Portable Water Digital EC Conductivity Meter for Laboratory

Engineered for Laboratory Accuracy and Field Mobility

Instrava Portable Digital EC Conductivity Meter integrates laboratory-grade electrochemical measurement accuracy with rugged IP65 field protection.

Designed for precise conductivity, resistivity, TDS, salinity, and temperature analysis, the instrument supports 0.000 μS/cm to 500 mS/cm ultra-wide range detection with 0.001 μS/cm minimum resolution.

With GLP-compliant data management, 1–3 point automatic calibration, selectable temperature compensation modes, and configurable cell constants, the system delivers reliable results in both controlled laboratory environments and demanding field applications.

This platform is engineered for professionals requiring precision, flexibility, and outdoor durability.

  Liquid Analysis Description  

Portable Water Digital EC Conductivity Meter Applicable Scenarios

Instrava Portable EC Meter is suitable for:

  • Laboratory water quality analysis

  • Ultrapure water monitoring systems

  • Environmental field sampling

  • Industrial process water control

  • Boiler and cooling system monitoring

  • Aquaculture and marine salinity testing

  • Wastewater treatment plants

Its IP65 structure and lithium battery system enable reliable outdoor deployment.

Conductance meter, displaying conductivity value, with control buttons.

Portable Water Digital EC Conductivity Meter Engineering Advantages

Multi-Parameter Measurement Capability

Supports:

  • Conductivity (EC)

  • Resistivity

  • Total Dissolved Solids (TDS)

  • Salinity

  • Temperature

Single-platform measurement reduces equipment redundancy in laboratory and field operations.

Ultra-Wide Conductivity Range

  • 0.000 μS/cm to 500 mS/cm

  • Resolution as low as 0.001 μS/cm

  • Accuracy: ±1.0% FS

  • Reference temperature selectable: 20°C / 25°C

Covers ultrapure water to high-salinity industrial solutions.

Advanced Temperature Compensation System

  • ATC (Automatic Temperature Compensation)

  • MTC (Manual Temperature Compensation)

  • Compensation types: None / Linear / Pure Water

Pure water compensation improves accuracy in low conductivity applications.

Flexible Calibration Architecture

  • 1–3 point calibration

  • Automatic standard recognition: 84 μS/cm, 1413 μS/cm, 12.88 mS/cm

  • Adjustable cell constant

  • Configurable temperature coefficient

  • Adjustable TDS factor

Ensures measurement consistency across diverse industrial and laboratory conditions.

Intelligent Multi-Reading Modes

  • Auto Read (Fast / Medium / Slow)

  • Timed Read

  • Continuous Read

  • Auto-Hold with endpoint lock

Reading prompts include: Reading, Stable, Locked.

Optimizes measurement workflow efficiency.

GLP-Compliant Data Management

  • 500 data sets per parameter

  • Date and time tracking

  • USB data output

  • PC and printer support

Supports traceable and structured laboratory documentation.

Rugged Field-Ready Construction

  • IP65 waterproof protection

  • 5-pin aviation conductivity connector

  • Rechargeable lithium battery

  • Adjustable auto shutdown (300–3600 sec)

  • Silicone protective case and wristband

Designed for laboratory precision and outdoor durability.

  Liquid Analysis Parameter  

Portable Water Digital EC Conductivity Meter Technical Specifications

Conductivity (EC)

ParameterSpecification
Range0.000 μS/cm – 500 mS/cm
Resolution0.001 μS/cm (minimum)
Accuracy±1.0% FS
CalibrationUp to 3 points
Standard Recognition84 μS/cm, 1413 μS/cm, 12.88 mS/cm

Resistivity

ParameterSpecification
Range5.00 Ω·cm – 20.00 MΩ·cm
Resolution0.01 Ω·cm
Accuracy±1.0% FS

TDS

ParameterSpecification
Range0.00 ppm – 300 ppt
Resolution0.01 ppm (minimum)
Accuracy±1.0% FS

Salinity

ParameterSpecification
Range0.0 – 80.0 ppt
Resolution0.1 ppt
Accuracy±2 ppt

Temperature

ParameterSpecification
Range-5 – 110°C
Unit°C / °F
Resolution0.1
Accuracy±0.2°C

System Parameters

ParameterSpecification
Display3.5-inch LCD
Data Storage500 sets per parameter
CommunicationUSB
PowerRechargeable lithium battery / AC adapter
Protection RatingIP65
Dimensions80 × 225 × 35 mm
Weight400 g

Included Accessories

  • DJS-1VTC EC Electrode

  • 1413 μS/cm EC Standard Solution (50ml)

  • Electrode Holder

  • Silicone Rubber Protective Case

  • Wristbands

  • Carrying Case

Ready for immediate laboratory or field deployment.


