Optical Dissolved Oxygen Meter

In environmental monitoring, wastewater treatment optimization, and food or biochemical process control, dissolved oxygen is a key operational variable that directly affects biological stability, product quality, and regulatory compliance.

The Instrava Optical Dissolved Oxygen Meter adopts advanced fluorescence measurement technology, eliminating electrolyte consumption and membrane replacement while delivering 0.01 mg/L high resolution and ±0.3 mg/L accuracy.

Engineered as a handheld intelligent analyzer, it integrates:

✔ Smart result lock
✔ Intelligent alarm system
✔ Salinity & air pressure compensation
✔ IP67 waterproof protection
✔ Dual power supply
✔ Data storage & USB interface
✔ Optional GPS positioning

This is a professional field-grade optical DO analyzer designed for engineers who require precision, durability, and operational efficiency in real working environments.

Liquid Analysis Description  

Optical Dissolved Oxygen Meter Application Scenarios

Environmental Protection & Surface Water Monitoring

Continuous monitoring of dissolved oxygen concentration and saturation in rivers, lakes, and reservoirs. Suitable for regulatory compliance and mobile inspection tasks.

Wastewater Treatment Plants

Optimizing aeration systems and biological treatment processes. Accurate DO control improves oxygen transfer efficiency and reduces energy waste.

Biochemical & Laboratory Applications

Stable fluorescence-based measurement ensures reliable oxygen monitoring in controlled research environments.

Food & Drinking Water Monitoring

Applicable for tap water systems and food processing where stable oxygen concentration impacts quality and safety.

Designed for both field deployment and laboratory verification, with rugged portability and intelligent operation support.

Front and back view of a dissolved oxygen meter showing the display screen, buttons, USB interface, and sensor interface layout, with device dimensions marked.
A portable dissolved oxygen meter with data storage and export functions, powered by USB and battery, featuring waterproofing, circuit protection, intelligent alarm, and auto power-off features.

Optical Dissolved Oxygen Meter Engineering Advantages

① Fluorescence Optical Measurement – Low Maintenance & High Stability

  • No electrolyte consumption

  • No membrane replacement

  • No oxygen consumption during measurement

  • Reduced calibration frequency

  • Strong anti-interference capability

This significantly lowers long-term maintenance cost compared to traditional electrochemical DO meters.

② High-Precision Multi-Parameter Detection

  • DO Range: 0–20 mg/L

  • Saturation: 0–200%

  • Temperature: 0–50°C

  • Resolution: 0.01 mg/L; 0.01°C

  • Accuracy: ±0.3 mg/L (DO); ±0.5°C (Temperature)

Supports reliable decision-making in process control applications.

③ Intelligent Compensation System

  • Automatic temperature compensation

  • Salinity compensation

  • Air pressure measurement (50–115 kPa)

  • One or two-point calibration

Ensures stable measurement across changing environmental and altitude conditions.

④ Smart Operation & Data Management

  • 3.3-inch monochrome LCD display

  • Backlight display function

  • Chinese & English interface

  • Smart alarm system

  • Result smart lock

  • Data storage support

  • USB interface for data transfer

  • Optional GPS positioning system

Designed to support traceability and regulatory documentation.

⑤ Industrial-Grade Protection & Field Durability

  • IP67 waterproof and dustproof

  • Stainless steel optical electrode

  • Operating temperature: -10–60°C

  • Relative humidity: 10–85%RH (non-condensing)

  • Dual power supply (4×AA batteries)

Built for demanding outdoor inspection environments and continuous field monitoring.

Liquid Analysis Parameter  

Optical Dissolved Oxygen Meter Technical Specifications

Instrument Specifications

  • Display Screen: 3.3-inch monochrome LCD

  • Product Size: 7.87 × 3.98 × 1.42 inch

  • Product Weight: 420 g

  • Data Storage: Supported

  • Language: English / Chinese

  • Air Pressure Measurement: 50–115 kPa

  • Protection Grade: IP67

  • Power Supply: 4 × AA batteries

  • Operating Temperature: -10–60°C

  • Relative Humidity: 10–85%RH (No condensation)


Sensor Specifications

  • Measuring Principle: Fluorescence method

  • Electrode Material: Stainless steel

  • DO Range: 0–20 mg/L

  • Saturation Range: 0–200%

  • Temperature Range: 0–50°C

  • Accuracy: ±0.3 mg/L (DO); ±0.5°C (Temp)

  • Resolution: 0.01 mg/L; 0.01°C

  • Calibration: One or two-point calibration


Storage & Transportation Conditions

  • Temperature: -15–65°C

  • Relative Humidity: 5–85%RH (No condensation)

Instrava OEM/ODM  

Reliable Instruments. Solutions That Fit Your Application.

Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.

By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

symbolizing trust and the beginning of a long-term partnership

Related Product Recommendations  

Fluorescence probes measure DO without consuming oxygen, avoiding polarization and electrolyte maintenance. This provides stable, fast, and accurate readings even under variable flow or aeration conditions, reducing downtime and operational cost.

The meter combines IP67 waterproof protection, lightweight design (420g), long probe cable, and portable form factor with automatic temperature, salinity, and air pressure compensation, ensuring consistent performance indoors or on-site.

It supports -10–60°C operation, 10–85% RH, altitude compensation, and has built-in data storage & backlight display. These features allow engineers to obtain accurate, reproducible readings in challenging environments.

Yes. It includes manual data logging, USB interface for export, and optional GPS tagging. Engineers can track dissolved oxygen trends over time, supporting compliance and process optimization.

Unlike membrane DO meters, fluorescence sensors require minimal maintenance, no electrolyte filling, no membrane replacement, and calibration is infrequent, significantly lowering long-term operational cost.

Dissolved oxygen readings are sensitive to these factors. This meter provides automatic temperature compensation, manual salinity adjustment, and air pressure compensation (50–115 kPa), ensuring precise, reliable results across diverse water bodies.

Why Choose Instrava

Built on Consistency, Not Claims

Focused on Industrial Applications

We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.

Strict Product Selection Criteria

Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.

Reliable Supply & Quality Consistency

We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.

Practical, Experience-Based Support

Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.

Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.

Industrial measurement scene showing a worker using a precision measuring instrument to measure and mark material on a workbench, demonstrating the practical application of measuring instruments in manufacturing and processing.

How to Choose the Right Liquid Analysis Solution for Industrial Applications

  • By Instrava
  • Mar 18, 2026

Selecting the right liquid analysis solution is critical for industrial process efficiency, product quality, and regulatory compliance. With multiple parameters...

  • 1Min Read

How to Optimize Maintenance and Calibration of Liquid Analysis Instruments

  • By Instrava
  • Mar 18, 2026

Effective maintenance and calibration are critical for ensuring the accuracy, reliability, and longevity of liquid analysis instruments. In industrial environments,...

  • 2Min Read

Multi-Parameter Water Quality Meter in Liquid Analysis Solutions: Integrated Monitoring for Industrial Efficiency

  • By Instrava
  • Mar 18, 2026

In modern industrial processes, monitoring multiple water quality parameters simultaneously is essential for operational efficiency, regulatory compliance, and process optimization....

  • 1Min Read
Home
Products
Whatsapp