V-Cone Flow Meter

High-Accuracy Differential Pressure Flow Measurement for Harsh Process Conditions

The V-Cone flow meter is an advanced differential pressure (DP) flow measurement device designed for accurate and repeatable measurement of liquids, gases, and steam under demanding process conditions. By placing a cone-shaped obstruction in the center of the pipe, the V-Cone creates a stable differential pressure that is less sensitive to upstream flow disturbances.

Instrava V-Cone flow meters are engineered for applications where space is limited, flow profiles are unstable, or traditional DP meters struggle to maintain accuracy. With no moving parts and strong resistance to erosion and vibration, the V-Cone meter delivers long-term reliability in high-pressure, high-temperature, and multiphase environments.

คำอธิบายเครื่องวัดอัตราการไหล  

V-Cone Flow Meter-Key Features 1

  • Minimal installation requirements
    Built-in flow conditioning reshapes velocity distribution, eliminating eddies and dead zones. Straight pipe requirements are greatly reduced: upstream 0–3D (up to 30D depending on application), downstream 0–1D.

  • อัตราส่วนการกลับตัวที่กว้าง
    Typical turndown ratio of 10:1, with a maximum up to 50:1, enabling accurate measurement across wide flow ranges.

  • Low permanent pressure loss with stable signal
    For the same β ratio, pressure loss is only 1/3–1/5 of an orifice plate, while signal fluctuation is reduced to approximately 1/10, ensuring superior measurement stability.

  • Excellent wear resistance
    The streamlined V-cone geometry creates a localized vacuum effect on the cone surface, significantly reducing direct particle impingement and extending service life.

  • Self-cleaning, non-clogging design
    Full purging flow pattern prevents sediment deposition, particle accumulation, and media adhesion—ideal for dirty and particulate-laden fluids.

V-cone flow meter for industrial flow measurement
V-cone flow meter manufacturer for industrial applications

V-Cone Flow Meter-Key Features 2

  • Long-term measurement stability
    The β ratio remains stable over extended operation, ensuring consistent accuracy and repeatability throughout the product lifecycle.

  • High accuracy and repeatability
    Measurement accuracy up to ±0.5% F.S, with repeatability of ±0.1% F.S, suitable for demanding process control applications.

  • Wide β ratio selection
    The unique V-cone geometry allows a broad range of β values, enabling flexible design for various flow rates and operating conditions.

  • Multiple installation configurations
    Available in pipeline type, flanged tapping, wafer type, and insertion (plug-in) configurations to suit different installation requirements.

  • Broad nominal diameter coverage
    Nominal sizes from DN15 to DN2000 (1/2″–120″), with larger or customized sizes available upon request.

V-Cone Flow Meter-Key Features 3

  • High-temperature and high-pressure capability
    Designed for extreme conditions with maximum working temperature up to 700 °C and maximum pressure up to 42 MPa.

  • Suitable for dirty and abrasive media
    Proven performance in challenging media such as coke-oven gas, blast furnace gas, feedstock oil, and residual oil.

  • Capable of multiphase measurement
    Reliable measurement of gas–liquid two-phase flows, including moisture-laden gas and fluids containing condensed water.

V-cone flow meter internal structure
V-cone flow meter working principle diagram

V-Cone Flow Meter Working Principle

The V-Cone flow meter is a differential pressure flow measurement device operating on the principle of energy conversion in a closed pipeline. As fluid flows through the pipe, its velocity and static pressure change according to Bernoulli’s principle.

When the medium approaches the upstream section of the V-cone, the static pressure is P₁. As the flow passes around the cone, the effective flow area is reduced, causing the fluid velocity to increase and the static pressure to decrease to P₂ at the throttling region. The pressure difference ΔP = P₁ − P₂ is generated.

This differential pressure is transmitted to a differential pressure transmitter through upstream and downstream pressure tapping ports. Because the differential pressure is proportional to the square of the flow velocity, the actual flow rate can be accurately calculated from the measured ΔP value.

As the flow rate increases or decreases, the differential pressure changes correspondingly, enabling continuous, stable, and repeatable flow measurement for liquids, gases, steam, and multiphase media.

