Optical Analysis

Infrared Oil Analyzer & UV Liquid Analyzers

Advanced Infrared Oil Analysis for Water Quality Compliance

This infrared oil analyzer is designed for high-precision oil content detection in water, fully compliant with standard analytical methods. It supports full-spectrum scanning, three-wavenumber analysis, and non-dispersive infrared (NDIR) detection, enabling flexible measurement across different regulatory and industrial scenarios.

With adjustable extraction ratios and compatibility with multiple extraction solvents (such as carbon tetrachloride and tetrachloroethylene), the system ensures accurate detection for low to ultra-high concentration oil samples, widely used in:

  • Environmental water monitoring
  • Industrial wastewater discharge testing
  • Petrochemical and refinery analysis

  Optical Analysis Description  

Integrated Optical System & Intelligent UV Liquid Analysis

The instrument adopts an integrated optical structure with automatic wavelength calibration and zero adjustment, ensuring stable, drift-free operation.

Combined with UV liquid analyzer functionality, it enables:

  • Spectral scanning and absorbance analysis
  • Real-time display of spectra, wavenumber, and absorbance
  • Detection of extraction solvent purity
  • Dual-system analysis for enhanced reliability

Its high baseline stability and automatic zero correction eliminate measurement errors caused by environmental changes, ensuring long-term accuracy.

Ultraviolet UV liquid analyzer with integrated screen and printer for water testing
UV liquid analyzer spectrophotometer for COD and nitrate measurement in water

Flexible Operation, Data Management & Industrial Usability

Designed for industrial and laboratory efficiency, the analyzer offers:

  • Flexible extraction ratio settings for different concentration ranges
  • Wide cuvette compatibility for multi-application testing
  • Built-in data processing software for analysis and report generation
  • Embedded printer for instant reporting
  • Tablet expansion slot for extended control and data access
  • One-to-one technical support with lifetime maintenance service

The system delivers fast detection speeds:

  • Full spectrum scan: ~30 seconds
  • Non-dispersive IR method: ~2 seconds

This ensures high throughput in environmental monitoring and industrial quality control.

  Optical Analysis Parameter  

ParameterSpecification
Detection MethodsFull Spectrum Scan / Three-Wavenumber / NDIR
Detection Limit0.01 mg/L (40:1 ratio) / 0.04 mg/L (10:1 ratio)
Minimum Detection Concentration0.001 mg/L
Maximum Measurement Concentration640,000 mg/L
Measurement Range0–800 mg/L
Accuracy≤2%
RepeatabilityRSD ≤0.6% (30–40 mg/L, 11 tests)
LinearityR > 0.999
Wavenumber Range3400–2400 cm⁻¹
Wavenumber Accuracy±2 cm⁻¹
Wavenumber Repeatability±2 cm⁻¹
Absorbance Range0.00000–2.00000 AU
Baseline StabilityAuto zero correction, no drift
Scan SpeedFull spectrum: 30s / NDIR: 2s

  Instrava OEM/ODM  

Reliable Instruments. Solutions That Fit Your Application.

Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.

By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

symbolizing trust and the beginning of a long-term partnership

  Related Product Recommendations  

An infrared oil analyzer is used to measure oil and grease concentration in water, including industrial wastewater, surface water, and environmental samples. It is essential for regulatory compliance, pollution monitoring, and industrial discharge control.

It uses infrared absorption spectroscopy (NDIR or full-spectrum scanning) to detect oil content based on characteristic absorption peaks. The system can operate in:

  • Full spectrum mode (high accuracy)
  • Three-wavenumber method (standard compliance)
  • NDIR mode (fast detection)

This analyzer achieves an ultra-low detection limit of 0.001 mg/L, making it suitable for:

  • Trace oil detection in clean water
  • Environmental compliance monitoring
  • High-precision laboratory analysis

Yes. With a maximum measurement capacity of 640,000 mg/L, it can handle:

  • Heavy industrial wastewater
  • Oil-contaminated samples
  • Petrochemical process monitoring

The adjustable extraction ratio ensures accurate results across all concentration ranges

The system supports multiple extraction solvents, including:

  • Carbon tetrachloride (CCl₄)
  • Tetrachloroethylene (C₂Cl₄)

This flexibility allows compliance with different national and international testing standards.

By integrating infrared oil detection and UV liquid analysis, the system provides:

  • Comprehensive liquid analysis capability
  • Enhanced accuracy through dual-system verification
  • Broader application in water quality and chemical analysis

This makes it a versatile solution for environmental labs and industrial monitoring systems.

Thermal vs Vortex vs Differential Pressure: How to Choose the Right Flow Measurement Technology

  • By Instrava
  • Feb 25, 2026

Selecting a flow meter is rarely about accuracy alone. In industrial applications, the real challenges include: Variable flow rates Pressure...

  • 1Min Read

Oval Gear Flow Meter: Why It Still Dominates High-Viscosity Flow Measurement in Modern Automation

  • By Instrava
  • Jan 28, 2026

The Quiet Persistence of Oval Gear Flow Meters In an era where smart sensors, digital twins, and AI-driven instrumentation dominate...

  • 2Min Read

Portable Ultrasonic Flow Meters – Accurate Industrial Flow Measurement

  • By Instrava
  • Jan 22, 2026

Portable Ultrasonic Flow Meters – Accurate Industrial Flow Measurement | Instrava Portable Ultrasonic Flow Meters Overview Portable ultrasonic flow meters...

  • 1Min Read

Why Choose Instrava

Built on Consistency, Not Claims

Focused on Industrial Applications

We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.

Strict Product Selection Criteria

Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.

Reliable Supply & Quality Consistency

We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.

Practical, Experience-Based Support

Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.

Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.