Digital Twins: Bridging the Physical and Digital Worlds in Industry 4.0
Introduction: What Is a Digital Twin? Digital Twin technology has become one of the most important concepts in Industry 4.0,...
Home » Products » transformer » 1000 KVA Cast Resin Dry Type Transformer



Instrava Curated Transformer — Reliable Power Distribution Designed for Safety, Efficiency, and Long-Term Performance
At Instrava, we go beyond simply supplying electrical equipment. Through our Curated Transformer approach, we carefully evaluate and select proven transformer technologies from trusted manufacturers, ensuring reliability, safety, and consistent performance in critical power distribution applications.
The 1000 KVA Cast Resin Dry Type Transformer is engineered to deliver dependable medium-voltage to low-voltage power conversion in demanding industrial, commercial, and infrastructure environments. Featuring cast resin insulation technology, advanced temperature monitoring, low losses, and exceptional moisture resistance, this transformer provides a safer and more environmentally responsible alternative to traditional oil-filled transformers.
Designed for installations where fire safety, operational reliability, and reduced maintenance are priorities, this transformer is widely used in hospitals, schools, data centers, renewable energy facilities, manufacturing plants, commercial buildings, and other mission-critical applications.
Transformer Description
Why Choose a 1000 KVA Cast Resin Dry Type Transformer?
Unlike conventional oil-filled transformers, cast resin dry type transformers use solid epoxy resin insulation and contain no flammable insulating oil. This significantly reduces fire hazards, eliminates oil leakage risks, and minimizes environmental impact.
The encapsulated cast resin winding structure provides outstanding protection against moisture, dust, condensation, and contaminants. The transformer can operate safely even in environments with up to 100% humidity without requiring special dehumidification procedures.
Advanced magnetic core design and optimized winding technology help reduce no-load and load losses, improving overall system efficiency and lowering operating costs throughout the transformer’s service life.
Designed for demanding electrical networks, the transformer offers excellent mechanical strength and short-circuit resistance. It can operate continuously at 110% rated load with forced air cooling and withstand temporary overload conditions up to 150% rated load.
Precision core manufacturing and high-quality materials contribute to reduced operational noise levels, making the transformer ideal for noise-sensitive installations such as hospitals, schools, office buildings, and data centers.
Integrated BWDK series temperature monitoring devices continuously monitor winding temperatures for each phase, providing real-time temperature display, over-temperature alarms, and automatic trip protection to enhance operational safety.


