| Rango de medición | 300–6000 mm (customizable per user requirements) |
| Precisión de la medición | ±1.5%, ±2.0% |
| Material del flotador | SS304, SS316L, HC, Ti, (customizable per user requirements) |
| Densidad media | ≥ 0.45 g/cm³ |
| Medición de interfaces | Density difference between two media ≥ 0.1 g/cm³ |
| Temperatura media | ≤ 80°C, ≤ 150°C, ≤ 250°C, ≤ 400°C |
| Media presión | Standard: ≤ 4.0 MPa; High-pressure: ≤ 42 MPa |
| Presión nominal | Standard: DN40–DN50 / PN4.0 MPa; DN80–DN100 / PN1.6 MPa High-pressure: DN40–DN50 / PN10.0 MPa Special: per customer request |
| Brida Estándar | HG20592, DIN2501, ANSI, SH, GB (or per user request) |
| Conexión a proceso | Flange DN50, G 1.5″ threaded, or per customer requirements |
| Señal de salida | 4–20 mA DC (two-wire system) |
| Resistencia a la carga | 500 Ω (powered by 24V DC) |
| Communication Protocol | HART, Modbus (RS485) |
| Salida de alarma | Upper and lower limit switch isolated output |
| Capacidad de contacto | Max. 400 VAC 0.05 A, 24 VDC 0.2 A |
| Fuente de alimentación | 15–35 VDC, 220 VAC; Lithium battery 3.6 V 7.5 Ah, 220 VAC |
| Temperatura ambiente | -20°C a +60°C |
| Material de la carcasa | SS304, SS316L, or per customer request |
| Indicator Housing | Aluminum alloy, SS304, SS316L |
| Nivel de protección | IP65, IP67 (IP68 optional upon request) |
| Clasificación antideflagrante | Intrinsically safe: Ex ia IIC T6 Ga, Isolated: Ex d IIC T6 Gb |
| Pressure Test | Tested 1.2–1.5× rated pressure per standards before delivery |