พารามิเตอร์ของเครื่องวัดอัตราการไหล  

พารามิเตอร์ข้อกำหนด
แบบจำลองVCF 121
Accuracy Class0.5
ความมั่นคงระยะยาว±0.1% F.S / year
ความสามารถในการทำซ้ำ±0.1%
Minimum Flow Velocity≥ 0.1 m/s
Turndown RatioTypical 15:1; Maximum 50:1
Reynolds Number Range8 × 10³ ~ 5 × 10⁶
ความดันในการทำงาน≤ 16 MPa (up to 42 MPa maximum)
อุณหภูมิการทำงาน-160 °C ~ 700 °C
เส้นผ่านศูนย์กลางตามชื่อDN15 ~ DN2000 (1/2″ ~ 120″)
อุณหภูมิแวดล้อม≤ 80 °C
ความชื้นสัมพัทธ์5% ~ 85%
สัญญาณขาออก4 ~ 20 mA
แหล่งจ่ายไฟ24 V DC
DP Transmitter Supply Voltage24 V DC
DP Transmitter Output Current4 ~ 20 mA
Intelligent Flow Totalizer Voltage220 V AC
Intelligent Flow Totalizer Output4 ~ 20 mA
DP Transmitter CommunicationHART / BRAIN
Flow Computation Indicator CommunicationRS232 / RS485
Installation TypesFlanged type, welded type, clamped type, insertion type

Applicable Conditions

  • Nominal diameter: DN15 ~ DN2000

  • Flow velocity: ≥ 0.1 m/s

  • Working pressure: -0.1 MPa ~ 42 MPa

  • Working temperature: -160 °C ~ 700 °C

  • อุณหภูมิแวดล้อม: ≤ 85 °C

In addition to standard gas, liquid, and steam measurement, the V-Cone flow meter is suitable for challenging media, including high-dust gases, fluids with high suspended solids, high-viscosity media, strongly corrosive fluids, crystallizing media, and supersaturated process conditions.

อินสตราวา OEM/ODM

เครื่องมือที่เชื่อถือได้. โซลูชันที่เหมาะกับงานของคุณ.

Instrava มุ่งเน้นในการนำเสนอโซลูชันอุตสาหกรรมที่เชื่อถือได้ ผ่านผลิตภัณฑ์ที่คัดสรรมาอย่างพิถีพิถัน การปรับแต่งให้เหมาะสมกับการใช้งาน และการปรับแต่งที่ยืดหยุ่น เราเลือกเครื่องมือที่ผ่านการพิสูจน์แล้วจากผู้ผลิตที่เชื่อถือได้ เพื่อให้มั่นใจในคุณภาพที่สม่ำเสมอ ปรับโซลูชันให้เหมาะสมตามสภาพการทำงานจริงเพื่อแก้ไขปัญหาที่เกิดขึ้นจริง และให้การกำหนดค่าที่ปรับแต่งได้เพื่อตอบสนองความต้องการเฉพาะของการใช้งาน.

ด้วยการผสานความเชี่ยวชาญในการคัดเลือกเข้ากับความเข้าใจในการประยุกต์ใช้งาน Instrava ช่วยให้ลูกค้าลดความเสี่ยง เพิ่มประสิทธิภาพ และบรรลุผลลัพธ์ที่เชื่อถือได้ในสภาพแวดล้อมอุตสาหกรรมที่ซับซ้อน.

โรงงานผลิตเครื่องมืออุตสาหกรรม แสดงการผลิตขนาดใหญ่ของมาตรวัดระดับและเครื่องมือกระบวนการ

คำแนะนำสินค้าที่เกี่ยวข้อง  

Yes. V-Cone flow meters are designed with robust construction and no moving parts, allowing stable operation under high-pressure conditions. With appropriate material and pressure rating selection, they can be used in systems up to 42 MPa.

The centrally mounted V-cone acts as an internal flow conditioner, reshaping velocity distribution and minimizing the influence of swirl and turbulence. This allows accurate measurement even when upstream flow is highly disturbed.

No. One key advantage of the V-Cone flow meter is its minimal straight pipe requirement. In many applications, it requires 0–3D upstream and 0–1D downstream, making it ideal for space-limited installations.

Yes. V-Cone flow meters are widely used in saturated and superheated steam applications. Their ability to withstand high temperature and pressure, combined with stable differential pressure signals, makes them suitable for power and boiler systems.

Yes. V-Cone flow meters perform well in gas–liquid two-phase flow conditions, including wet gas and fluids containing condensed water. The self-cleaning cone design helps maintain measurement stability in multiphase environments.

