM and customization services for venturi flow meters and industrial flow measurement solutions.

Industrial instrument manufacturer production workshop showing large-scale manufacturing of level gauges and process instruments

  Rekomendasi Produk Terkait  

Yes. V-Cone flow meters are designed with robust construction and no moving parts, allowing stable operation under high-pressure conditions. With appropriate material and pressure rating selection, they can be used in systems up to 42 MPa.

The centrally mounted V-cone acts as an internal flow conditioner, reshaping velocity distribution and minimizing the influence of swirl and turbulence. This allows accurate measurement even when upstream flow is highly disturbed.

No. One key advantage of the V-Cone flow meter is its minimal straight pipe requirement. In many applications, it requires 0–3D upstream and 0–1D downstream, making it ideal for space-limited installations.

Yes. V-Cone flow meters are widely used in saturated and superheated steam applications. Their ability to withstand high temperature and pressure, combined with stable differential pressure signals, makes them suitable for power and boiler systems.

Yes. V-Cone flow meters perform well in gas–liquid two-phase flow conditions, including wet gas and fluids containing condensed water. The self-cleaning cone design helps maintain measurement stability in multiphase environments.

The streamlined cone geometry creates a purging flow pattern that prevents particle buildup and clogging. This makes V-Cone meters suitable for high-dust gases, fluids with suspended solids, and viscous or fouling media.

Mengapa Memilih Instrava

Dengan memilih Instrava, Anda mendapatkan mitra dengan pemahaman mendalam tentang aplikasi industri dan keahlian untuk memenuhi tantangan operasional saat ini.
Peran kami lebih dari sekadar produk-kami mendukung kesuksesan Anda melalui solusi yang dapat diandalkan dan komitmen jangka panjang.

Inovasi Berbasis Rekayasa

Inovasi di Instrava dipandu oleh kebutuhan industri yang nyata. Kami terus menyempurnakan teknologi kami untuk menjawab tantangan operasional yang terus berkembang, memastikan kinerja yang praktis dan andal di lingkungan yang penuh tuntutan.

Kustomisasi Khusus Aplikasi

Kami menyediakan kustomisasi tingkat teknik agar sesuai dengan kondisi proses tertentu. Dari rentang pengukuran dan bahan hingga sinyal keluaran dan opsi pemasangan, solusi kami dikonfigurasikan agar sesuai dengan aplikasi nyata.

Kualitas dan Keandalan yang Terbukti

Kualitas dan keandalan merupakan hal yang mendasar bagi setiap produk Instrava. Diproduksi di bawah kontrol kualitas yang ketat dan diuji secara menyeluruh, instrumen kami memberikan kinerja yang akurat, stabil, dan jangka panjang.

Kemampuan Global dengan Dukungan Lokal

Instrava menggabungkan keahlian teknik global dengan dukungan lokal yang responsif, memastikan mitra kami mendapatkan keuntungan dari teknologi yang selaras secara internasional dan layanan regional yang tepat waktu.

Portofolio Produk yang Komprehensif

Portofolio instrumen pengukuran dan kontrol kami yang luas memungkinkan kami untuk memenuhi berbagai kebutuhan industri, memberikan solusi terintegrasi dari satu sumber yang dapat diandalkan.

Dukungan Rekayasa Berorientasi Mitra

Kami bekerja sama dengan mitra kami mulai dari konsultasi teknis hingga dukungan purna jual. Fokus kami adalah memberikan solusi yang menciptakan nilai yang langgeng dan mendukung kesuksesan operasional jangka panjang.

Tekanan Termal vs Vortex vs Diferensial: Cara Memilih Teknologi Pengukuran Aliran yang Tepat

  • Oleh Instrava
  • 25 Februari 2026

Memilih pengukur aliran jarang sekali hanya tentang akurasi. Dalam aplikasi industri, tantangan yang sebenarnya meliputi: Laju aliran variabel Tekanan...

  • 43Min Baca

Pengukur Aliran Roda Gigi Oval: Mengapa Masih Mendominasi Pengukuran Aliran Viskositas Tinggi dalam Otomasi Modern

  • Oleh Instrava
  • 28 Jan 2026

Kegigihan Pengukur Aliran Roda Gigi Oval yang Tenang Di era di mana sensor pintar, kembar digital, dan instrumentasi berbasis AI mendominasi...

  • 2Min Baca

Pengukur Aliran Ultrasonik Portabel - Pengukuran Aliran Industri yang Akurat

  • Oleh Instrava
  • Jan 22, 2026

Pengukur Aliran Ultrasonik Portabel - Pengukuran Aliran Industri yang Akurat | Pengukur Aliran Ultrasonik Portabel Instrava Ikhtisar Pengukur aliran ultrasonik portabel ...

  • 40 Menit Baca
Beranda
Produk
Whatsapp