Memilih Solusi Analisis Gas Optik yang Tepat: Panduan Industri Lengkap
Selecting the right gas analysis system is crucial for ensuring safety, compliance, and efficiency across multiple industries. Optical gas analysis...
Analisis Optik
Beranda » Produk » Analisis Optik » Alat Analisis Gas Rumah Kaca - Pemantauan Presisi untuk Emisi & Optimalisasi Proses

Real-Time Greenhouse Gas Monitoring — Built for Compliance & Control
In today’s carbon-regulated industries, accurate greenhouse gas measurement is no longer optional—it’s essential.
The Instrava Curated Greenhouse Gas Analyzer is engineered for continuous, high-precision monitoring of CO₂, CH₄, N₂O, CO, and O₂, enabling industrial operators to:
Powered by patented Micro-flow NDIR dual-chamber technology (PCT/CN2018100767), this analyzer delivers:
👉 Designed for power plants, cement, steel, petrochemical, and carbon monitoring applications.
Deskripsi Analisis Optik
Advanced Multi-Gas Detection — One Analyzer, Full Visibility
Unlike conventional systems, this analyzer provides simultaneous multi-gas measurement with flexible configuration:
Measured Components:
Core Technology Advantages:
💡 Why this matters for B2B users:


Industrial-Grade Stability — Designed for Harsh Flue Gas Conditions
This analyzer is built for real industrial environments, not ideal lab conditions.
Key Performance Benefits:
Smart System Features:
👉 Ideal for:
Parameter Analisis Optik
| Parameter | Spesifikasi |
|---|---|
| Gas Terukur | CO₂, CH₄, N₂O, CO, O₂ |
| Prinsip Pengukuran | Micro-flow NDIR, Dual-beam NDIR, Electrochemical (O₂) |
| CO₂ Range | 0–500 ppm / 0–20% / 25–100% |
| CH₄ Range | 0-1000 ppm |
| N₂O Range | 0-1000 ppm |
| Rentang CO | 200–500 ppm / 1–5% |
| O₂ Range | 0–25% |
| Resolusi | Up to 1 ppm / 0.01% |
| Akurasi | ±1% F.S. (Micro-flow NDIR), ±2% F.S. |
| Pengulangan | ≤ ±1% |
| Waktu Tanggapan | T90 < 25 s |
| Laju Aliran | 0,7 - 1,2 L/menit |
| Tekanan Masuk | 2 - 50 kPa |
| Sinyal Keluaran | RS485 / RS232 / 4–20mA |
| Sample Requirement | Dust-free (≤1μm), non-condensing gas |
| Catu Daya | 100–240 VAC |
| Konsumsi Daya | 100W (stable) / 300W (max heating) |
| Diagnostik | Built-in self-diagnosis system |
Instrava OEM / ODM
Instrumen yang Dapat Diandalkan. Solusi yang Sesuai dengan Aplikasi Anda.
Instrava berfokus untuk memberikan solusi industri yang andal melalui produk yang dipilih dengan cermat, pengoptimalan berbasis aplikasi, dan penyesuaian yang fleksibel. Kami memilih instrumen yang telah terbukti dari produsen tepercaya untuk memastikan kualitas yang konsisten, mengoptimalkan solusi berdasarkan kondisi kerja nyata untuk memecahkan tantangan praktis, dan menyediakan konfigurasi yang disesuaikan untuk memenuhi kebutuhan aplikasi tertentu.
Dengan menggabungkan keahlian pemilihan dengan pemahaman aplikasi, Instrava membantu pelanggan mengurangi risiko, meningkatkan efisiensi, dan mencapai hasil yang dapat diandalkan dalam lingkungan industri yang kompleks.

What is a greenhouse gas analyzer used for in industrial applications?
A greenhouse gas analyzer is used to continuously measure emissions such as CO₂, CH₄, and N₂O in flue gas, helping industries meet environmental regulations, optimize combustion, and support carbon reporting (ESG compliance).
How does an NDIR greenhouse gas analyzer work?
NDIR (Non-Dispersive Infrared) technology detects gases by measuring infrared absorption at specific wavelengths. Advanced systems like micro-flow NDIR improve sensitivity, stability, and resistance to interference, making them ideal for low-concentration greenhouse gas detection.
Why is multi-gas monitoring important for emission control?
Simultaneous monitoring of CO₂, CH₄, N₂O, CO, and O₂ provides:
This reduces the need for multiple instruments and ensures consistent data across parameters.
What industries require greenhouse gas analyzers?
Key industries include:
These sectors require continuous emission monitoring and regulatory compliance solutions.
How accurate are modern greenhouse gas analyzers?
High-performance analyzers achieve:
This ensures reliable long-term monitoring for regulatory and operational use.
What are the advantages of micro-flow NDIR technology?
Micro-flow NDIR offers:
Ini sangat cocok untuk carbon monitoring and environmental applications.
Selecting the right gas analysis system is crucial for ensuring safety, compliance, and efficiency across multiple industries. Optical gas analysis...
Semiconductor manufacturing demands extreme precision at every stage of the process. Even trace levels of gas contamination can affect wafer...
Water and wastewater treatment facilities are increasingly required to monitor and control gas emissions—not only for regulatory compliance but also...
Dibangun di atas Konsistensi, Bukan Klaim
Kami mengkhususkan diri dalam analisis dan deteksi industri, dengan pemahaman yang jelas tentang lingkungan dan persyaratan operasi dunia nyata.
Setiap instrumen dievaluasi berdasarkan performa, stabilitas, dan kesesuaian aplikasi-bukan hanya spesifikasi atau harga.
Kami bekerja sama dengan produsen tepercaya untuk memastikan pasokan yang stabil, kualitas yang konsisten, dan pengiriman yang dapat diandalkan.
Rekomendasi kami didasarkan pada pemahaman aplikasi, membantu pelanggan menghindari masalah umum dan mencapai hasil yang dapat diandalkan.
Instrava dibuat untuk mengurangi ketidakpastian-sehingga setiap keputusan yang Anda buat menjadi lebih jelas, aman, dan dapat diandalkan.