Instrava Curated Instruments presents a professional-grade Three Phase Energy Meter engineered for high-accuracy energy monitoring in complex power systems.
This UL-certified CT Type Three Phase Energy Meter supports Modbus TCP Ethernet communication, enabling real-time data access and seamless integration into modern digital energy platforms.
Designed for flexibility, it supports multiple wiring configurations and delivers full electrical parameter measurement, making it ideal for industrial, commercial, and utility-scale applications.
Key Highlights:
Applications:
Industrial Systems | Smart Buildings | Energy Management | Substations | Data Centers | Utilities
Power Monitoring & Control Description
UL Three Phase Energy Meter Core Advantages
This Three Phase Energy Meter meets strict UL standards:
Ideal for regulated and safety-critical environments
Perfect for medium and high-power applications
This CT Type Three Phase Energy Meter measures:
Provides complete system visibility
Supports solar PV and distributed generation systems
Ensures reliable energy billing and analysis
Ideal for modern industrial electrical systems


UL Three Phase Energy Meter Technical Highlights
This Modbus TCP Three Phase Energy Meter features:
Enables fast and reliable data transmission
Supports smart energy infrastructure
Adaptable to various grid structures worldwide
Suitable for diverse electrical environments
Improves user interaction and usability
Optimized for switchboards and distribution cabinets
Power Monitoring & Control Parameter
| Electrical Characteristics | ||
| Type of Measurement | RMS including harmonics on three phase AC system (3P, 3P+N) | |
| Measurement Accuracy | Voltage | ±0.5% |
| Current | ±0.5% | |
| Frequency | ±0.2% | |
| Power Factor | ±1% | |
| Active Power | ±1% | |
| Reactive Power | ±1% | |
| Apparent Power | ±1% | |
| Active Energy | Class 0.5S IEC 62053-22 | |
| Reactive Energy | Class 2 IEC62053-23 | |
| Input & Output | |||
| Input | Current
| CT Secondary | 1A/5A |
| CT Primary | 1-9999A | ||
| Min Current | 0.05A | ||
| Starting Current | 5mA | ||
| Voltage | Rated Voltage (Un) | 3 x 230/400V AC | |
| Voltage Range | 100-277V AC (L-N) 173-480V AC (L-L) | ||
| Output | SDM630MCT-TCP | Ethernet Modbus TCP | |
| Ethernet Modbus TCP Communications | |
| Communication Address | 1~247 |
| IP | 192.168.1.200 |
| Port | 502 |
| Mask | 255.255.255.0 |
| Gateway | 192.168.1.1 |
| DHCP | Off |
Instrava OEM/ODM
Reliable Instruments. Solutions That Fit Your Application.
Instrava is focused on delivering reliable industrial solutions through carefully curated products, application-driven optimization, and flexible customization. We select proven instruments from trusted manufacturers to ensure consistent quality, optimize solutions based on real working conditions to solve practical challenges, and provide tailored configurations to meet specific application needs.
By combining selection expertise with application understanding, Instrava helps customers reduce risk, improve efficiency, and achieve dependable results in complex industrial environments.

Related Product Recommendations
What is a CT Type Three Phase Energy Meter and when should you use it?
A CT Type Three Phase Energy Meter uses external current transformers to measure electrical current instead of direct connection. It is typically used when the load current exceeds the safe direct measurement range (e.g., above 100A).
This design provides:
👉 Recommended for industrial plants, substations, and large commercial buildings
What is the difference between Modbus TCP and RS485 Modbus RTU?
Both protocols are widely used in energy monitoring, but they differ significantly:
👉 Modbus TCP is preferred for modern smart energy systems and IoT platforms
How does a Three Phase Energy Meter support different wiring systems?
This meter supports multiple configurations such as 1P2W, 1P3W, 3P3W, and 3P4W, allowing it to adapt to different electrical grid structures worldwide.
This flexibility means:
Why is Class 0.5S accuracy important in energy meters?
Class 0.5S accuracy ensures that the measurement error remains very low even under varying load conditions.
This is important because:
👉 Essential for cost-sensitive and data-driven environments
Can this Three Phase Energy Meter be used in solar or renewable energy systems?
Yes. This meter supports bi-directional energy measurement, which means it can track:
This makes it ideal for:
What parameters can this multifunction energy meter measure?
This Multifunction Three Phase Energy Meter provides full electrical analysis, including:
👉 Delivers complete visibility for system performance and diagnostics
Traditional industrial instruments were not designed for cloud integration. They were built for local control systems, not for: API-based tuning...
April 2026 is not just another milestone—it marks the moment when industrial instrumentation shifts from experimentation to execution.For years, the...
Built on Consistency, Not Claims
We specialize in industrial analysis and detection, with a clear understanding of real-world operating environments and requirements.
Every instrument is evaluated based on performance, stability, and application suitability—not just specifications or pricing.
We work with trusted manufacturers to ensure stable supply, consistent quality, and dependable delivery.
Our recommendations are grounded in application understanding, helping customers avoid common issues and achieve reliable results.
Instrava is built to reduce uncertainty—so every decision you make is clearer, safer, and more reliable.