Designed for Professional Water Quality Control

Instrava Portable Digital EC Conductivity Meter delivers laboratory precision with field durability.

With configurable compensation modes, multi-parameter capability, and structured GLP data management, it supports professionals requiring reliable conductivity analysis across diverse industrial and environmental conditions.

Instrava — Engineered for Precision Mobility.

  Instrava OEM/ODM  

Reliable Instruments. Solutions That Fit Your Application.

Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.

By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

symbolizing trust and the beginning of a long-term partnership

  Related Product Recommendations  

In ultra-low conductivity water, ionic mobility changes non-linearly with temperature.

Standard linear compensation may introduce deviation under 10 μS/cm conditions.

Pure water compensation applies a temperature-dependent algorithm optimized for low ionic concentration solutions, improving accuracy in ultrapure water systems such as RO/DI and pharmaceutical purified water loops.

TDS is calculated from conductivity using a multiplication factor (typically 0.40–0.70).

The correct factor depends on ionic composition:

  • NaCl-dominant solutions: ~0.5

  • Natural water mixtures: ~0.65

  • Industrial process water: application-specific

Incorrect TDS factor selection leads to systematic deviation. The adjustable TDS coefficient ensures application-specific calibration alignment.

The cell constant (K) determines sensitivity range:

  • K=0.1 → low conductivity / ultrapure water

  • K=1.0 → general water testing

  • K=10 → high conductivity / brine solutions

Proper matching ensures optimal resolution and minimizes polarization effects. Adjustable cell constant configuration improves cross-application flexibility.

High-salinity solutions (>100 mS/cm) may introduce:

  • Electrode polarization

  • Temperature gradient deviation

  • Non-linear conductivity behavior

  • Incomplete temperature equilibration

Using appropriate cell constants and allowing sufficient stabilization time reduces high-range deviation.

Ultrapure water typically measures below 2 μS/cm.

At such low levels, small contamination events produce minimal conductivity change.

High resolution enables early detection of ion breakthrough in RO/EDI systems, protecting downstream industrial processes.

IP65 rating ensures:

  • Dust-tight enclosure

  • Protection against low-pressure water jets

  • Resistance to outdoor humidity and splashing

This enables stable performance in wastewater plants, cooling systems, field sampling, and industrial environments without compromising measurement integrity.

Why Choose Instrava

Built on Consistency, Not Claims

Focused on Industrial Applications

We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.

Strict Product Selection Criteria

Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.

Reliable Supply & Quality Consistency

We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.

Practical, Experience-Based Support

Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.

Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.

Industrial measurement scene showing a worker using a precision measuring instrument to measure and mark material on a workbench, demonstrating the practical application of measuring instruments in manufacturing and processing.

How to Choose the Right Liquid Analysis Solution for Industrial Applications

  • By Instrava
  • Mar 18, 2026

Selecting the right liquid analysis solution is critical for industrial process efficiency, product quality, and regulatory compliance. With multiple parameters...

  • 1Min Read

How to Optimize Maintenance and Calibration of Liquid Analysis Instruments

  • By Instrava
  • Mar 18, 2026

Effective maintenance and calibration are critical for ensuring the accuracy, reliability, and longevity of liquid analysis instruments. In industrial environments,...

  • 2Min Read

Multi-Parameter Water Quality Meter in Liquid Analysis Solutions: Integrated Monitoring for Industrial Efficiency

  • By Instrava
  • Mar 18, 2026

In modern industrial processes, monitoring multiple water quality parameters simultaneously is essential for operational efficiency, regulatory compliance, and process optimization....

  • 1Min Read
Home
Products
Whatsapp
Contact