Designed for Critical Power Applications
The 1000 KVA Cast Resin Dry Type Transformer is suitable for a wide range of industries and facilities where reliability and safety are essential.
Ensures stable power distribution while meeting stringent fire safety requirements and minimizing maintenance demands.
Provides reliable and uninterrupted power for hospitals, laboratories, and medical campuses where electrical reliability is critical.
Supports safe and efficient power distribution across schools, universities, research centers, and campus facilities.
Ideal for solar farms, wind energy systems, battery energy storage systems, and other clean energy applications requiring dependable voltage transformation.
Suitable for shopping centers, office complexes, hotels, airports, and public infrastructure projects.
Delivers reliable power distribution for factories, process plants, production lines, and heavy industrial operations.
Performs reliably in humid, dusty, corrosive, and other challenging operating environments where conventional transformers may face limitations.
Transformer Parameter
| Parameter | Specification |
|---|---|
| Product Name | 1000 KVA Cast Resin Dry Type Transformer |
| Transformer Type | Cast Resin Dry Type Transformer |
| Rated Power | 1000 KVA |
| Primary Voltage | 11 KV |
| Secondary Voltage | 0.33 KV |
| Vector Group | Dyn11, Yyno, or Customized |
| Capacity Range Available | 25 KVA – 20,000 KVA |
| Insulation System | Cast Resin Encapsulated Windings |
| Cooling Method | AN / AF |
| Overload Capability | 110% Rated Load (AF), Up to 150% Temporary Overload |
| Humidity Resistance | Up to 100% Relative Humidity |
| Short Circuit Resistance | High Mechanical Strength Design |
| Temperature Monitoring | BWDK Series Temperature Controller |
| Alarm Function | Over-Temperature Alarm |
| Protection Function | Automatic Over-Temperature Trip |
| Standards | ANSI, IEEE, CSA/CAN, DOE, IEC, GB |
| Certifications | UL, cUL, CSA, SGS, CE |
| Installation Environment | Indoor Applications |
| Fire Risk | Non-Flammable, Oil-Free Design |
| Rated Capacity(kVA) | Voltage Combined | Vector-group | No-load Loss(W) | 75ºC Load Loss(W) | No-load current(%) | Short-circuit Impendance(%) | ||
| High voltage(KV) | Tapping Ranges | Low voltage(KV) | ||||||
| 30 | 6 6.3 6.6 10 10.5 11 | ±5% ±2×2.5% | 0.4 | Dyn11 Yyn0 | 190 | 710 | 2.4 | 4 |
| 50 | 270 | 1000 | 2.4 | |||||
| 80 | 370 | 1380 | 1.8 | |||||
| 100 | 400 | 1570 | 1.8 | |||||
| 125 | 470 | 1850 | 1.6 | |||||
| 160 | 540 | 2130 | 1.6 | |||||
| 200 | 620 | 2530 | 1.4 | |||||
| 250 | 720 | 2760 | 1.4 | |||||
| 315 | 880 | 3470 | 1.2 | |||||
| 400 | 980 | 2990 | 1.2 | |||||
| 500 | 1160 | 4880 | 1.2 | |||||
| 630 | 1340 | 5880 | 1.0 | |||||
| 630 | 1300 | 5960 | 1.0 | 6 | ||||
| 800 | 1520 | 6960 | 1.0 | |||||
| 1000 | 1770 | 8130 | 1.0 | |||||
| 1250 | 2090 | 9690 | 1.0 | |||||
| 1600 | 2450 | 11730 | 1.0 | |||||
| 2000 | 6050 | 14450 | 0.8 | |||||
| 2500 | 3600 | 17170 | 0.8 | |||||
| 1600 | 2450 | 12960 | 1.0 | 8 | ||||
| 2000 | 3050 | 15960 | 0.8 | |||||
| 2500 | 3600 | 18890 | 0.8 | |||||
Instrava OEM/ODM
Reliable Instruments & Power Infrastructure. Solutions That Fit Your Application.
Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven measurement instruments and heavy-duty power transformers from trusted China manufacturers to ensure consistent quality. By thoroughly evaluating engineering topologies against real working conditions, we solve practical grid and process challenges, providing tailored configurations to meet specific application needs.
By combining selection expertise with deep application understanding, Instrava helps customers reduce operational risk, improve energy efficiency, and achieve dependable results across complex industrial and power distribution environments.

What is a cast resin dry type transformer?
A cast resin dry type transformer is a transformer that uses epoxy resin-encapsulated windings instead of liquid insulating oil. The resin insulation provides excellent electrical insulation, moisture resistance, fire safety, and environmental protection while reducing maintenance requirements compared to oil-filled transformers.
Why choose a 1000 KVA cast resin dry type transformer instead of an oil-filled transformer?
A 1000 KVA cast resin dry type transformer offers several advantages over oil-filled transformers, including improved fire safety, zero risk of oil leakage, lower environmental impact, reduced maintenance requirements, and better suitability for indoor installations such as hospitals, schools, data centers, and commercial buildings.
Where are 1000 KVA cast resin dry type transformers commonly used?
These transformers are commonly installed in:
They are particularly preferred where fire safety regulations are strict or where environmental protection is a priority.
Can a cast resin transformer operate in humid environments?
Yes. Cast resin transformers are specifically designed for excellent moisture resistance. The fully encapsulated winding structure allows reliable operation in environments with humidity levels approaching 100%, often without requiring additional dehumidification systems.
What protection systems are included in this transformer?
This transformer is equipped with a BWDK temperature monitoring system that continuously measures winding temperatures. The system provides:
How long does a cast resin dry type transformer typically last?
Under proper operating conditions and routine inspections, a high-quality cast resin dry type transformer can provide reliable service for 25 to 35 years or more. Factors such as loading conditions, ambient temperature, maintenance practices, and installation quality can influence actual service life.
Introduction: What Is a Digital Twin? Digital Twin technology has become one of the most important concepts in Industry 4.0,...
Built on Consistency, Not Claims
We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.
Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.
We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.
Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.
Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.