Pengukur Aliran V-Cone

High-Accuracy Differential Pressure Flow Measurement for Harsh Process Conditions

The V-Cone flow meter is an advanced differential pressure (DP) flow measurement device designed for accurate and repeatable measurement of liquids, gases, and steam under demanding process conditions. By placing a cone-shaped obstruction in the center of the pipe, the V-Cone creates a stable differential pressure that is less sensitive to upstream flow disturbances.

Instrava V-Cone flow meters are engineered for applications where space is limited, flow profiles are unstable, or traditional DP meters struggle to maintain accuracy. With no moving parts and strong resistance to erosion and vibration, the V-Cone meter delivers long-term reliability in high-pressure, high-temperature, and multiphase environments.

Deskripsi Pengukur Aliran  

V-Cone Flow Meter-Key Features 1

  • Minimal installation requirements
    Built-in flow conditioning reshapes velocity distribution, eliminating eddies and dead zones. Straight pipe requirements are greatly reduced: upstream 0–3D (up to 30D depending on application), downstream 0–1D.

  • Rasio penolakan yang lebar
    Typical turndown ratio of 10:1, with a maximum up to 50:1, enabling accurate measurement across wide flow ranges.

  • Low permanent pressure loss with stable signal
    For the same β ratio, pressure loss is only 1/3–1/5 of an orifice plate, while signal fluctuation is reduced to approximately 1/10, ensuring superior measurement stability.

  • Excellent wear resistance
    The streamlined V-cone geometry creates a localized vacuum effect on the cone surface, significantly reducing direct particle impingement and extending service life.

  • Self-cleaning, non-clogging design
    Full purging flow pattern prevents sediment deposition, particle accumulation, and media adhesion—ideal for dirty and particulate-laden fluids.

V-cone flow meter for industrial flow measurement
V-cone flow meter manufacturer for industrial applications

V-Cone Flow Meter-Key Features 2

  • Long-term measurement stability
    The β ratio remains stable over extended operation, ensuring consistent accuracy and repeatability throughout the product lifecycle.

  • Akurasi dan pengulangan yang tinggi
    Measurement accuracy up to ±0.5% F.S, with repeatability of ±0.1% F.S, suitable for demanding process control applications.

  • Wide β ratio selection
    The unique V-cone geometry allows a broad range of β values, enabling flexible design for various flow rates and operating conditions.

  • Multiple installation configurations
    Available in pipeline type, flanged tapping, wafer type, and insertion (plug-in) configurations to suit different installation requirements.

  • Broad nominal diameter coverage
    Nominal sizes from DN15 to DN2000 (1/2″–120″), with larger or customized sizes available upon request.

V-Cone Flow Meter-Key Features 3

  • High-temperature and high-pressure capability
    Designed for extreme conditions with maximum working temperature up to 700 °C and maximum pressure up to 42 MPa.

  • Suitable for dirty and abrasive media
    Proven performance in challenging media such as coke-oven gas, blast furnace gas, feedstock oil, and residual oil.

  • Capable of multiphase measurement
    Reliable measurement of gas–liquid two-phase flows, including moisture-laden gas and fluids containing condensed water.

V-cone flow meter internal structure
V-cone flow meter working principle diagram

V-Cone Flow Meter Working Principle

The V-Cone flow meter is a differential pressure flow measurement device operating on the principle of energy conversion in a closed pipeline. As fluid flows through the pipe, its velocity and static pressure change according to Bernoulli’s principle.

When the medium approaches the upstream section of the V-cone, the static pressure is P₁. As the flow passes around the cone, the effective flow area is reduced, causing the fluid velocity to increase and the static pressure to decrease to P₂ at the throttling region. The pressure difference ΔP = P₁ − P₂ is generated.

This differential pressure is transmitted to a differential pressure transmitter through upstream and downstream pressure tapping ports. Because the differential pressure is proportional to the square of the flow velocity, the actual flow rate can be accurately calculated from the measured ΔP value.

As the flow rate increases or decreases, the differential pressure changes correspondingly, enabling continuous, stable, and repeatable flow measurement for liquids, gases, steam, and multiphase media.

Parameter Pengukur Aliran  

ParameterSpesifikasi
ModelVCF 121
Kelas Akurasi0.5
Stabilitas Jangka Panjang±0.1% F.S / year
Pengulangan±0.1%
Kecepatan Aliran Minimum≥ 0.1 m/s
Turndown RatioTypical 15:1; Maximum 50:1
Rentang Angka Reynolds8 × 10³ ~ 5 × 10⁶
Operating Pressure≤ 16 MPa (up to 42 MPa maximum)
Suhu Pengoperasian-160 °C ~ 700 °C
Diameter NominalDN15 ~ DN2000 (1/2″ ~ 120″)
Suhu Sekitar≤ 80 °C
Kelembaban Relatif5% ~ 85%
Sinyal Keluaran4 ~ 20 mA
Catu Daya24 V DC
DP Transmitter Supply Voltage24 V DC
DP Transmitter Output Current4 ~ 20 mA
Intelligent Flow Totalizer Voltage220 V AC
Intelligent Flow Totalizer Output4 ~ 20 mA
DP Transmitter CommunicationHART / BRAIN
Flow Computation Indicator CommunicationRS232 / RS485
Installation TypesFlanged type, welded type, clamped type, insertion type

Applicable Conditions

  • Nominal diameter: DN15 ~ DN2000

  • Flow velocity: ≥ 0.1 m/s

  • Working pressure: -0.1 MPa ~ 42 MPa

  • Working temperature: -160 °C ~ 700 °C

  • Suhu lingkungan: ≤ 85 °C

In addition to standard gas, liquid, and steam measurement, the V-Cone flow meter is suitable for challenging media, including high-dust gases, fluids with high suspended solids, high-viscosity media, strongly corrosive fluids, crystallizing media, and supersaturated process conditions.

