Liquid Analysis

Digital pH Meter-High-Accuracy Digital pH, mV and Temperature Measurement for Professional Water Analysis

Engineered for Precision and Reliable Electrochemical Measurement

The Instrava Digital pH Meter is designed for accurate and stable electrochemical measurement across laboratory, industrial, and environmental applications.

With ±0.01 pH accuracy, integrated mV measurement capability, and temperature monitoring up to 100°C, the instrument provides dependable analytical performance for routine testing and critical process verification.

Compact in structure and fully digital in operation, the device ensures fast response, intuitive measurement, and reliable repeatability across diverse water quality environments.

For professionals requiring precision, stability, and operational simplicity, Instrava delivers measurement confidence.

  Liquid Analysis Description  

Digital pH Meter Applicable Scenarios

The Instrava Digital pH Meter is suitable for:

  • Industrial water quality control

  • Wastewater treatment verification

  • Laboratory analytical testing

  • Environmental monitoring and field sampling

  • Chemical process validation

  • Aquaculture and agricultural water testing

  • Educational and research laboratories

Its multi-parameter capability (pH, mV, temperature) supports both routine measurement and advanced electrochemical diagnostics.

High-quality pH meter, displaying pH value and temperature, suitable for precise measurement.
Laboratory pH meter, suitable for precise water quality analysis.

Digital pH Meter Engineering Advantages

High-Precision Digital Measurement

  • pH range: 0.00 – 14.00 pH

  • Resolution: 0.01 pH

  • Accuracy: ±0.01 pH

Delivers laboratory-grade measurement precision with stable digital processing.

Integrated mV Measurement Capability

  • mV range: -1999 – 1999 mV

  • Resolution: 1 mV

  • Accuracy: ±0.1% F.S ±1 digit

Supports ORP measurement, electrode diagnostics, and electrochemical research applications.

Wide Temperature Monitoring Range

  • Temperature range: 0 – 100°C

  • Resolution: 0.1°C

  • Accuracy: ±0.4°C

Ensures reliable measurement in variable temperature environments and supports accurate pH correction workflows.

Compact and Ergonomic Design

  • Dimensions: 123 mm × 72 mm × 33 mm

  • Lightweight and portable structure

  • Suitable for both laboratory bench use and on-site field measurement

Engineered for operational efficiency without sacrificing measurement integrity.

Stable Digital Processing

  • High-resolution display and clear readout

  • Fast response and stable data output

  • Designed for consistent repeatability in routine industrial testing

Instrava digital measurement architecture ensures reduced signal noise and improved data consistency.

  Liquid Analysis Parameter  

Digital pH Meter Technical Specifications

pH Measurement

ParameterSpecification
Range0.00 – 14.00 pH
Resolution0.01 pH
Accuracy±0.01 pH

mV Measurement

ParameterSpecification
Range-1999 – 1999 mV
Resolution1 mV
Accuracy±0.1% F.S ±1 digit

Temperature Measurement

ParameterSpecification
Range0 – 100°C
Resolution0.1°C
Accuracy±0.4°C

Physical Characteristics

ParameterSpecification
Dimensions123 mm × 72 mm × 33 mm

Designed for Professional Water Quality Control

Instrava develops reliable measurement instruments for industrial and environmental applications where data accuracy and operational stability are essential.

The Digital pH Meter combines precision, portability, and multi-parameter capability to support laboratory verification, process optimization, and regulatory compliance.

From routine testing to advanced electrochemical evaluation, Instrava ensures consistent and dependable performance.

  Instrava OEM/ODM  

Reliable Instruments. Solutions That Fit Your Application.

Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.

By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

symbolizing trust and the beginning of a long-term partnership

  Related Product Recommendations  

Electrode aging is typically indicated by:

  • Reduced slope during calibration

  • Increased stabilization time

  • Noticeable offset drift

  • Unstable readings in buffer solutions

When slope falls significantly below theoretical values (approximately 59 mV per pH at 25°C), electrode replacement should be considered to maintain ±0.01 pH accuracy.

mV drift may result from:

  • Reference junction contamination

  • Temperature fluctuations

  • Electrode dehydration

  • Electrical interference or grounding issues

Routine cleaning, proper storage in electrode solution, and stable temperature conditions help minimize drift and maintain measurement stability.

Temperature influences both:

  1. The electrode slope (Nernst response).

  2. The actual chemical equilibrium of the solution.

Without temperature correction, readings can deviate significantly, especially in high-temperature environments.
Monitoring temperature alongside pH ensures more reliable interpretation of analytical data.

For industrial environments:

  • Perform calibration before critical measurements.

  • Use at least two-point calibration for improved linearity.

  • Verify calibration daily in high-precision laboratory settings.

  • Always use fresh buffer solutions.

Consistent calibration ensures traceability and long-term measurement integrity.

Best practices include:

  • Rinse with distilled water after each measurement.

  • Store in appropriate electrode storage solution.

  • Avoid dry storage.

  • Periodically clean the junction according to application conditions.

Preventive maintenance significantly extends electrode lifespan and preserves measurement accuracy.

Yes.

The -1999 to 1999 mV measurement range supports ORP testing when paired with a compatible ORP electrode.
This expands the instrument’s functionality for oxidation-reduction potential monitoring in water treatment and chemical processes.

Why Choose Instrava

Built on Consistency, Not Claims

Focused on Industrial Applications

We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.

Strict Product Selection Criteria

Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.

Reliable Supply & Quality Consistency

We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.

Practical, Experience-Based Support

Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.

Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.

Industrial measurement scene showing a worker using a precision measuring instrument to measure and mark material on a workbench, demonstrating the practical application of measuring instruments in manufacturing and processing.

How to Choose the Right Liquid Analysis Solution for Industrial Applications

  • By Instrava
  • Mar 18, 2026

Selecting the right liquid analysis solution is critical for industrial process efficiency, product quality, and regulatory compliance. With multiple parameters...

  • 1Min Read

How to Optimize Maintenance and Calibration of Liquid Analysis Instruments

  • By Instrava
  • Mar 18, 2026

Effective maintenance and calibration are critical for ensuring the accuracy, reliability, and longevity of liquid analysis instruments. In industrial environments,...

  • 2Min Read

Multi-Parameter Water Quality Meter in Liquid Analysis Solutions: Integrated Monitoring for Industrial Efficiency

  • By Instrava
  • Mar 18, 2026

In modern industrial processes, monitoring multiple water quality parameters simultaneously is essential for operational efficiency, regulatory compliance, and process optimization....

  • 1Min Read
Home
Products
Whatsapp
Contact