How to Choose the Right Liquid Analysis Solution for Industrial Applications
Selecting the right liquid analysis solution is critical for industrial process efficiency, product quality, and regulatory compliance. With multiple parameters...
Home » Products » Liquid Analysis » Dissolved Oxygen Meter for Water

n biological treatment processes, aquaculture management, environmental compliance, and laboratory water analysis, dissolved oxygen (DO) directly determines process stability, energy efficiency, and ecological safety.
The Instrava Dissolved Oxygen Meter for Water is engineered to provide high-precision, field-ready DO measurement with dual-technology options — membrane method and optical fluorescence method — allowing engineering teams to select the optimal balance between initial investment and long-term maintenance strategy.
With large digital display, high-accuracy probe design, triple compensation (temperature, salinity, altitude), and 99-point data storage, this instrument ensures stable performance across freshwater, seawater, and variable-altitude environments.
Designed for operational reliability and field efficiency, it delivers dependable measurement performance under real industrial conditions.
Liquid Analysis Description
Dissolved Oxygen Meter Typical Application Scenarios
Municipal wastewater treatment plant aeration control
Industrial biological process monitoring
Aquaculture pond oxygen management
Environmental surface water inspection
Laboratory water quality testing
Field sampling in remote or high-altitude areas
This device supports both routine operational control and mobile compliance verification tasks.


Dissolved Oxygen Meter Engineering Advantages
Membrane Method Model
Measuring range up to 0.0–30.0 mg/L
Proven electrochemical measurement principle
Suitable for routine industrial and environmental testing
Complete accessory kit included for maintenance
Optical Fluorescence Method Model
Reduced routine maintenance
No electrolyte handling
Stable long-term performance
Ideal for users prioritizing low operational intervention
Procurement teams can select based on lifecycle cost considerations and site maintenance capabilities.
Dissolved oxygen concentration is highly influenced by environmental conditions. Instrava integrates:
Automatic Temperature Compensation (ATC)
Salinity Compensation (0–42 ppt)
Altitude Compensation (up to 3500 m for membrane model)
This ensures consistent accuracy in:
Seawater applications
Plateau regions
Variable seasonal conditions
Measurement accuracy remains stable at ±3.0% FS across operating ranges.
Large LCD screen (38 × 54 mm) with backlight
Clear numeric visualization for low-light environments
Compact handheld body (70 × 30 × 169 mm)
Approx. 3.5 m probe cable for flexible measurement positioning
Powered by 4 × AAA batteries for portable operation
Auto shut-off function improves energy efficiency during field deployment.
Manual storage of up to 99 data records
100% air saturation calibration
Temperature unit switching (°C / °F)
Suitable for:
Field documentation
Operational logs
Regulatory inspection support
Liquid Analysis Parameter
Dissolved Oxygen
Range: 0.0–30.0 mg/L
Resolution: 0.1 mg/L
Accuracy: ±3.0% FS
Calibration: 100% air saturation
Temperature
Range: -5.0–60.0°C
Resolution: 0.1°C
Accuracy: ±0.5°C
Unit: °C / °F switchable
Automatic Temperature Compensation: Supported
Compensation & Storage
Salinity Compensation: 0–42 ppt
Altitude Compensation: 0–3500 m
Data Storage: 99 manual records
Operational Parameters
LCD Size: 38 × 54 mm (Backlit)
Probe Cable Length: Approx. 3.5 m
Power Supply: 4 × AAA batteries
Auto Shut-off: 1 hour inactivity
Dimensions: 70 × 30 × 169 mm
Standard Configuration
Instrument / Probe / Membrane caps / Electrolyte / Syringe / Screwdriver / Gauze / Batteries / Manual / Certificate / Carrying case
Dissolved Oxygen
Range: 0.0–15.0 mg/L
Saturation Range: 0.0–119.9%
Resolution: 0.1 mg/L
Accuracy: ±3.0% FS
Calibration: 100% air saturation
Temperature
Range: 0.0–50.0°C
Resolution: 0.1°C
Accuracy: ±0.5°C
Unit: °C / °F switchable
Automatic Temperature Compensation: Supported
Compensation & Storage
Salinity Compensation: 0–42 ppt
Altitude Compensation: 0–1000 m
Data Storage: 99 manual records
Operational Parameters
LCD Size: 38 × 54 mm (Backlit)
Probe Cable Length: Approx. 3.5 m
Power Supply: 4 × AAA batteries
Auto Shut-off: 30 minutes inactivity
Dimensions: 70 × 30 × 169 mm
Standard Configuration
Instrument / Optical probe / AAA batteries / Manual / Certificate / Carrying case
Instrava designs portable analytical instruments with a focus on:
Measurement stability under real operating conditions
Practical compensation algorithms
Field durability
Reduced operational complexity
This dissolved oxygen meter series is optimized for engineers who require reliable field performance, predictable maintenance cycles, and measurable operational control.
Instrava OEM/ODM
Reliable Instruments. Solutions That Fit Your Application.
Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.
By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

How do we decide between membrane and fluorescence models?
From a procurement and lifecycle perspective:
Membrane model is cost-effective upfront and suitable for facilities with structured maintenance routines.
Fluorescence model reduces maintenance workload, eliminates electrolyte handling, and minimizes routine servicing.
If your operation prioritizes lower initial investment, the membrane model is appropriate.
If you prioritize long-term stability, reduced downtime, and lower maintenance intervention, the fluorescence model delivers better total cost efficiency.
How stable is the accuracy under varying field conditions?
Dissolved oxygen is influenced by temperature, salinity, and altitude. Instrava integrates:
Automatic Temperature Compensation (ATC)
Salinity compensation (0–42 ppt)
Altitude compensation (up to 3500 m depending on model)
With ±3.0% FS accuracy and 0.1 mg/L resolution, the meter maintains consistent readings across freshwater, seawater, plateau regions, and seasonal variations.
What are the maintenance requirements for the membrane model?
The membrane method requires:
Periodic membrane cap replacement
Electrolyte replenishment
Calibration after maintenance
All required accessories are included in the standard configuration.
For plants with maintenance teams already managing electrochemical sensors, integration is straightforward and predictable.
Is the fluorescence model truly lower maintenance?
Yes. The fluorescence model:
Does not require electrolyte
Does not require membrane replacement
Reduces routine maintenance frequency
Minimizes operator handling errors
For procurement managers evaluating long-term operating costs, this model typically reduces consumable expenses and labor time over the equipment lifecycle.
Is this meter suitable for aquaculture and wastewater compliance monitoring?
Yes. With measurement ranges up to 0.0–30.0 mg/L and support for % saturation readings, it is suitable for:
Aeration control in wastewater plants
Aquaculture oxygen management
Surface water environmental inspections
Laboratory validation testing
Its measurement stability supports operational optimization and compliance verification.
Does the instrument support field documentation and traceability?
The meter supports manual storage of up to 99 data records, enabling:
Field inspection reporting
Operational logging
Compliance sampling documentation
For applications requiring portable measurement without complex data systems, this functionality provides practical and efficient data retention.
Built on Consistency, Not Claims
We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.
Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.
We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.
Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.
Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.

Selecting the right liquid analysis solution is critical for industrial process efficiency, product quality, and regulatory compliance. With multiple parameters...
Effective maintenance and calibration are critical for ensuring the accuracy, reliability, and longevity of liquid analysis instruments. In industrial environments,...
In modern industrial processes, monitoring multiple water quality parameters simultaneously is essential for operational efficiency, regulatory compliance, and process optimization....