Instrava OEM / ODM

Instrumen yang Dapat Diandalkan. Solusi yang Sesuai dengan Aplikasi Anda.

Instrava berfokus untuk memberikan solusi industri yang andal melalui produk yang dipilih dengan cermat, pengoptimalan berbasis aplikasi, dan penyesuaian yang fleksibel. Kami memilih instrumen yang telah terbukti dari produsen tepercaya untuk memastikan kualitas yang konsisten, mengoptimalkan solusi berdasarkan kondisi kerja nyata untuk memecahkan tantangan praktis, dan menyediakan konfigurasi yang disesuaikan untuk memenuhi kebutuhan aplikasi tertentu.

Dengan menggabungkan keahlian pemilihan dengan pemahaman aplikasi, Instrava membantu pelanggan mengurangi risiko, meningkatkan efisiensi, dan mencapai hasil yang dapat diandalkan dalam lingkungan industri yang kompleks.

Bengkel produksi produsen instrumen industri yang menunjukkan pembuatan pengukur level dan instrumen proses berskala besar

Rekomendasi Produk Terkait  

Yes. V-Cone flow meters are designed with robust construction and no moving parts, allowing stable operation under high-pressure conditions. With appropriate material and pressure rating selection, they can be used in systems up to 42 MPa.

The centrally mounted V-cone acts as an internal flow conditioner, reshaping velocity distribution and minimizing the influence of swirl and turbulence. This allows accurate measurement even when upstream flow is highly disturbed.

No. One key advantage of the V-Cone flow meter is its minimal straight pipe requirement. In many applications, it requires 0–3D upstream and 0–1D downstream, making it ideal for space-limited installations.

Yes. V-Cone flow meters are widely used in saturated and superheated steam applications. Their ability to withstand high temperature and pressure, combined with stable differential pressure signals, makes them suitable for power and boiler systems.

Yes. V-Cone flow meters perform well in gas–liquid two-phase flow conditions, including wet gas and fluids containing condensed water. The self-cleaning cone design helps maintain measurement stability in multiphase environments.

The streamlined cone geometry creates a purging flow pattern that prevents particle buildup and clogging. This makes V-Cone meters suitable for high-dust gases, fluids with suspended solids, and viscous or fouling media.

Mengapa Memilih Instrava

Dibangun di atas Konsistensi, Bukan Klaim

Berfokus pada Aplikasi Industri

Kami mengkhususkan diri dalam analisis dan deteksi industri, dengan pemahaman yang jelas tentang lingkungan dan persyaratan operasi dunia nyata.

Kriteria Pemilihan Produk yang Ketat

Setiap instrumen dievaluasi berdasarkan performa, stabilitas, dan kesesuaian aplikasi-bukan hanya spesifikasi atau harga.

Konsistensi Pasokan & Kualitas yang Dapat Diandalkan

Kami bekerja sama dengan produsen tepercaya untuk memastikan pasokan yang stabil, kualitas yang konsisten, dan pengiriman yang dapat diandalkan.

Dukungan Praktis dan Berbasis Pengalaman

Rekomendasi kami didasarkan pada pemahaman aplikasi, membantu pelanggan menghindari masalah umum dan mencapai hasil yang dapat diandalkan.

Instrava dibuat untuk mengurangi ketidakpastian-sehingga setiap keputusan yang Anda buat menjadi lebih jelas, aman, dan dapat diandalkan.

Adegan pengukuran industri yang menunjukkan seorang pekerja menggunakan alat ukur presisi untuk mengukur dan menandai material di meja kerja, menunjukkan aplikasi praktis alat ukur dalam manufaktur dan pemrosesan.

Instrumentasi Bergeser Menuju Platform Orkestrasi: Apa Artinya bagi Sistem Industri

  • Oleh Instrava
  • 3 April 2026

Pendahuluan Instrumentasi industri sedang mengalami transformasi mendasar. Secara tradisional, instrumen seperti sensor, pemancar, dan penganalisis dioperasikan sebagai perangkat independen...

  • 2Min Baca

Apa yang dimaksud dengan “Instrumen sebagai Layanan” dalam Otomasi Industri?

  • Oleh Instrava
  • 3 April 2026

Instrumentasi industri sedang mengalami transformasi mendasar. Secara tradisional, instrumen biasanya digunakan sebagai perangkat keras yang berdiri sendiri-dipasang, dikalibrasi, dan dipelihara untuk...

  • 1Min Baca

Tekanan Termal vs Vortex vs Diferensial: Cara Memilih Teknologi Pengukuran Aliran yang Tepat

  • Oleh Instrava
  • 25 Februari 2026

Memilih pengukur aliran jarang sekali hanya tentang akurasi. Dalam aplikasi industri, tantangan yang sebenarnya meliputi: Laju aliran variabel Tekanan...

  • 1Min Baca
Beranda
Produk
Whatsapp
Kontak