How to Choose the Right Liquid Analysis Solution for Industrial Applications
Selecting the right liquid analysis solution is critical for industrial process efficiency, product quality, and regulatory compliance. With multiple parameters...
Home » Products » Liquid Analysis » Optical Dissolved Oxygen Meter

In environmental monitoring, wastewater treatment optimization, and food or biochemical process control, dissolved oxygen is a key operational variable that directly affects biological stability, product quality, and regulatory compliance.
The Instrava Optical Dissolved Oxygen Meter adopts advanced fluorescence measurement technology, eliminating electrolyte consumption and membrane replacement while delivering 0.01 mg/L high resolution and ±0.3 mg/L accuracy.
Engineered as a handheld intelligent analyzer, it integrates:
✔ Smart result lock
✔ Intelligent alarm system
✔ Salinity & air pressure compensation
✔ IP67 waterproof protection
✔ Dual power supply
✔ Data storage & USB interface
✔ Optional GPS positioning
This is a professional field-grade optical DO analyzer designed for engineers who require precision, durability, and operational efficiency in real working environments.
Liquid Analysis Description
Optical Dissolved Oxygen Meter Application Scenarios
Continuous monitoring of dissolved oxygen concentration and saturation in rivers, lakes, and reservoirs. Suitable for regulatory compliance and mobile inspection tasks.
Optimizing aeration systems and biological treatment processes. Accurate DO control improves oxygen transfer efficiency and reduces energy waste.
Stable fluorescence-based measurement ensures reliable oxygen monitoring in controlled research environments.
Applicable for tap water systems and food processing where stable oxygen concentration impacts quality and safety.
Designed for both field deployment and laboratory verification, with rugged portability and intelligent operation support.


Optical Dissolved Oxygen Meter Engineering Advantages
No electrolyte consumption
No membrane replacement
No oxygen consumption during measurement
Reduced calibration frequency
Strong anti-interference capability
This significantly lowers long-term maintenance cost compared to traditional electrochemical DO meters.
DO Range: 0–20 mg/L
Saturation: 0–200%
Temperature: 0–50°C
Resolution: 0.01 mg/L; 0.01°C
Accuracy: ±0.3 mg/L (DO); ±0.5°C (Temperature)
Supports reliable decision-making in process control applications.
Automatic temperature compensation
Salinity compensation
Air pressure measurement (50–115 kPa)
One or two-point calibration
Ensures stable measurement across changing environmental and altitude conditions.
3.3-inch monochrome LCD display
Backlight display function
Chinese & English interface
Smart alarm system
Result smart lock
Data storage support
USB interface for data transfer
Optional GPS positioning system
Designed to support traceability and regulatory documentation.
IP67 waterproof and dustproof
Stainless steel optical electrode
Operating temperature: -10–60°C
Relative humidity: 10–85%RH (non-condensing)
Dual power supply (4×AA batteries)
Built for demanding outdoor inspection environments and continuous field monitoring.
Liquid Analysis Parameter
Display Screen: 3.3-inch monochrome LCD
Product Size: 7.87 × 3.98 × 1.42 inch
Product Weight: 420 g
Data Storage: Supported
Language: English / Chinese
Air Pressure Measurement: 50–115 kPa
Protection Grade: IP67
Power Supply: 4 × AA batteries
Operating Temperature: -10–60°C
Relative Humidity: 10–85%RH (No condensation)
Measuring Principle: Fluorescence method
Electrode Material: Stainless steel
DO Range: 0–20 mg/L
Saturation Range: 0–200%
Temperature Range: 0–50°C
Accuracy: ±0.3 mg/L (DO); ±0.5°C (Temp)
Resolution: 0.01 mg/L; 0.01°C
Calibration: One or two-point calibration
Temperature: -15–65°C
Relative Humidity: 5–85%RH (No condensation)
Instrava OEM/ODM
Reliable Instruments. Solutions That Fit Your Application.
Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.
By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

How does fluorescence technology improve dissolved oxygen measurement compared to traditional membrane probes?
Fluorescence probes measure DO without consuming oxygen, avoiding polarization and electrolyte maintenance. This provides stable, fast, and accurate readings even under variable flow or aeration conditions, reducing downtime and operational cost.
What makes this meter suitable for both field and laboratory water quality applications?
The meter combines IP67 waterproof protection, lightweight design (420g), long probe cable, and portable form factor with automatic temperature, salinity, and air pressure compensation, ensuring consistent performance indoors or on-site.
How reliable is this instrument under different environmental conditions?
It supports -10–60°C operation, 10–85% RH, altitude compensation, and has built-in data storage & backlight display. These features allow engineers to obtain accurate, reproducible readings in challenging environments.
Can this meter store and manage data for regulatory compliance or long-term monitoring?
Yes. It includes manual data logging, USB interface for export, and optional GPS tagging. Engineers can track dissolved oxygen trends over time, supporting compliance and process optimization.
What maintenance requirements should a procurement manager consider?
Unlike membrane DO meters, fluorescence sensors require minimal maintenance, no electrolyte filling, no membrane replacement, and calibration is infrequent, significantly lowering long-term operational cost.
How does compensation for salinity, temperature, and air pressure enhance measurement accuracy?
Dissolved oxygen readings are sensitive to these factors. This meter provides automatic temperature compensation, manual salinity adjustment, and air pressure compensation (50–115 kPa), ensuring precise, reliable results across diverse water bodies.
Built on Consistency, Not Claims
We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.
Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.
We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.
Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.
Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.

Selecting the right liquid analysis solution is critical for industrial process efficiency, product quality, and regulatory compliance. With multiple parameters...
Effective maintenance and calibration are critical for ensuring the accuracy, reliability, and longevity of liquid analysis instruments. In industrial environments,...
In modern industrial processes, monitoring multiple water quality parameters simultaneously is essential for operational efficiency, regulatory compliance, and process optimization....