The streamlined cone geometry creates a purging flow pattern that prevents particle buildup and clogging. This makes V-Cone meters suitable for high-dust gases, fluids with suspended solids, and viscous or fouling media.

ทำไมต้องเลือก Instrava

สร้างบนความสม่ำเสมอ ไม่ใช่คำกล่าวอ้าง

มุ่งเน้นการใช้งานในอุตสาหกรรม

เราเชี่ยวชาญด้านการวิเคราะห์และตรวจจับในอุตสาหกรรม โดยมีความเข้าใจอย่างชัดเจนเกี่ยวกับสภาพแวดล้อมการทำงานจริงและความต้องการต่างๆ.

เกณฑ์การคัดเลือกผลิตภัณฑ์อย่างเข้มงวด

ทุกเครื่องมือได้รับการประเมินตามประสิทธิภาพ, ความเสถียร, และความเหมาะสมในการนำไปใช้—ไม่ใช่เพียงแค่ข้อมูลจำเพาะหรือราคา.

การจัดหาที่เชื่อถือได้และความสม่ำเสมอของคุณภาพ

เราทำงานร่วมกับผู้ผลิตที่เชื่อถือได้เพื่อให้แน่ใจว่ามีปริมาณการจัดหาที่เสถียร คุณภาพที่สม่ำเสมอ และการจัดส่งที่น่าเชื่อถือ.

การสนับสนุนที่ปฏิบัติได้จริงและอิงจากประสบการณ์

คำแนะนำของเราได้รับการสนับสนุนจากความเข้าใจในการใช้งานจริง ช่วยให้ลูกค้าหลีกเลี่ยงปัญหาทั่วไปและบรรลุผลลัพธ์ที่เชื่อถือได้.

Instrava ถูกสร้างขึ้นเพื่อลดความไม่แน่นอน—เพื่อให้ทุกการตัดสินใจของคุณชัดเจน ปลอดภัย และน่าเชื่อถือมากขึ้น.

ฉากการวัดอุตสาหกรรมที่แสดงคนงานกำลังใช้เครื่องมือวัดความแม่นยำในการวัดและทำเครื่องหมายวัสดุบนโต๊ะทำงาน ซึ่งแสดงให้เห็นถึงการประยุกต์ใช้เครื่องมือวัดในทางปฏิบัติในการผลิตและการแปรรูป.

เครื่องมือวัดกำลังเปลี่ยนไปสู่แพลตฟอร์มการประสานงาน: ความหมายสำหรับระบบอุตสาหกรรม

  • โดย อินสตราวา
  • เม.ย. 3, 2026

บทนำ เครื่องมือวัดอุตสาหกรรมกำลังเผชิญกับการเปลี่ยนแปลงพื้นฐาน. ตามแบบดั้งเดิม เครื่องมือวัดเช่นเซ็นเซอร์, ตัวส่งสัญญาณ, และตัววิเคราะห์ ทำงานเป็นอุปกรณ์อิสระ...

  • อ่าน 2 นาที

อะไรคือ “เครื่องมือเป็นบริการ” ในระบบอัตโนมัติอุตสาหกรรม?

  • โดย อินสตราวา
  • เม.ย. 3, 2026

เครื่องมือวัดอุตสาหกรรมกำลังเผชิญกับการเปลี่ยนแปลงพื้นฐานครั้งสำคัญ ในอดีต เครื่องมือวัดมักถูกนำไปใช้เป็นอุปกรณ์ฮาร์ดแวร์แบบสแตนด์อโลน—ติดตั้ง ปรับเทียบ และบำรุงรักษาเพื่อ...

  • 1 นาทีในการอ่าน

ความแตกต่างระหว่างความร้อน, วอร์เท็กซ์, และความดันต่าง: วิธีเลือกเทคโนโลยีการวัดปริมาณการไหลที่เหมาะสม

  • โดย อินสตราวา
  • ก.พ. 25, 2026

การเลือกเครื่องวัดอัตราการไหลไม่ได้ขึ้นอยู่กับค่าความแม่นยำเพียงอย่างเดียว ในอุตสาหกรรม ความท้าทายที่แท้จริงประกอบด้วย: อัตราการไหลที่เปลี่ยนแปลง ความดัน...

  • 1 นาทีในการอ่าน
หน้าแรก
ผลิตภัณฑ์
Whatsapp
ติดต่อ